AC-PM-Media-MIB DEFINITIONS ::= BEGIN


    IMPORTS
       

        OBJECT-TYPE, 
        MODULE-IDENTITY                             FROM SNMPv2-SMI
        TAddress, 
        DisplayString, 
        DateAndTime, TEXTUAL-CONVENTION             FROM SNMPv2-TC
        IpAddress                                   FROM RFC1155-SMI
        Unsigned32,
		Integer32,
        enterprises                                 FROM SNMPv2-SMI
		SnmpAdminString								FROM SNMP-FRAMEWORK-MIB
		audioCodes,       
		acRegistrations,
		acGeneric, 
		acProducts,acBoardMibs,acPerformance		FROM AUDIOCODES-TYPES-MIB;

       
acPMMedia  MODULE-IDENTITY       
    LAST-UPDATED "201207260522Z"          --Thursday, July 26 2012
    ORGANIZATION "AudioCodes Ltd"
    CONTACT-INFO
    "Postal: Support
			 AudioCodes LTD
             1 Hayarden Street
             Airport City 
			 Lod, ISRAEL 70151
     Tel:    972-3-9764000
     Fax:    972-3-9764040
     Email:  support@audiocodes.com
     Web:    www.audiocodes.com"		
		

    DESCRIPTION       
    "The AC-PM-Media MIB offers performance monitoring
For the Media related elements in Audiocodes' devices.
The Configuration sub-tree is for configuring the interval
Period length for the entire AC-PM-Media MIB, and the 
different tables' thresholds.
The Data sub-tree presents the tables of monitored
elements.

Note  - for the entire MIB the value (-1) means the value
Asked for is either not supported or currently not relevant
(this is for when values asked for are for intervals not yet
recorded."



    ::= {acPerformance 7}  








     acPMMediaConfiguration OBJECT IDENTIFIER ::= {acPMMedia 1}


     acPMMediaConfigurationPeriodLength OBJECT-TYPE
       SYNTAX Unsigned32 (0..894780)
       MAX-ACCESS read-write
       STATUS current
       DESCRIPTION
           "Length of monitoring intervals for entire MIB.
Time is in minutes.
Access: Instant."
       ::= {acPMMediaConfiguration 1}



     acPMMediaConfigurationResetTotalCounters OBJECT-TYPE
       SYNTAX INTEGER {
                  resetCountersDone(1)
,
                  resetTotalCounters(2)

                  }
       MAX-ACCESS read-write
       STATUS current
       DESCRIPTION
           "Total-Counters Reset.  To reset the total counters, set the
value of this object to resetTotalCounters(2).
Access: Instant."
       ::= {acPMMediaConfiguration 2}



     acPMDSPAttributes OBJECT IDENTIFIER ::= {acPMMediaConfiguration 31}


     acPMDSPAttributesDSPUtilHighThreshold OBJECT-TYPE
       SYNTAX Unsigned32 (0..2147483647)
       MAX-ACCESS read-write
       STATUS current
       DESCRIPTION
           "High threshold.
Access: Instant."
       ::= {acPMDSPAttributes 1}



     acPMDSPAttributesDSPUtilLowThreshold OBJECT-TYPE
       SYNTAX Unsigned32 (0..2147483647)
       MAX-ACCESS read-write
       STATUS current
       DESCRIPTION
           "Low threshold.
Access: Instant."
       ::= {acPMDSPAttributes 2}



     acPMCodersAttributes OBJECT IDENTIFIER ::= {acPMMediaConfiguration 32}


     acPMCodersAttributesChannelsPerCoderHighThreshold OBJECT-TYPE
       SYNTAX Unsigned32 (0..2147483647)
       MAX-ACCESS read-write
       STATUS current
       DESCRIPTION
           "High threshold.
Access: Instant."
       ::= {acPMCodersAttributes 1}



     acPMCodersAttributesChannelsPerCoderLowThreshold OBJECT-TYPE
       SYNTAX Unsigned32 (0..2147483647)
       MAX-ACCESS read-write
       STATUS current
       DESCRIPTION
           "Low threshold.
Access: Instant."
       ::= {acPMCodersAttributes 2}



     acPMNetworkingAttributes OBJECT IDENTIFIER ::= {acPMMediaConfiguration 33}


     acPMNetworkingAttributesPacketDelayHighThreshold OBJECT-TYPE
       SYNTAX Unsigned32 (0..2147483647)
       MAX-ACCESS read-write
       STATUS current
       DESCRIPTION
           "High threshold.
Access: Instant."
       ::= {acPMNetworkingAttributes 1}



     acPMNetworkingAttributesPacketDelayLowThreshold OBJECT-TYPE
       SYNTAX Unsigned32 (0..2147483647)
       MAX-ACCESS read-write
       STATUS current
       DESCRIPTION
           "Low threshold.
Access: Instant."
       ::= {acPMNetworkingAttributes 2}



     acPMNetworkingAttributesPacketJitterHighThreshold OBJECT-TYPE
       SYNTAX Unsigned32 (0..2147483647)
       MAX-ACCESS read-write
       STATUS current
       DESCRIPTION
           "High threshold.
Access: Instant."
       ::= {acPMNetworkingAttributes 3}



     acPMNetworkingAttributesPacketJitterLowThreshold OBJECT-TYPE
       SYNTAX Unsigned32 (0..2147483647)
       MAX-ACCESS read-write
       STATUS current
       DESCRIPTION
           "Low threshold.
Access: Instant."
       ::= {acPMNetworkingAttributes 4}



     acPMNetworkingAttributesRTPBytesTxHighThreshold OBJECT-TYPE
       SYNTAX Unsigned32 (0..2147483647)
       MAX-ACCESS read-write
       STATUS current
       DESCRIPTION
           "High threshold.
Access: Instant."
       ::= {acPMNetworkingAttributes 5}



     acPMNetworkingAttributesRTPBytesTxLowThreshold OBJECT-TYPE
       SYNTAX Unsigned32 (0..2147483647)
       MAX-ACCESS read-write
       STATUS current
       DESCRIPTION
           "Low threshold.
Access: Instant."
       ::= {acPMNetworkingAttributes 6}



     acPMNetworkingAttributesRTPBytesRxHighThreshold OBJECT-TYPE
       SYNTAX Unsigned32 (0..2147483647)
       MAX-ACCESS read-write
       STATUS current
       DESCRIPTION
           "High threshold.
Access: Instant."
       ::= {acPMNetworkingAttributes 7}



     acPMNetworkingAttributesRTPBytesRxLowThreshold OBJECT-TYPE
       SYNTAX Unsigned32 (0..2147483647)
       MAX-ACCESS read-write
       STATUS current
       DESCRIPTION
           "Low threshold.
Access: Instant."
       ::= {acPMNetworkingAttributes 8}



     acPMNetworkingAttributesRTPPacketsTxHighThreshold OBJECT-TYPE
       SYNTAX Unsigned32 (0..2147483647)
       MAX-ACCESS read-write
       STATUS current
       DESCRIPTION
           "High threshold.
Access: Instant."
       ::= {acPMNetworkingAttributes 9}



     acPMNetworkingAttributesRTPPacketsTxLowThreshold OBJECT-TYPE
       SYNTAX Unsigned32 (0..2147483647)
       MAX-ACCESS read-write
       STATUS current
       DESCRIPTION
           "Low threshold.
Access: Instant."
       ::= {acPMNetworkingAttributes 10}



     acPMNetworkingAttributesRTPPacketsRxHighThreshold OBJECT-TYPE
       SYNTAX Unsigned32 (0..2147483647)
       MAX-ACCESS read-write
       STATUS current
       DESCRIPTION
           "High threshold.
Access: Instant."
       ::= {acPMNetworkingAttributes 11}



     acPMNetworkingAttributesRTPPacketsRxLowThreshold OBJECT-TYPE
       SYNTAX Unsigned32 (0..2147483647)
       MAX-ACCESS read-write
       STATUS current
       DESCRIPTION
           "Low threshold.
Access: Instant."
       ::= {acPMNetworkingAttributes 12}



     acPMNetworkingAttributesRTPPacketLossRxHighThreshold OBJECT-TYPE
       SYNTAX Unsigned32 (0..2147483647)
       MAX-ACCESS read-write
       STATUS current
       DESCRIPTION
           "High threshold.
Access: Instant."
       ::= {acPMNetworkingAttributes 13}



     acPMNetworkingAttributesRTPPacketLossRxLowThreshold OBJECT-TYPE
       SYNTAX Unsigned32 (0..2147483647)
       MAX-ACCESS read-write
       STATUS current
       DESCRIPTION
           "Low threshold.
Access: Instant."
       ::= {acPMNetworkingAttributes 14}



     acPMNetworkingAttributesRTPPacketLossTxHighThreshold OBJECT-TYPE
       SYNTAX Unsigned32 (0..2147483647)
       MAX-ACCESS read-write
       STATUS current
       DESCRIPTION
           "High threshold.
Access: Instant."
       ::= {acPMNetworkingAttributes 15}



     acPMNetworkingAttributesRTPPacketLossTxLowThreshold OBJECT-TYPE
       SYNTAX Unsigned32 (0..2147483647)
       MAX-ACCESS read-write
       STATUS current
       DESCRIPTION
           "Low threshold.
Access: Instant."
       ::= {acPMNetworkingAttributes 16}



     acPMNetworkingAttributesModuleRTPPacketLossRxHighThreshold OBJECT-TYPE
       SYNTAX Unsigned32 (0..2147483647)
       MAX-ACCESS read-write
       STATUS current
       DESCRIPTION
           "High threshold.
Access: Instant."
       ::= {acPMNetworkingAttributes 17}



     acPMNetworkingAttributesModuleRTPPacketLossRxLowThreshold OBJECT-TYPE
       SYNTAX Unsigned32 (0..2147483647)
       MAX-ACCESS read-write
       STATUS current
       DESCRIPTION
           "Low threshold.
Access: Instant."
       ::= {acPMNetworkingAttributes 18}



     acPMNetworkingAttributesModuleRTPPacketLossTxHighThreshold OBJECT-TYPE
       SYNTAX Unsigned32 (0..2147483647)
       MAX-ACCESS read-write
       STATUS current
       DESCRIPTION
           "High threshold.
Access: Instant."
       ::= {acPMNetworkingAttributes 19}



     acPMNetworkingAttributesModuleRTPPacketLossTxLowThreshold OBJECT-TYPE
       SYNTAX Unsigned32 (0..2147483647)
       MAX-ACCESS read-write
       STATUS current
       DESCRIPTION
           "Low threshold.
Access: Instant."
       ::= {acPMNetworkingAttributes 20}



     acPMMediaNetworkingAggregatedAttributes OBJECT IDENTIFIER ::= {acPMNetworkingAttributes 21}


     acPMMediaNetworkingAggregatedAttributesPacketDelayHighThreshold OBJECT-TYPE
       SYNTAX Unsigned32 (0..2147483647)
       MAX-ACCESS read-write
       STATUS current
       DESCRIPTION
           "High threshold.
Access: Instant."
       ::= {acPMMediaNetworkingAggregatedAttributes 1}



     acPMMediaNetworkingAggregatedAttributesPacketDelayLowThreshold OBJECT-TYPE
       SYNTAX Unsigned32 (0..2147483647)
       MAX-ACCESS read-write
       STATUS current
       DESCRIPTION
           "Low threshold.
Access: Instant."
       ::= {acPMMediaNetworkingAggregatedAttributes 2}



     acPMMediaNetworkingAggregatedAttributesPacketJitterHighThreshold OBJECT-TYPE
       SYNTAX Unsigned32 (0..2147483647)
       MAX-ACCESS read-write
       STATUS current
       DESCRIPTION
           "High threshold.
Access: Instant."
       ::= {acPMMediaNetworkingAggregatedAttributes 3}



     acPMMediaNetworkingAggregatedAttributesPacketJitterLowThreshold OBJECT-TYPE
       SYNTAX Unsigned32 (0..2147483647)
       MAX-ACCESS read-write
       STATUS current
       DESCRIPTION
           "Low threshold.
Access: Instant."
       ::= {acPMMediaNetworkingAggregatedAttributes 4}



     acPMMediaNetworkingAggregatedAttributesRTPBytesTxHighThreshold OBJECT-TYPE
       SYNTAX Unsigned32 (0..2147483647)
       MAX-ACCESS read-write
       STATUS current
       DESCRIPTION
           "High threshold.
Access: Instant."
       ::= {acPMMediaNetworkingAggregatedAttributes 5}



     acPMMediaNetworkingAggregatedAttributesRTPBytesTxLowThreshold OBJECT-TYPE
       SYNTAX Unsigned32 (0..2147483647)
       MAX-ACCESS read-write
       STATUS current
       DESCRIPTION
           "Low threshold.
Access: Instant."
       ::= {acPMMediaNetworkingAggregatedAttributes 6}



     acPMMediaNetworkingAggregatedAttributesRTPBytesRxHighThreshold OBJECT-TYPE
       SYNTAX Unsigned32 (0..2147483647)
       MAX-ACCESS read-write
       STATUS current
       DESCRIPTION
           "High threshold.
Access: Instant."
       ::= {acPMMediaNetworkingAggregatedAttributes 7}



     acPMMediaNetworkingAggregatedAttributesRTPBytesRxLowThreshold OBJECT-TYPE
       SYNTAX Unsigned32 (0..2147483647)
       MAX-ACCESS read-write
       STATUS current
       DESCRIPTION
           "Low threshold.
Access: Instant."
       ::= {acPMMediaNetworkingAggregatedAttributes 8}



     acPMMediaNetworkingAggregatedAttributesRTPPacketsTxHighThreshold OBJECT-TYPE
       SYNTAX Unsigned32 (0..2147483647)
       MAX-ACCESS read-write
       STATUS current
       DESCRIPTION
           "High threshold.
Access: Instant."
       ::= {acPMMediaNetworkingAggregatedAttributes 9}



     acPMMediaNetworkingAggregatedAttributesRTPPacketsTxLowThreshold OBJECT-TYPE
       SYNTAX Unsigned32 (0..2147483647)
       MAX-ACCESS read-write
       STATUS current
       DESCRIPTION
           "Low threshold.
Access: Instant."
       ::= {acPMMediaNetworkingAggregatedAttributes 10}



     acPMMediaNetworkingAggregatedAttributesRTPPacketsRxHighThreshold OBJECT-TYPE
       SYNTAX Unsigned32 (0..2147483647)
       MAX-ACCESS read-write
       STATUS current
       DESCRIPTION
           "High threshold.
Access: Instant."
       ::= {acPMMediaNetworkingAggregatedAttributes 11}



     acPMMediaNetworkingAggregatedAttributesRTPPacketsRxLowThreshold OBJECT-TYPE
       SYNTAX Unsigned32 (0..2147483647)
       MAX-ACCESS read-write
       STATUS current
       DESCRIPTION
           "Low threshold.
Access: Instant."
       ::= {acPMMediaNetworkingAggregatedAttributes 12}



     acPMMediaChannelUtilizationAttr OBJECT IDENTIFIER ::= {acPMMediaConfiguration 34}


     acPMMediaChannelUtilizationAttrFaxChannelsHighThreshold OBJECT-TYPE
       SYNTAX Unsigned32 (0..2147483647)
       MAX-ACCESS read-write
       STATUS current
       DESCRIPTION
           "High threshold.
Access: Instant."
       ::= {acPMMediaChannelUtilizationAttr 1}



     acPMMediaChannelUtilizationAttrFaxChannelsLowThreshold OBJECT-TYPE
       SYNTAX Unsigned32 (0..2147483647)
       MAX-ACCESS read-write
       STATUS current
       DESCRIPTION
           "Low threshold.
Access: Instant."
       ::= {acPMMediaChannelUtilizationAttr 2}



     acPMMediaChannelUtilizationAttrModemChannelsHighThreshold OBJECT-TYPE
       SYNTAX Unsigned32 (0..2147483647)
       MAX-ACCESS read-write
       STATUS current
       DESCRIPTION
           "High threshold.
Access: Instant."
       ::= {acPMMediaChannelUtilizationAttr 3}



     acPMMediaChannelUtilizationAttrModemChannelsLowThreshold OBJECT-TYPE
       SYNTAX Unsigned32 (0..2147483647)
       MAX-ACCESS read-write
       STATUS current
       DESCRIPTION
           "Low threshold.
Access: Instant."
       ::= {acPMMediaChannelUtilizationAttr 4}



     acPMMediaChannelUtilizationAttrTDM2IPChannelsHighThreshold OBJECT-TYPE
       SYNTAX Unsigned32 (0..2147483647)
       MAX-ACCESS read-write
       STATUS current
       DESCRIPTION
           "High threshold.
Access: Instant."
       ::= {acPMMediaChannelUtilizationAttr 5}



     acPMMediaChannelUtilizationAttrTDM2IPChannelsLowThreshold OBJECT-TYPE
       SYNTAX Unsigned32 (0..2147483647)
       MAX-ACCESS read-write
       STATUS current
       DESCRIPTION
           "Low threshold.
Access: Instant."
       ::= {acPMMediaChannelUtilizationAttr 6}



     acPMMediaChannelUtilizationAttrRTPStreamsHighThreshold OBJECT-TYPE
       SYNTAX Unsigned32 (0..2147483647)
       MAX-ACCESS read-write
       STATUS current
       DESCRIPTION
           "High threshold.
Access: Instant."
       ::= {acPMMediaChannelUtilizationAttr 7}



     acPMMediaChannelUtilizationAttrRTPStreamsLowThreshold OBJECT-TYPE
       SYNTAX Unsigned32 (0..2147483647)
       MAX-ACCESS read-write
       STATUS current
       DESCRIPTION
           "Low threshold.
Access: Instant."
       ::= {acPMMediaChannelUtilizationAttr 8}



     acPMMediaChannelUtilizationAttrSRTPStreamsHighThreshold OBJECT-TYPE
       SYNTAX Unsigned32 (0..2147483647)
       MAX-ACCESS read-write
       STATUS current
       DESCRIPTION
           "High threshold.
Access: Instant."
       ::= {acPMMediaChannelUtilizationAttr 9}



     acPMMediaChannelUtilizationAttrSRTPStreamsLowThreshold OBJECT-TYPE
       SYNTAX Unsigned32 (0..2147483647)
       MAX-ACCESS read-write
       STATUS current
       DESCRIPTION
           "Low threshold.
Access: Instant."
       ::= {acPMMediaChannelUtilizationAttr 10}



     acPMMediaChannelUtilizationAttrMulticastRegisChanHighThreshold OBJECT-TYPE
       SYNTAX Unsigned32 (0..2147483647)
       MAX-ACCESS read-write
       STATUS current
       DESCRIPTION
           "High threshold.
Access: Instant."
       ::= {acPMMediaChannelUtilizationAttr 11}



     acPMMediaChannelUtilizationAttrMulticastRegisChanLowThreshold OBJECT-TYPE
       SYNTAX Unsigned32 (0..2147483647)
       MAX-ACCESS read-write
       STATUS current
       DESCRIPTION
           "Low threshold.
Access: Instant."
       ::= {acPMMediaChannelUtilizationAttr 12}



     acPMMediaChannelUtilizationAttrModemRelayHighThreshold OBJECT-TYPE
       SYNTAX Unsigned32 (0..2147483647)
       MAX-ACCESS read-write
       STATUS current
       DESCRIPTION
           "High threshold.
Access: Instant."
       ::= {acPMMediaChannelUtilizationAttr 13}



     acPMMediaChannelUtilizationAttrModemRelayLowThreshold OBJECT-TYPE
       SYNTAX Unsigned32 (0..2147483647)
       MAX-ACCESS read-write
       STATUS current
       DESCRIPTION
           "Low threshold.
Access: Instant."
       ::= {acPMMediaChannelUtilizationAttr 14}



     acPMMediaData OBJECT IDENTIFIER ::= {acPMMedia 2}


     acPMMediaDataAcPMMediaTimeFromStartOfInterval OBJECT-TYPE
       SYNTAX Unsigned32 (0..2147483647)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "The time in seconds since the start of the current interval.
MIB specific."
       ::= {acPMMediaData 1}



     -- ****************************************
     -- acPMDSPUtil table declaration
     -- ****************************************
     acPMDSPUtilTable OBJECT-TYPE
       SYNTAX SEQUENCE OF AcPMDSPUtilEntry
       MAX-ACCESS not-accessible
       STATUS current
       DESCRIPTION
           "Number of active DSP channels."
       ::= {acPMMediaData 21}



     -- ****************************************
     -- acPMDSPUtil table entry
     -- ****************************************
     acPMDSPUtilEntry OBJECT-TYPE
       SYNTAX AcPMDSPUtilEntry
       MAX-ACCESS not-accessible
       STATUS current
       DESCRIPTION
           ""
       INDEX {acPMDSPUtilInterval}
       ::= {acPMDSPUtilTable 1}



     -- ****************************************
     -- acPMDSPUtil TABLE
     -- ****************************************
     AcPMDSPUtilEntry ::= SEQUENCE {
       acPMDSPUtilInterval                             Unsigned32,
       acPMDSPUtilVal                                  Gauge32,
       acPMDSPUtilAverage                              Integer32,
       acPMDSPUtilMax                                  Integer32,
       acPMDSPUtilMin                                  Integer32,
       acPMDSPUtilVolume                               Counter32,
       acPMDSPUtilTimeBelowLowThreshold                Integer32,
       acPMDSPUtilTimeBetweenThresholds                Integer32,
       acPMDSPUtilTimeAboveHighThreshold               Integer32,
       acPMDSPUtilFullDayAverage                       Integer32
     }



     acPMDSPUtilInterval OBJECT-TYPE
       SYNTAX Unsigned32 (0..2)
       MAX-ACCESS not-accessible
       STATUS current
       DESCRIPTION
           "Interval index.
0 - current period (incomplete monitoring - mid period).
1 - Last full period.
2 - One before last."
       ::= {acPMDSPUtilEntry 1}



     acPMDSPUtilVal OBJECT-TYPE
       SYNTAX Gauge32
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Value of gauge or counter."
       ::= {acPMDSPUtilEntry 2}



     acPMDSPUtilAverage OBJECT-TYPE
       SYNTAX Integer32 (-1..2147483647)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Average value with in the period time."
       ::= {acPMDSPUtilEntry 3}



     acPMDSPUtilMax OBJECT-TYPE
       SYNTAX Integer32 (-1..2147483647)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Maximum value with in the period time."
       ::= {acPMDSPUtilEntry 4}



     acPMDSPUtilMin OBJECT-TYPE
       SYNTAX Integer32 (-1..2147483647)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Minimum value with in the period time."
       ::= {acPMDSPUtilEntry 5}



     acPMDSPUtilVolume OBJECT-TYPE
       SYNTAX Counter32
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Activity volume."
       ::= {acPMDSPUtilEntry 6}



     acPMDSPUtilTimeBelowLowThreshold OBJECT-TYPE
       SYNTAX Integer32 (-1..100)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Percent of interval time for which gauge is below what was determined
as the low threshold."
       ::= {acPMDSPUtilEntry 7}



     acPMDSPUtilTimeBetweenThresholds OBJECT-TYPE
       SYNTAX Integer32 (-1..100)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Percent of interval time for which gauge is above what was determined
as the high threshold."
       ::= {acPMDSPUtilEntry 8}



     acPMDSPUtilTimeAboveHighThreshold OBJECT-TYPE
       SYNTAX Integer32 (-1..100)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Percent of interval time for which gauge is between what were
determined as the low and high thresholds."
       ::= {acPMDSPUtilEntry 9}



     acPMDSPUtilFullDayAverage OBJECT-TYPE
       SYNTAX Integer32 (-1..2147483647)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "The average of full 24 hours."
       ::= {acPMDSPUtilEntry 10}



     -- ****************************************
     -- acPMChannelsPerCoder table declaration
     -- ****************************************
     acPMChannelsPerCoderTable OBJECT-TYPE
       SYNTAX SEQUENCE OF AcPMChannelsPerCoderEntry
       MAX-ACCESS not-accessible
       STATUS current
       DESCRIPTION
           "Number of active channels per coder. Index: 0=G711, 1=G723, 2=G728, 3=G729a, 4=G729e, 5=AMR"
       ::= {acPMMediaData 22}



     -- ****************************************
     -- acPMChannelsPerCoder table entry
     -- ****************************************
     acPMChannelsPerCoderEntry OBJECT-TYPE
       SYNTAX AcPMChannelsPerCoderEntry
       MAX-ACCESS not-accessible
       STATUS current
       DESCRIPTION
           ""
       INDEX {acPMChannelsPerCoderCoders,acPMChannelsPerCoderInterval}
       ::= {acPMChannelsPerCoderTable 1}



     -- ****************************************
     -- acPMChannelsPerCoder TABLE
     -- ****************************************
     AcPMChannelsPerCoderEntry ::= SEQUENCE {
       acPMChannelsPerCoderCoders                      INTEGER,
       acPMChannelsPerCoderInterval                    Unsigned32,
       acPMChannelsPerCoderVal                         Gauge32,
       acPMChannelsPerCoderAverage                     Integer32,
       acPMChannelsPerCoderMax                         Integer32,
       acPMChannelsPerCoderMin                         Integer32,
       acPMChannelsPerCoderVolume                      Counter32,
       acPMChannelsPerCoderTimeBelowLowThreshold       Integer32,
       acPMChannelsPerCoderTimeBetweenThresholds       Integer32,
       acPMChannelsPerCoderTimeAboveHighThreshold      Integer32,
       acPMChannelsPerCoderFullDayAverage              Integer32
     }



     acPMChannelsPerCoderCoders OBJECT-TYPE
       SYNTAX INTEGER {
                  g711(0)
,
                  g723(1)
,
                  g728(2)
,
                  g729a(3)
,
                   g729e(4)
,
                  aMR(5)
,
                  g729EV(6)
,
                  eg711(7)
,
                  eVRC(8)
,
                  unknownCoder(9)
,
                  g726(10)
,
                  rTA(11)
,
                  sILK(12)
,
                  amrWB(13)
,
                  g722(14)

                  }
       MAX-ACCESS not-accessible
       STATUS current
       DESCRIPTION
           "Coder.
 0=G711, 1=G723, 2=G728, 3=G729a, 4=G729e, 5=AMR, 6=G729EV,
7=EG711, 8=EVRC, 9=Unknown Coder, 10=G726, 11=RTA, 12=SILK,
13=AMR WB, 14=G722."
       ::= {acPMChannelsPerCoderEntry 1}



     acPMChannelsPerCoderInterval OBJECT-TYPE
       SYNTAX Unsigned32 (0..2)
       MAX-ACCESS not-accessible
       STATUS current
       DESCRIPTION
           "Interval index.
0 - current period (incomplete monitoring - mid period).
1 - Last full period.
2 - One before last."
       ::= {acPMChannelsPerCoderEntry 2}



     acPMChannelsPerCoderVal OBJECT-TYPE
       SYNTAX Gauge32
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Value of gauge or counter."
       ::= {acPMChannelsPerCoderEntry 3}



     acPMChannelsPerCoderAverage OBJECT-TYPE
       SYNTAX Integer32 (-1..2147483647)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Average value with in the period time."
       ::= {acPMChannelsPerCoderEntry 4}



     acPMChannelsPerCoderMax OBJECT-TYPE
       SYNTAX Integer32 (-1..2147483647)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Maximum value with in the period time."
       ::= {acPMChannelsPerCoderEntry 5}



     acPMChannelsPerCoderMin OBJECT-TYPE
       SYNTAX Integer32 (-1..2147483647)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Minimum value with in the period time."
       ::= {acPMChannelsPerCoderEntry 6}



     acPMChannelsPerCoderVolume OBJECT-TYPE
       SYNTAX Counter32
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Activity volume."
       ::= {acPMChannelsPerCoderEntry 7}



     acPMChannelsPerCoderTimeBelowLowThreshold OBJECT-TYPE
       SYNTAX Integer32 (-1..100)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Percent of interval time for which gauge is below what was determined
as the low threshold."
       ::= {acPMChannelsPerCoderEntry 8}



     acPMChannelsPerCoderTimeBetweenThresholds OBJECT-TYPE
       SYNTAX Integer32 (-1..100)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Percent of interval time for which gauge is above what was determined
as the high threshold."
       ::= {acPMChannelsPerCoderEntry 9}



     acPMChannelsPerCoderTimeAboveHighThreshold OBJECT-TYPE
       SYNTAX Integer32 (-1..100)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Percent of interval time for which gauge is between what were
determined as the low and high thresholds."
       ::= {acPMChannelsPerCoderEntry 10}



     acPMChannelsPerCoderFullDayAverage OBJECT-TYPE
       SYNTAX Integer32 (-1..2147483647)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "The average of full 24 hours."
       ::= {acPMChannelsPerCoderEntry 11}



     -- ****************************************
     -- acPMRobustDiscard table declaration
     -- ****************************************
     acPMRobustDiscardTable OBJECT-TYPE
       SYNTAX SEQUENCE OF AcPMRobustDiscardEntry
       MAX-ACCESS not-accessible
       STATUS current
       DESCRIPTION
           "Number of packets discarded by the robust RTP filter."
       ::= {acPMMediaData 23}



     -- ****************************************
     -- acPMRobustDiscard table entry
     -- ****************************************
     acPMRobustDiscardEntry OBJECT-TYPE
       SYNTAX AcPMRobustDiscardEntry
       MAX-ACCESS not-accessible
       STATUS current
       DESCRIPTION
           ""
       INDEX {acPMRobustDiscardInterval}
       ::= {acPMRobustDiscardTable 1}



     -- ****************************************
     -- acPMRobustDiscard TABLE
     -- ****************************************
     AcPMRobustDiscardEntry ::= SEQUENCE {
       acPMRobustDiscardInterval                       Unsigned32,
       acPMRobustDiscardVal                            Counter32
     }



     acPMRobustDiscardInterval OBJECT-TYPE
       SYNTAX Unsigned32 (0..2)
       MAX-ACCESS not-accessible
       STATUS current
       DESCRIPTION
           "Interval index.
0 - current period (incomplete monitoring - mid period).
1 - Last full period.
2 - One before last."
       ::= {acPMRobustDiscardEntry 1}



     acPMRobustDiscardVal OBJECT-TYPE
       SYNTAX Counter32
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Value of gauge or counter."
       ::= {acPMRobustDiscardEntry 2}



     -- ****************************************
     -- acPMRtcpXr table declaration
     -- ****************************************
     acPMRtcpXrTable OBJECT-TYPE
       SYNTAX SEQUENCE OF AcPMRtcpXrEntry
       MAX-ACCESS not-accessible
       STATUS current
       DESCRIPTION
           "RTCP XR R-Factor"
       ::= {acPMMediaData 24}



     -- ****************************************
     -- acPMRtcpXr table entry
     -- ****************************************
     acPMRtcpXrEntry OBJECT-TYPE
       SYNTAX AcPMRtcpXrEntry
       MAX-ACCESS not-accessible
       STATUS current
       DESCRIPTION
           ""
       INDEX {acPMRtcpXrInterval}
       ::= {acPMRtcpXrTable 1}



     -- ****************************************
     -- acPMRtcpXr TABLE
     -- ****************************************
     AcPMRtcpXrEntry ::= SEQUENCE {
       acPMRtcpXrInterval                              Unsigned32,
       acPMRtcpXrAverage                               Integer32,
       acPMRtcpXrVal                                   Integer32,
       acPMRtcpXrMax                                   Integer32,
       acPMRtcpXrMin                                   Integer32
     }



     acPMRtcpXrInterval OBJECT-TYPE
       SYNTAX Unsigned32 (0..2)
       MAX-ACCESS not-accessible
       STATUS current
       DESCRIPTION
           "Interval index.
0 - current period (incomplete monitoring - mid period).
1 - Last full period.
2 - One before last."
       ::= {acPMRtcpXrEntry 1}



     acPMRtcpXrAverage OBJECT-TYPE
       SYNTAX Integer32 (-1..2147483647)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Average value within the period time."
       ::= {acPMRtcpXrEntry 2}



     acPMRtcpXrVal OBJECT-TYPE
       SYNTAX Integer32 (-1..2147483647)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Value of gauge or counter."
       ::= {acPMRtcpXrEntry 3}



     acPMRtcpXrMax OBJECT-TYPE
       SYNTAX Integer32 (-1..2147483647)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Maximum value within the period time."
       ::= {acPMRtcpXrEntry 4}



     acPMRtcpXrMin OBJECT-TYPE
       SYNTAX Integer32 (-1..2147483647)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Minimum value within the period time."
       ::= {acPMRtcpXrEntry 5}



     acPMMediaNetworking OBJECT IDENTIFIER ::= {acPMMediaData 31}


     -- ****************************************
     -- acPMPacketDelay table declaration
     -- ****************************************
     acPMPacketDelayTable OBJECT-TYPE
       SYNTAX SEQUENCE OF AcPMPacketDelayEntry
       MAX-ACCESS not-accessible
       STATUS current
       DESCRIPTION
           "Packet delay in RTCP data, per trunk."
       ::= {acPMMediaNetworking 1}



     -- ****************************************
     -- acPMPacketDelay table entry
     -- ****************************************
     acPMPacketDelayEntry OBJECT-TYPE
       SYNTAX AcPMPacketDelayEntry
       MAX-ACCESS not-accessible
       STATUS current
       DESCRIPTION
           ""
       INDEX {acPMPacketDelayTrunkNum,acPMPacketDelayInterval}
       ::= {acPMPacketDelayTable 1}



     -- ****************************************
     -- acPMPacketDelay TABLE
     -- ****************************************
     AcPMPacketDelayEntry ::= SEQUENCE {
       acPMPacketDelayTrunkNum                         Unsigned32,
       acPMPacketDelayInterval                         Unsigned32,
       acPMPacketDelayVal                              Gauge32,
       acPMPacketDelayAverage                          Integer32,
       acPMPacketDelayMax                              Integer32,
       acPMPacketDelayMin                              Integer32,
       acPMPacketDelayVolume                           Counter32,
       acPMPacketDelayTimeBelowLowThreshold            Integer32,
       acPMPacketDelayTimeBetweenThresholds            Integer32,
       acPMPacketDelayTimeAboveHighThreshold           Integer32,
       acPMPacketDelayFullDayAverage                   Integer32
     }



     acPMPacketDelayTrunkNum OBJECT-TYPE
       SYNTAX Unsigned32 (0..83)
       MAX-ACCESS not-accessible
       STATUS current
       DESCRIPTION
           "Trunk number.
0 is the first trunk."
       ::= {acPMPacketDelayEntry 1}



     acPMPacketDelayInterval OBJECT-TYPE
       SYNTAX Unsigned32 (0..2)
       MAX-ACCESS not-accessible
       STATUS current
       DESCRIPTION
           "Interval index.
0 - current period (incomplete monitoring - mid period).
1 - Last full period.
2 - One before last."
       ::= {acPMPacketDelayEntry 2}



     acPMPacketDelayVal OBJECT-TYPE
       SYNTAX Gauge32
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Value of gauge or counter."
       ::= {acPMPacketDelayEntry 3}



     acPMPacketDelayAverage OBJECT-TYPE
       SYNTAX Integer32 (-1..2147483647)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Average value with in the period time."
       ::= {acPMPacketDelayEntry 4}



     acPMPacketDelayMax OBJECT-TYPE
       SYNTAX Integer32 (-1..2147483647)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Maximum value with in the period time."
       ::= {acPMPacketDelayEntry 5}



     acPMPacketDelayMin OBJECT-TYPE
       SYNTAX Integer32 (-1..2147483647)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Minimum value with in the period time."
       ::= {acPMPacketDelayEntry 6}



     acPMPacketDelayVolume OBJECT-TYPE
       SYNTAX Counter32
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Activity volume."
       ::= {acPMPacketDelayEntry 7}



     acPMPacketDelayTimeBelowLowThreshold OBJECT-TYPE
       SYNTAX Integer32 (-1..100)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Percent of interval time for which gauge is below what was determined
as the low threshold."
       ::= {acPMPacketDelayEntry 8}



     acPMPacketDelayTimeBetweenThresholds OBJECT-TYPE
       SYNTAX Integer32 (-1..100)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Percent of interval time for which gauge is above what was determined
as the high threshold."
       ::= {acPMPacketDelayEntry 9}



     acPMPacketDelayTimeAboveHighThreshold OBJECT-TYPE
       SYNTAX Integer32 (-1..100)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Percent of interval time for which gauge is between what were
determined as the low and high thresholds."
       ::= {acPMPacketDelayEntry 10}



     acPMPacketDelayFullDayAverage OBJECT-TYPE
       SYNTAX Integer32 (-1..2147483647)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "The average of full 24 hours."
       ::= {acPMPacketDelayEntry 11}



     -- ****************************************
     -- acPMPacketJitter table declaration
     -- ****************************************
     acPMPacketJitterTable OBJECT-TYPE
       SYNTAX SEQUENCE OF AcPMPacketJitterEntry
       MAX-ACCESS not-accessible
       STATUS current
       DESCRIPTION
           "Packet jitter in RTCP data, per trunk."
       ::= {acPMMediaNetworking 2}



     -- ****************************************
     -- acPMPacketJitter table entry
     -- ****************************************
     acPMPacketJitterEntry OBJECT-TYPE
       SYNTAX AcPMPacketJitterEntry
       MAX-ACCESS not-accessible
       STATUS current
       DESCRIPTION
           ""
       INDEX {acPMPacketJitterTrunkNum,acPMPacketJitterInterval}
       ::= {acPMPacketJitterTable 1}



     -- ****************************************
     -- acPMPacketJitter TABLE
     -- ****************************************
     AcPMPacketJitterEntry ::= SEQUENCE {
       acPMPacketJitterTrunkNum                        Unsigned32,
       acPMPacketJitterInterval                        Unsigned32,
       acPMPacketJitterVal                             Gauge32,
       acPMPacketJitterAverage                         Integer32,
       acPMPacketJitterMax                             Integer32,
       acPMPacketJitterMin                             Integer32,
       acPMPacketJitterVolume                          Counter32,
       acPMPacketJitterTimeBelowLowThreshold           Integer32,
       acPMPacketJitterTimeBetweenThresholds           Integer32,
       acPMPacketJitterTimeAboveHighThreshold          Integer32,
       acPMPacketJitterFullDayAverage                  Integer32
     }



     acPMPacketJitterTrunkNum OBJECT-TYPE
       SYNTAX Unsigned32 (0..83)
       MAX-ACCESS not-accessible
       STATUS current
       DESCRIPTION
           "Trunk number.
0 is the first trunk."
       ::= {acPMPacketJitterEntry 1}



     acPMPacketJitterInterval OBJECT-TYPE
       SYNTAX Unsigned32 (0..2)
       MAX-ACCESS not-accessible
       STATUS current
       DESCRIPTION
           "Interval index.
0 - current period (incomplete monitoring - mid period).
1 - Last full period.
2 - One before last."
       ::= {acPMPacketJitterEntry 2}



     acPMPacketJitterVal OBJECT-TYPE
       SYNTAX Gauge32
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Value of gauge or counter."
       ::= {acPMPacketJitterEntry 3}



     acPMPacketJitterAverage OBJECT-TYPE
       SYNTAX Integer32 (-1..2147483647)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Average value with in the period time."
       ::= {acPMPacketJitterEntry 4}



     acPMPacketJitterMax OBJECT-TYPE
       SYNTAX Integer32 (-1..2147483647)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Maximum value with in the period time."
       ::= {acPMPacketJitterEntry 5}



     acPMPacketJitterMin OBJECT-TYPE
       SYNTAX Integer32 (-1..2147483647)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Minimum value with in the period time."
       ::= {acPMPacketJitterEntry 6}



     acPMPacketJitterVolume OBJECT-TYPE
       SYNTAX Counter32
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Activity volume."
       ::= {acPMPacketJitterEntry 7}



     acPMPacketJitterTimeBelowLowThreshold OBJECT-TYPE
       SYNTAX Integer32 (-1..100)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Percent of interval time for which gauge is below what was determined
as the low threshold."
       ::= {acPMPacketJitterEntry 8}



     acPMPacketJitterTimeBetweenThresholds OBJECT-TYPE
       SYNTAX Integer32 (-1..100)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Percent of interval time for which gauge is above what was determined
as the high threshold."
       ::= {acPMPacketJitterEntry 9}



     acPMPacketJitterTimeAboveHighThreshold OBJECT-TYPE
       SYNTAX Integer32 (-1..100)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Percent of interval time for which gauge is between what were
determined as the low and high thresholds."
       ::= {acPMPacketJitterEntry 10}



     acPMPacketJitterFullDayAverage OBJECT-TYPE
       SYNTAX Integer32 (-1..2147483647)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "The average of full 24 hours."
       ::= {acPMPacketJitterEntry 11}



     -- ****************************************
     -- acPMRTPBytesTx table declaration
     -- ****************************************
     acPMRTPBytesTxTable OBJECT-TYPE
       SYNTAX SEQUENCE OF AcPMRTPBytesTxEntry
       MAX-ACCESS not-accessible
       STATUS current
       DESCRIPTION
           "RTP bytes sent in RTCP data, per trunk."
       ::= {acPMMediaNetworking 3}



     -- ****************************************
     -- acPMRTPBytesTx table entry
     -- ****************************************
     acPMRTPBytesTxEntry OBJECT-TYPE
       SYNTAX AcPMRTPBytesTxEntry
       MAX-ACCESS not-accessible
       STATUS current
       DESCRIPTION
           ""
       INDEX {acPMRTPBytesTxTrunkNum,acPMRTPBytesTxInterval}
       ::= {acPMRTPBytesTxTable 1}



     -- ****************************************
     -- acPMRTPBytesTx TABLE
     -- ****************************************
     AcPMRTPBytesTxEntry ::= SEQUENCE {
       acPMRTPBytesTxTrunkNum                          Unsigned32,
       acPMRTPBytesTxInterval                          Unsigned32,
       acPMRTPBytesTxVal                               Gauge32,
       acPMRTPBytesTxAverage                           Integer32,
       acPMRTPBytesTxMax                               Integer32,
       acPMRTPBytesTxMin                               Integer32,
       acPMRTPBytesTxVolume                            Counter32,
       acPMRTPBytesTxTimeBelowLowThreshold             Integer32,
       acPMRTPBytesTxTimeBetweenThresholds             Integer32,
       acPMRTPBytesTxTimeAboveHighThreshold            Integer32,
       acPMRTPBytesTxFullDayAverage                    Integer32
     }



     acPMRTPBytesTxTrunkNum OBJECT-TYPE
       SYNTAX Unsigned32 (0..83)
       MAX-ACCESS not-accessible
       STATUS current
       DESCRIPTION
           "Trunk number.
0 is the first trunk."
       ::= {acPMRTPBytesTxEntry 1}



     acPMRTPBytesTxInterval OBJECT-TYPE
       SYNTAX Unsigned32 (0..2)
       MAX-ACCESS not-accessible
       STATUS current
       DESCRIPTION
           "Interval index.
0 - current period (incomplete monitoring - mid period).
1 - Last full period.
2 - One before last."
       ::= {acPMRTPBytesTxEntry 2}



     acPMRTPBytesTxVal OBJECT-TYPE
       SYNTAX Gauge32
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Value of gauge or counter."
       ::= {acPMRTPBytesTxEntry 3}



     acPMRTPBytesTxAverage OBJECT-TYPE
       SYNTAX Integer32 (-1..2147483647)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Average value with in the period time."
       ::= {acPMRTPBytesTxEntry 4}



     acPMRTPBytesTxMax OBJECT-TYPE
       SYNTAX Integer32 (-1..2147483647)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Maximum value with in the period time."
       ::= {acPMRTPBytesTxEntry 5}



     acPMRTPBytesTxMin OBJECT-TYPE
       SYNTAX Integer32 (-1..2147483647)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Minimum value with in the period time."
       ::= {acPMRTPBytesTxEntry 6}



     acPMRTPBytesTxVolume OBJECT-TYPE
       SYNTAX Counter32
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Activity volume."
       ::= {acPMRTPBytesTxEntry 7}



     acPMRTPBytesTxTimeBelowLowThreshold OBJECT-TYPE
       SYNTAX Integer32 (-1..100)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Percent of interval time for which counter is below what was
determined as the low threshold."
       ::= {acPMRTPBytesTxEntry 8}



     acPMRTPBytesTxTimeBetweenThresholds OBJECT-TYPE
       SYNTAX Integer32 (-1..100)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Percent of interval time for which counter is above what was
determined as the high threshold."
       ::= {acPMRTPBytesTxEntry 9}



     acPMRTPBytesTxTimeAboveHighThreshold OBJECT-TYPE
       SYNTAX Integer32 (-1..100)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Percent of interval time for which counter is between what were
determined as the low and high thresholds."
       ::= {acPMRTPBytesTxEntry 10}



     acPMRTPBytesTxFullDayAverage OBJECT-TYPE
       SYNTAX Integer32 (-1..2147483647)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "The average of full 24 hours."
       ::= {acPMRTPBytesTxEntry 11}



     -- ****************************************
     -- acPMRTPBytesRx table declaration
     -- ****************************************
     acPMRTPBytesRxTable OBJECT-TYPE
       SYNTAX SEQUENCE OF AcPMRTPBytesRxEntry
       MAX-ACCESS not-accessible
       STATUS current
       DESCRIPTION
           "RTP bytes received in RTCP data, per trunk."
       ::= {acPMMediaNetworking 4}



     -- ****************************************
     -- acPMRTPBytesRx table entry
     -- ****************************************
     acPMRTPBytesRxEntry OBJECT-TYPE
       SYNTAX AcPMRTPBytesRxEntry
       MAX-ACCESS not-accessible
       STATUS current
       DESCRIPTION
           ""
       INDEX {acPMRTPBytesRxTrunkNum,acPMRTPBytesRxInterval}
       ::= {acPMRTPBytesRxTable 1}



     -- ****************************************
     -- acPMRTPBytesRx TABLE
     -- ****************************************
     AcPMRTPBytesRxEntry ::= SEQUENCE {
       acPMRTPBytesRxTrunkNum                          Unsigned32,
       acPMRTPBytesRxInterval                          Unsigned32,
       acPMRTPBytesRxVal                               Gauge32,
       acPMRTPBytesRxAverage                           Integer32,
       acPMRTPBytesRxMax                               Integer32,
       acPMRTPBytesRxMin                               Integer32,
       acPMRTPBytesRxVolume                            Counter32,
       acPMRTPBytesRxTimeBelowLowThreshold             Integer32,
       acPMRTPBytesRxTimeBetweenThresholds             Integer32,
       acPMRTPBytesRxTimeAboveHighThreshold            Integer32,
       acPMRTPBytesRxFullDayAverage                    Integer32
     }



     acPMRTPBytesRxTrunkNum OBJECT-TYPE
       SYNTAX Unsigned32 (0..83)
       MAX-ACCESS not-accessible
       STATUS current
       DESCRIPTION
           "Trunk number.
0 is the first trunk."
       ::= {acPMRTPBytesRxEntry 1}



     acPMRTPBytesRxInterval OBJECT-TYPE
       SYNTAX Unsigned32 (0..2)
       MAX-ACCESS not-accessible
       STATUS current
       DESCRIPTION
           "Interval index.
0 - current period (incomplete monitoring - mid period).
1 - Last full period.
2 - One before last."
       ::= {acPMRTPBytesRxEntry 2}



     acPMRTPBytesRxVal OBJECT-TYPE
       SYNTAX Gauge32
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Value of gauge or counter."
       ::= {acPMRTPBytesRxEntry 3}



     acPMRTPBytesRxAverage OBJECT-TYPE
       SYNTAX Integer32 (-1..2147483647)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Average value with in the period time."
       ::= {acPMRTPBytesRxEntry 4}



     acPMRTPBytesRxMax OBJECT-TYPE
       SYNTAX Integer32 (-1..2147483647)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Maximum value with in the period time."
       ::= {acPMRTPBytesRxEntry 5}



     acPMRTPBytesRxMin OBJECT-TYPE
       SYNTAX Integer32 (-1..2147483647)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Minimum value with in the period time."
       ::= {acPMRTPBytesRxEntry 6}



     acPMRTPBytesRxVolume OBJECT-TYPE
       SYNTAX Counter32
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Activity volume."
       ::= {acPMRTPBytesRxEntry 7}



     acPMRTPBytesRxTimeBelowLowThreshold OBJECT-TYPE
       SYNTAX Integer32 (-1..100)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Percent of interval time for which counter is below what was
determined as the low threshold."
       ::= {acPMRTPBytesRxEntry 8}



     acPMRTPBytesRxTimeBetweenThresholds OBJECT-TYPE
       SYNTAX Integer32 (-1..100)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Percent of interval time for which counter is above what was
determined as the high threshold."
       ::= {acPMRTPBytesRxEntry 9}



     acPMRTPBytesRxTimeAboveHighThreshold OBJECT-TYPE
       SYNTAX Integer32 (-1..100)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Percent of interval time for which counter is between what were
determined as the low and high thresholds."
       ::= {acPMRTPBytesRxEntry 10}



     acPMRTPBytesRxFullDayAverage OBJECT-TYPE
       SYNTAX Integer32 (-1..2147483647)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "The average of full 24 hours."
       ::= {acPMRTPBytesRxEntry 11}



     -- ****************************************
     -- acPMRTPPacketsTx table declaration
     -- ****************************************
     acPMRTPPacketsTxTable OBJECT-TYPE
       SYNTAX SEQUENCE OF AcPMRTPPacketsTxEntry
       MAX-ACCESS not-accessible
       STATUS current
       DESCRIPTION
           "RTP packets sent in RTCP data, per trunk."
       ::= {acPMMediaNetworking 5}



     -- ****************************************
     -- acPMRTPPacketsTx table entry
     -- ****************************************
     acPMRTPPacketsTxEntry OBJECT-TYPE
       SYNTAX AcPMRTPPacketsTxEntry
       MAX-ACCESS not-accessible
       STATUS current
       DESCRIPTION
           ""
       INDEX {acPMRTPPacketsTxTrunkNum,acPMRTPPacketsTxInterval}
       ::= {acPMRTPPacketsTxTable 1}



     -- ****************************************
     -- acPMRTPPacketsTx TABLE
     -- ****************************************
     AcPMRTPPacketsTxEntry ::= SEQUENCE {
       acPMRTPPacketsTxTrunkNum                        Unsigned32,
       acPMRTPPacketsTxInterval                        Unsigned32,
       acPMRTPPacketsTxVal                             Gauge32,
       acPMRTPPacketsTxAverage                         Integer32,
       acPMRTPPacketsTxMax                             Integer32,
       acPMRTPPacketsTxMin                             Integer32,
       acPMRTPPacketsTxVolume                          Counter32,
       acPMRTPPacketsTxTimeBelowLowThreshold           Integer32,
       acPMRTPPacketsTxTimeBetweenThresholds           Integer32,
       acPMRTPPacketsTxTimeAboveHighThreshold          Integer32,
       acPMRTPPacketsTxFullDayAverage                  Integer32,
       acPMRTPPacketsTxTotal                           Integer32
     }



     acPMRTPPacketsTxTrunkNum OBJECT-TYPE
       SYNTAX Unsigned32 (0..83)
       MAX-ACCESS not-accessible
       STATUS current
       DESCRIPTION
           "Trunk number.
0 is the first trunk."
       ::= {acPMRTPPacketsTxEntry 1}



     acPMRTPPacketsTxInterval OBJECT-TYPE
       SYNTAX Unsigned32 (0..2)
       MAX-ACCESS not-accessible
       STATUS current
       DESCRIPTION
           "Interval index.
0 - current period (incomplete monitoring - mid period).
1 - Last full period.
2 - One before last."
       ::= {acPMRTPPacketsTxEntry 2}



     acPMRTPPacketsTxVal OBJECT-TYPE
       SYNTAX Gauge32
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Value of gauge or counter."
       ::= {acPMRTPPacketsTxEntry 3}



     acPMRTPPacketsTxAverage OBJECT-TYPE
       SYNTAX Integer32 (-1..2147483647)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Average value with in the period time."
       ::= {acPMRTPPacketsTxEntry 4}



     acPMRTPPacketsTxMax OBJECT-TYPE
       SYNTAX Integer32 (-1..2147483647)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Maximum value with in the period time."
       ::= {acPMRTPPacketsTxEntry 5}



     acPMRTPPacketsTxMin OBJECT-TYPE
       SYNTAX Integer32 (-1..2147483647)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Minimum value with in the period time."
       ::= {acPMRTPPacketsTxEntry 6}



     acPMRTPPacketsTxVolume OBJECT-TYPE
       SYNTAX Counter32
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Activity volume."
       ::= {acPMRTPPacketsTxEntry 7}



     acPMRTPPacketsTxTimeBelowLowThreshold OBJECT-TYPE
       SYNTAX Integer32 (-1..100)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Percent of interval time for which counter is below what was
determined as the low threshold."
       ::= {acPMRTPPacketsTxEntry 8}



     acPMRTPPacketsTxTimeBetweenThresholds OBJECT-TYPE
       SYNTAX Integer32 (-1..100)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Percent of interval time for which counter is above what was
determined as the high threshold."
       ::= {acPMRTPPacketsTxEntry 9}



     acPMRTPPacketsTxTimeAboveHighThreshold OBJECT-TYPE
       SYNTAX Integer32 (-1..100)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Percent of interval time for which counter is between what were
determined as the low and high thresholds."
       ::= {acPMRTPPacketsTxEntry 10}



     acPMRTPPacketsTxFullDayAverage OBJECT-TYPE
       SYNTAX Integer32 (-1..2147483647)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "The average of full 24 hours."
       ::= {acPMRTPPacketsTxEntry 11}



     acPMRTPPacketsTxTotal OBJECT-TYPE
       SYNTAX Integer32 (-1..2147483647)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Total since last reset."
       ::= {acPMRTPPacketsTxEntry 12}



     -- ****************************************
     -- acPMRTPPacketsRx table declaration
     -- ****************************************
     acPMRTPPacketsRxTable OBJECT-TYPE
       SYNTAX SEQUENCE OF AcPMRTPPacketsRxEntry
       MAX-ACCESS not-accessible
       STATUS current
       DESCRIPTION
           "RTP packets received in RTCP data, per trunk."
       ::= {acPMMediaNetworking 6}



     -- ****************************************
     -- acPMRTPPacketsRx table entry
     -- ****************************************
     acPMRTPPacketsRxEntry OBJECT-TYPE
       SYNTAX AcPMRTPPacketsRxEntry
       MAX-ACCESS not-accessible
       STATUS current
       DESCRIPTION
           ""
       INDEX {acPMRTPPacketsRxTrunkNum,acPMRTPPacketsRxInterval}
       ::= {acPMRTPPacketsRxTable 1}



     -- ****************************************
     -- acPMRTPPacketsRx TABLE
     -- ****************************************
     AcPMRTPPacketsRxEntry ::= SEQUENCE {
       acPMRTPPacketsRxTrunkNum                        Unsigned32,
       acPMRTPPacketsRxInterval                        Unsigned32,
       acPMRTPPacketsRxVal                             Gauge32,
       acPMRTPPacketsRxAverage                         Integer32,
       acPMRTPPacketsRxMax                             Integer32,
       acPMRTPPacketsRxMin                             Integer32,
       acPMRTPPacketsRxVolume                          Counter32,
       acPMRTPPacketsRxTimeBelowLowThreshold           Integer32,
       acPMRTPPacketsRxTimeBetweenThresholds           Integer32,
       acPMRTPPacketsRxTimeAboveHighThreshold          Integer32,
       acPMRTPPacketsRxFullDayAverage                  Integer32,
       acPMRTPPacketsRxTotal                           Integer32
     }



     acPMRTPPacketsRxTrunkNum OBJECT-TYPE
       SYNTAX Unsigned32 (0..83)
       MAX-ACCESS not-accessible
       STATUS current
       DESCRIPTION
           "Trunk number.
0 is the first trunk."
       ::= {acPMRTPPacketsRxEntry 1}



     acPMRTPPacketsRxInterval OBJECT-TYPE
       SYNTAX Unsigned32 (0..2)
       MAX-ACCESS not-accessible
       STATUS current
       DESCRIPTION
           "Interval index.
0 - current period (incomplete monitoring - mid period).
1 - Last full period.
2 - One before last."
       ::= {acPMRTPPacketsRxEntry 2}



     acPMRTPPacketsRxVal OBJECT-TYPE
       SYNTAX Gauge32
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Value of gauge or counter."
       ::= {acPMRTPPacketsRxEntry 3}



     acPMRTPPacketsRxAverage OBJECT-TYPE
       SYNTAX Integer32 (-1..2147483647)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Average value with in the period time."
       ::= {acPMRTPPacketsRxEntry 4}



     acPMRTPPacketsRxMax OBJECT-TYPE
       SYNTAX Integer32 (-1..2147483647)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Maximum value with in the period time."
       ::= {acPMRTPPacketsRxEntry 5}



     acPMRTPPacketsRxMin OBJECT-TYPE
       SYNTAX Integer32 (-1..2147483647)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Minimum value with in the period time."
       ::= {acPMRTPPacketsRxEntry 6}



     acPMRTPPacketsRxVolume OBJECT-TYPE
       SYNTAX Counter32
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Activity volume."
       ::= {acPMRTPPacketsRxEntry 7}



     acPMRTPPacketsRxTimeBelowLowThreshold OBJECT-TYPE
       SYNTAX Integer32 (-1..100)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Percent of interval time for which counter is below what was
determined as the low threshold."
       ::= {acPMRTPPacketsRxEntry 8}



     acPMRTPPacketsRxTimeBetweenThresholds OBJECT-TYPE
       SYNTAX Integer32 (-1..100)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Percent of interval time for which counter is above what was
determined as the high threshold."
       ::= {acPMRTPPacketsRxEntry 9}



     acPMRTPPacketsRxTimeAboveHighThreshold OBJECT-TYPE
       SYNTAX Integer32 (-1..100)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Percent of interval time for which counter is between what were
determined as the low and high thresholds."
       ::= {acPMRTPPacketsRxEntry 10}



     acPMRTPPacketsRxFullDayAverage OBJECT-TYPE
       SYNTAX Integer32 (-1..2147483647)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "The average of full 24 hours."
       ::= {acPMRTPPacketsRxEntry 11}



     acPMRTPPacketsRxTotal OBJECT-TYPE
       SYNTAX Integer32 (-1..2147483647)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Total since last reset."
       ::= {acPMRTPPacketsRxEntry 12}



     -- ****************************************
     -- acPMRTPPacketLossRx table declaration
     -- ****************************************
     acPMRTPPacketLossRxTable OBJECT-TYPE
       SYNTAX SEQUENCE OF AcPMRTPPacketLossRxEntry
       MAX-ACCESS not-accessible
       STATUS current
       DESCRIPTION
           "RTP packet loss reported in outgoing RTCP data, per trunk."
       ::= {acPMMediaNetworking 7}



     -- ****************************************
     -- acPMRTPPacketLossRx table entry
     -- ****************************************
     acPMRTPPacketLossRxEntry OBJECT-TYPE
       SYNTAX AcPMRTPPacketLossRxEntry
       MAX-ACCESS not-accessible
       STATUS current
       DESCRIPTION
           ""
       INDEX {acPMRTPPacketLossRxTrunkNum,acPMRTPPacketLossRxInterval}
       ::= {acPMRTPPacketLossRxTable 1}



     -- ****************************************
     -- acPMRTPPacketLossRx TABLE
     -- ****************************************
     AcPMRTPPacketLossRxEntry ::= SEQUENCE {
       acPMRTPPacketLossRxTrunkNum                     Unsigned32,
       acPMRTPPacketLossRxInterval                     Unsigned32,
       acPMRTPPacketLossRxVal                          Gauge32,
       acPMRTPPacketLossRxAverage                      Integer32,
       acPMRTPPacketLossRxMax                          Integer32,
       acPMRTPPacketLossRxMin                          Integer32,
       acPMRTPPacketLossRxVolume                       Counter32,
       acPMRTPPacketLossRxTimeBelowLowThreshold        Integer32,
       acPMRTPPacketLossRxTimeBetweenThresholds        Integer32,
       acPMRTPPacketLossRxTimeAboveHighThreshold       Integer32,
       acPMRTPPacketLossRxFullDayAverage               Integer32
     }



     acPMRTPPacketLossRxTrunkNum OBJECT-TYPE
       SYNTAX Unsigned32 (0..83)
       MAX-ACCESS not-accessible
       STATUS current
       DESCRIPTION
           "Trunk number.
0 is the first trunk."
       ::= {acPMRTPPacketLossRxEntry 1}



     acPMRTPPacketLossRxInterval OBJECT-TYPE
       SYNTAX Unsigned32 (0..2)
       MAX-ACCESS not-accessible
       STATUS current
       DESCRIPTION
           "Interval index.
0 - current period (incomplete monitoring - mid period).
1 - Last full period.
2 - One before last."
       ::= {acPMRTPPacketLossRxEntry 2}



     acPMRTPPacketLossRxVal OBJECT-TYPE
       SYNTAX Gauge32
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Value of gauge or counter."
       ::= {acPMRTPPacketLossRxEntry 3}



     acPMRTPPacketLossRxAverage OBJECT-TYPE
       SYNTAX Integer32 (-1..2147483647)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Average value with in the period time."
       ::= {acPMRTPPacketLossRxEntry 4}



     acPMRTPPacketLossRxMax OBJECT-TYPE
       SYNTAX Integer32 (-1..2147483647)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Maximum value with in the period time."
       ::= {acPMRTPPacketLossRxEntry 5}



     acPMRTPPacketLossRxMin OBJECT-TYPE
       SYNTAX Integer32 (-1..2147483647)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Minimum value with in the period time."
       ::= {acPMRTPPacketLossRxEntry 6}



     acPMRTPPacketLossRxVolume OBJECT-TYPE
       SYNTAX Counter32
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Activity volume."
       ::= {acPMRTPPacketLossRxEntry 7}



     acPMRTPPacketLossRxTimeBelowLowThreshold OBJECT-TYPE
       SYNTAX Integer32 (-1..100)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Percent of interval time for which gauge is below what was determined
as the low threshold."
       ::= {acPMRTPPacketLossRxEntry 8}



     acPMRTPPacketLossRxTimeBetweenThresholds OBJECT-TYPE
       SYNTAX Integer32 (-1..100)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Percent of interval time for which gauge is above what was determined
as the high threshold."
       ::= {acPMRTPPacketLossRxEntry 9}



     acPMRTPPacketLossRxTimeAboveHighThreshold OBJECT-TYPE
       SYNTAX Integer32 (-1..100)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Percent of interval time for which gauge is between what were
determined as the low and high thresholds."
       ::= {acPMRTPPacketLossRxEntry 10}



     acPMRTPPacketLossRxFullDayAverage OBJECT-TYPE
       SYNTAX Integer32 (-1..2147483647)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "The average of full 24 hours."
       ::= {acPMRTPPacketLossRxEntry 11}



     -- ****************************************
     -- acPMRTPPacketLossTx table declaration
     -- ****************************************
     acPMRTPPacketLossTxTable OBJECT-TYPE
       SYNTAX SEQUENCE OF AcPMRTPPacketLossTxEntry
       MAX-ACCESS not-accessible
       STATUS current
       DESCRIPTION
           "RTP packet loss reported in incoming RTCP data, per trunk."
       ::= {acPMMediaNetworking 8}



     -- ****************************************
     -- acPMRTPPacketLossTx table entry
     -- ****************************************
     acPMRTPPacketLossTxEntry OBJECT-TYPE
       SYNTAX AcPMRTPPacketLossTxEntry
       MAX-ACCESS not-accessible
       STATUS current
       DESCRIPTION
           ""
       INDEX {acPMRTPPacketLossTxTrunkNum,acPMRTPPacketLossTxInterval}
       ::= {acPMRTPPacketLossTxTable 1}



     -- ****************************************
     -- acPMRTPPacketLossTx TABLE
     -- ****************************************
     AcPMRTPPacketLossTxEntry ::= SEQUENCE {
       acPMRTPPacketLossTxTrunkNum                     Unsigned32,
       acPMRTPPacketLossTxInterval                     Unsigned32,
       acPMRTPPacketLossTxVal                          Gauge32,
       acPMRTPPacketLossTxAverage                      Integer32,
       acPMRTPPacketLossTxMax                          Integer32,
       acPMRTPPacketLossTxMin                          Integer32,
       acPMRTPPacketLossTxVolume                       Counter32,
       acPMRTPPacketLossTxTimeBelowLowThreshold        Integer32,
       acPMRTPPacketLossTxTimeBetweenThresholds        Integer32,
       acPMRTPPacketLossTxTimeAboveHighThreshold       Integer32,
       acPMRTPPacketLossTxFullDayAverage               Integer32
     }



     acPMRTPPacketLossTxTrunkNum OBJECT-TYPE
       SYNTAX Unsigned32 (0..83)
       MAX-ACCESS not-accessible
       STATUS current
       DESCRIPTION
           "Trunk number.
0 is the first trunk."
       ::= {acPMRTPPacketLossTxEntry 1}



     acPMRTPPacketLossTxInterval OBJECT-TYPE
       SYNTAX Unsigned32 (0..2)
       MAX-ACCESS not-accessible
       STATUS current
       DESCRIPTION
           "Interval index.
0 - current period (incomplete monitoring - mid period).
1 - Last full period.
2 - One before last."
       ::= {acPMRTPPacketLossTxEntry 2}



     acPMRTPPacketLossTxVal OBJECT-TYPE
       SYNTAX Gauge32
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Value of gauge or counter."
       ::= {acPMRTPPacketLossTxEntry 3}



     acPMRTPPacketLossTxAverage OBJECT-TYPE
       SYNTAX Integer32 (-1..2147483647)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Average value with in the period time."
       ::= {acPMRTPPacketLossTxEntry 4}



     acPMRTPPacketLossTxMax OBJECT-TYPE
       SYNTAX Integer32 (-1..2147483647)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Maximum value with in the period time."
       ::= {acPMRTPPacketLossTxEntry 5}



     acPMRTPPacketLossTxMin OBJECT-TYPE
       SYNTAX Integer32 (-1..2147483647)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Minimum value with in the period time."
       ::= {acPMRTPPacketLossTxEntry 6}



     acPMRTPPacketLossTxVolume OBJECT-TYPE
       SYNTAX Counter32
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Activity volume."
       ::= {acPMRTPPacketLossTxEntry 7}



     acPMRTPPacketLossTxTimeBelowLowThreshold OBJECT-TYPE
       SYNTAX Integer32 (-1..100)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Percent of interval time for which gauge is below what was determined
as the low threshold."
       ::= {acPMRTPPacketLossTxEntry 8}



     acPMRTPPacketLossTxTimeBetweenThresholds OBJECT-TYPE
       SYNTAX Integer32 (-1..100)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Percent of interval time for which gauge is above what was determined
as the high threshold."
       ::= {acPMRTPPacketLossTxEntry 9}



     acPMRTPPacketLossTxTimeAboveHighThreshold OBJECT-TYPE
       SYNTAX Integer32 (-1..100)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Percent of interval time for which gauge is between what were
determined as the low and high thresholds."
       ::= {acPMRTPPacketLossTxEntry 10}



     acPMRTPPacketLossTxFullDayAverage OBJECT-TYPE
       SYNTAX Integer32 (-1..2147483647)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "The average of full 24 hours."
       ::= {acPMRTPPacketLossTxEntry 11}



     -- ****************************************
     -- acPMModuleRTPPacketLossRx table declaration
     -- ****************************************
     acPMModuleRTPPacketLossRxTable OBJECT-TYPE
       SYNTAX SEQUENCE OF AcPMModuleRTPPacketLossRxEntry
       MAX-ACCESS not-accessible
       STATUS current
       DESCRIPTION
           "RTP packet loss reported in incoming RTCP data, per entire module."
       ::= {acPMMediaNetworking 9}



     -- ****************************************
     -- acPMModuleRTPPacketLossRx table entry
     -- ****************************************
     acPMModuleRTPPacketLossRxEntry OBJECT-TYPE
       SYNTAX AcPMModuleRTPPacketLossRxEntry
       MAX-ACCESS not-accessible
       STATUS current
       DESCRIPTION
           ""
       INDEX {acPMModuleRTPPacketLossRxInterval}
       ::= {acPMModuleRTPPacketLossRxTable 1}



     -- ****************************************
     -- acPMModuleRTPPacketLossRx TABLE
     -- ****************************************
     AcPMModuleRTPPacketLossRxEntry ::= SEQUENCE {
       acPMModuleRTPPacketLossRxInterval               Unsigned32,
       acPMModuleRTPPacketLossRxAverage                Integer32,
       acPMModuleRTPPacketLossRxMax                    Integer32,
       acPMModuleRTPPacketLossRxMin                    Integer32,
       acPMModuleRTPPacketLossRxVolume                 Counter32,
       acPMModuleRTPPacketLossRxTimeBelowLowThreshold  Integer32,
       acPMModuleRTPPacketLossRxTimeBetweenThresholds  Integer32,
       acPMModuleRTPPacketLossRxTimeAboveHighThreshold Integer32,
       acPMModuleRTPPacketLossRxFullDayAverage         Integer32,
       acPMModuleRTPPacketLossRxTotal                  Integer32
     }



     acPMModuleRTPPacketLossRxInterval OBJECT-TYPE
       SYNTAX Unsigned32 (0..2)
       MAX-ACCESS not-accessible
       STATUS current
       DESCRIPTION
           "Interval index.
0 - current period (incomplete monitoring - mid period).
1 - Last full period.
2 - One before last."
       ::= {acPMModuleRTPPacketLossRxEntry 1}



     acPMModuleRTPPacketLossRxAverage OBJECT-TYPE
       SYNTAX Integer32 (-1..2147483647)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Average value with in the period time."
       ::= {acPMModuleRTPPacketLossRxEntry 2}



     acPMModuleRTPPacketLossRxMax OBJECT-TYPE
       SYNTAX Integer32 (-1..2147483647)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Maximum value with in the period time."
       ::= {acPMModuleRTPPacketLossRxEntry 3}



     acPMModuleRTPPacketLossRxMin OBJECT-TYPE
       SYNTAX Integer32 (-1..2147483647)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Minimum value with in the period time."
       ::= {acPMModuleRTPPacketLossRxEntry 4}



     acPMModuleRTPPacketLossRxVolume OBJECT-TYPE
       SYNTAX Counter32
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Activity volume."
       ::= {acPMModuleRTPPacketLossRxEntry 5}



     acPMModuleRTPPacketLossRxTimeBelowLowThreshold OBJECT-TYPE
       SYNTAX Integer32 (-1..100)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Percent of interval time for which gauge is below what was determined
as the low threshold."
       ::= {acPMModuleRTPPacketLossRxEntry 6}



     acPMModuleRTPPacketLossRxTimeBetweenThresholds OBJECT-TYPE
       SYNTAX Integer32 (-1..100)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Percent of interval time for which gauge is above what was determined
as the high threshold."
       ::= {acPMModuleRTPPacketLossRxEntry 7}



     acPMModuleRTPPacketLossRxTimeAboveHighThreshold OBJECT-TYPE
       SYNTAX Integer32 (-1..100)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Percent of interval time for which gauge is between what were
determined as the low and high thresholds."
       ::= {acPMModuleRTPPacketLossRxEntry 8}



     acPMModuleRTPPacketLossRxFullDayAverage OBJECT-TYPE
       SYNTAX Integer32 (-1..2147483647)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "The average of full 24 hours."
       ::= {acPMModuleRTPPacketLossRxEntry 9}



     acPMModuleRTPPacketLossRxTotal OBJECT-TYPE
       SYNTAX Integer32 (-1..2147483647)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Total since last reset."
       ::= {acPMModuleRTPPacketLossRxEntry 10}



     -- ****************************************
     -- acPMModuleRTPPacketLossTx table declaration
     -- ****************************************
     acPMModuleRTPPacketLossTxTable OBJECT-TYPE
       SYNTAX SEQUENCE OF AcPMModuleRTPPacketLossTxEntry
       MAX-ACCESS not-accessible
       STATUS current
       DESCRIPTION
           "RTP packet loss reported in outging RTCP data, per entire module."
       ::= {acPMMediaNetworking 10}



     -- ****************************************
     -- acPMModuleRTPPacketLossTx table entry
     -- ****************************************
     acPMModuleRTPPacketLossTxEntry OBJECT-TYPE
       SYNTAX AcPMModuleRTPPacketLossTxEntry
       MAX-ACCESS not-accessible
       STATUS current
       DESCRIPTION
           ""
       INDEX {acPMModuleRTPPacketLossTxInterval}
       ::= {acPMModuleRTPPacketLossTxTable 1}



     -- ****************************************
     -- acPMModuleRTPPacketLossTx TABLE
     -- ****************************************
     AcPMModuleRTPPacketLossTxEntry ::= SEQUENCE {
       acPMModuleRTPPacketLossTxInterval               Unsigned32,
       acPMModuleRTPPacketLossTxAverage                Integer32,
       acPMModuleRTPPacketLossTxMax                    Integer32,
       acPMModuleRTPPacketLossTxMin                    Integer32,
       acPMModuleRTPPacketLossTxVolume                 Counter32,
       acPMModuleRTPPacketLossTxTimeBelowLowThreshold  Integer32,
       acPMModuleRTPPacketLossTxTimeBetweenThresholds  Integer32,
       acPMModuleRTPPacketLossTxTimeAboveHighThreshold Integer32,
       acPMModuleRTPPacketLossTxFullDayAverage         Integer32,
       acPMModuleRTPPacketLossTxTotal                  Integer32
     }



     acPMModuleRTPPacketLossTxInterval OBJECT-TYPE
       SYNTAX Unsigned32 (0..2)
       MAX-ACCESS not-accessible
       STATUS current
       DESCRIPTION
           "Interval index.
0 - current period (incomplete monitoring - mid period).
1 - Last full period.
2 - One before last."
       ::= {acPMModuleRTPPacketLossTxEntry 1}



     acPMModuleRTPPacketLossTxAverage OBJECT-TYPE
       SYNTAX Integer32 (-1..2147483647)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Average value with in the period time."
       ::= {acPMModuleRTPPacketLossTxEntry 2}



     acPMModuleRTPPacketLossTxMax OBJECT-TYPE
       SYNTAX Integer32 (-1..2147483647)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Maximum value with in the period time."
       ::= {acPMModuleRTPPacketLossTxEntry 3}



     acPMModuleRTPPacketLossTxMin OBJECT-TYPE
       SYNTAX Integer32 (-1..2147483647)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Minimum value with in the period time."
       ::= {acPMModuleRTPPacketLossTxEntry 4}



     acPMModuleRTPPacketLossTxVolume OBJECT-TYPE
       SYNTAX Counter32
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Activity volume."
       ::= {acPMModuleRTPPacketLossTxEntry 5}



     acPMModuleRTPPacketLossTxTimeBelowLowThreshold OBJECT-TYPE
       SYNTAX Integer32 (-1..100)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Percent of interval time for which gauge is below what was determined
as the low threshold."
       ::= {acPMModuleRTPPacketLossTxEntry 6}



     acPMModuleRTPPacketLossTxTimeBetweenThresholds OBJECT-TYPE
       SYNTAX Integer32 (-1..100)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Percent of interval time for which gauge is above what was determined
as the high threshold."
       ::= {acPMModuleRTPPacketLossTxEntry 7}



     acPMModuleRTPPacketLossTxTimeAboveHighThreshold OBJECT-TYPE
       SYNTAX Integer32 (-1..100)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Percent of interval time for which gauge is between what were
determined as the low and high thresholds."
       ::= {acPMModuleRTPPacketLossTxEntry 8}



     acPMModuleRTPPacketLossTxFullDayAverage OBJECT-TYPE
       SYNTAX Integer32 (-1..2147483647)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "The average of full 24 hours."
       ::= {acPMModuleRTPPacketLossTxEntry 9}



     acPMModuleRTPPacketLossTxTotal OBJECT-TYPE
       SYNTAX Integer32 (-1..2147483647)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Total since last reset."
       ::= {acPMModuleRTPPacketLossTxEntry 10}



     acPMMediaNetworkingAggregated OBJECT IDENTIFIER ::= {acPMMediaNetworking 21}


     -- ****************************************
     -- acPMModulePacketDelay table declaration
     -- ****************************************
     acPMModulePacketDelayTable OBJECT-TYPE
       SYNTAX SEQUENCE OF AcPMModulePacketDelayEntry
       MAX-ACCESS not-accessible
       STATUS current
       DESCRIPTION
           "Packet delay in RTCP data. This counter is collected for the entire TPM module, and includes TDM-IP and IP-IP calls."
       ::= {acPMMediaNetworkingAggregated 1}



     -- ****************************************
     -- acPMModulePacketDelay table entry
     -- ****************************************
     acPMModulePacketDelayEntry OBJECT-TYPE
       SYNTAX AcPMModulePacketDelayEntry
       MAX-ACCESS not-accessible
       STATUS current
       DESCRIPTION
           ""
       INDEX {acPMModulePacketDelayInterval}
       ::= {acPMModulePacketDelayTable 1}



     -- ****************************************
     -- acPMModulePacketDelay TABLE
     -- ****************************************
     AcPMModulePacketDelayEntry ::= SEQUENCE {
       acPMModulePacketDelayInterval                   Unsigned32,
       acPMModulePacketDelayVal                        Gauge32,
       acPMModulePacketDelayAverage                    Integer32,
       acPMModulePacketDelayMax                        Integer32,
       acPMModulePacketDelayMin                        Integer32,
       acPMModulePacketDelayTimeBelowLowThreshold      Integer32,
       acPMModulePacketDelayTimeBetweenThresholds      Integer32,
       acPMModulePacketDelayTimeAboveHighThreshold     Integer32,
       acPMModulePacketDelayFullDayAverage             Integer32,
       acPMModulePacketDelayVolume                     Counter32
     }



     acPMModulePacketDelayInterval OBJECT-TYPE
       SYNTAX Unsigned32 (0..2)
       MAX-ACCESS not-accessible
       STATUS current
       DESCRIPTION
           "Interval index.
0 - current period (incomplete monitoring - mid period).
1 - Last full period.
2 - One before last."
       ::= {acPMModulePacketDelayEntry 1}



     acPMModulePacketDelayVal OBJECT-TYPE
       SYNTAX Gauge32
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Value of gauge or counter."
       ::= {acPMModulePacketDelayEntry 2}



     acPMModulePacketDelayAverage OBJECT-TYPE
       SYNTAX Integer32 (-1..2147483647)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Average value with in the period time."
       ::= {acPMModulePacketDelayEntry 3}



     acPMModulePacketDelayMax OBJECT-TYPE
       SYNTAX Integer32 (-1..2147483647)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Maximum value with in the period time."
       ::= {acPMModulePacketDelayEntry 4}



     acPMModulePacketDelayMin OBJECT-TYPE
       SYNTAX Integer32 (-1..2147483647)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Minimum value with in the period time."
       ::= {acPMModulePacketDelayEntry 5}



     acPMModulePacketDelayTimeBelowLowThreshold OBJECT-TYPE
       SYNTAX Integer32 (-1..100)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Percent of interval time for which gauge is below what was determined
as the low threshold."
       ::= {acPMModulePacketDelayEntry 6}



     acPMModulePacketDelayTimeBetweenThresholds OBJECT-TYPE
       SYNTAX Integer32 (-1..100)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Percent of interval time for which gauge is above what was determined
as the high threshold."
       ::= {acPMModulePacketDelayEntry 7}



     acPMModulePacketDelayTimeAboveHighThreshold OBJECT-TYPE
       SYNTAX Integer32 (-1..100)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Percent of interval time for which gauge is between what were
determined as the low and high thresholds."
       ::= {acPMModulePacketDelayEntry 8}



     acPMModulePacketDelayFullDayAverage OBJECT-TYPE
       SYNTAX Integer32 (-1..2147483647)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "The average of full 24 hours."
       ::= {acPMModulePacketDelayEntry 9}



     acPMModulePacketDelayVolume OBJECT-TYPE
       SYNTAX Counter32
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Activity volume."
       ::= {acPMModulePacketDelayEntry 10}



     -- ****************************************
     -- acPMModulePacketJitter table declaration
     -- ****************************************
     acPMModulePacketJitterTable OBJECT-TYPE
       SYNTAX SEQUENCE OF AcPMModulePacketJitterEntry
       MAX-ACCESS not-accessible
       STATUS current
       DESCRIPTION
           "Packet jitter in RTCP data. This counter is collected for the entire TPM module, and includes TDM-IP and IP-IP calls."
       ::= {acPMMediaNetworkingAggregated 2}



     -- ****************************************
     -- acPMModulePacketJitter table entry
     -- ****************************************
     acPMModulePacketJitterEntry OBJECT-TYPE
       SYNTAX AcPMModulePacketJitterEntry
       MAX-ACCESS not-accessible
       STATUS current
       DESCRIPTION
           ""
       INDEX {acPMModulePacketJitterInterval}
       ::= {acPMModulePacketJitterTable 1}



     -- ****************************************
     -- acPMModulePacketJitter TABLE
     -- ****************************************
     AcPMModulePacketJitterEntry ::= SEQUENCE {
       acPMModulePacketJitterInterval                  Unsigned32,
       acPMModulePacketJitterVal                       Gauge32,
       acPMModulePacketJitterAverage                   Integer32,
       acPMModulePacketJitterMax                       Integer32,
       acPMModulePacketJitterMin                       Integer32,
       acPMModulePacketJitterTimeBelowLowThreshold     Integer32,
       acPMModulePacketJitterTimeBetweenThresholds     Integer32,
       acPMModulePacketJitterTimeAboveHighThreshold    Integer32,
       acPMModulePacketJitterFullDayAverage            Integer32,
       acPMModulePacketJitterVolume                    Counter32
     }



     acPMModulePacketJitterInterval OBJECT-TYPE
       SYNTAX Unsigned32 (0..2)
       MAX-ACCESS not-accessible
       STATUS current
       DESCRIPTION
           "Interval index.
0 - current period (incomplete monitoring - mid period).
1 - Last full period.
2 - One before last."
       ::= {acPMModulePacketJitterEntry 1}



     acPMModulePacketJitterVal OBJECT-TYPE
       SYNTAX Gauge32
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Value of gauge or counter."
       ::= {acPMModulePacketJitterEntry 2}



     acPMModulePacketJitterAverage OBJECT-TYPE
       SYNTAX Integer32 (-1..2147483647)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Average value with in the period time."
       ::= {acPMModulePacketJitterEntry 3}



     acPMModulePacketJitterMax OBJECT-TYPE
       SYNTAX Integer32 (-1..2147483647)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Maximum value with in the period time."
       ::= {acPMModulePacketJitterEntry 4}



     acPMModulePacketJitterMin OBJECT-TYPE
       SYNTAX Integer32 (-1..2147483647)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Minimum value with in the period time."
       ::= {acPMModulePacketJitterEntry 5}



     acPMModulePacketJitterTimeBelowLowThreshold OBJECT-TYPE
       SYNTAX Integer32 (-1..100)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Percent of interval time for which gauge is below what was determined
as the low threshold."
       ::= {acPMModulePacketJitterEntry 6}



     acPMModulePacketJitterTimeBetweenThresholds OBJECT-TYPE
       SYNTAX Integer32 (-1..100)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Percent of interval time for which gauge is above what was determined
as the high threshold."
       ::= {acPMModulePacketJitterEntry 7}



     acPMModulePacketJitterTimeAboveHighThreshold OBJECT-TYPE
       SYNTAX Integer32 (-1..100)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Percent of interval time for which gauge is between what were
determined as the low and high thresholds."
       ::= {acPMModulePacketJitterEntry 8}



     acPMModulePacketJitterFullDayAverage OBJECT-TYPE
       SYNTAX Integer32 (-1..2147483647)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "The average of full 24 hours."
       ::= {acPMModulePacketJitterEntry 9}



     acPMModulePacketJitterVolume OBJECT-TYPE
       SYNTAX Counter32
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Activity volume."
       ::= {acPMModulePacketJitterEntry 10}



     -- ****************************************
     -- acPMModuleRTPBytesTx table declaration
     -- ****************************************
     acPMModuleRTPBytesTxTable OBJECT-TYPE
       SYNTAX SEQUENCE OF AcPMModuleRTPBytesTxEntry
       MAX-ACCESS not-accessible
       STATUS current
       DESCRIPTION
           "RTP bytes sent in RTCP data, per entire module."
       ::= {acPMMediaNetworkingAggregated 3}



     -- ****************************************
     -- acPMModuleRTPBytesTx table entry
     -- ****************************************
     acPMModuleRTPBytesTxEntry OBJECT-TYPE
       SYNTAX AcPMModuleRTPBytesTxEntry
       MAX-ACCESS not-accessible
       STATUS current
       DESCRIPTION
           ""
       INDEX {acPMModuleRTPBytesTxInterval}
       ::= {acPMModuleRTPBytesTxTable 1}



     -- ****************************************
     -- acPMModuleRTPBytesTx TABLE
     -- ****************************************
     AcPMModuleRTPBytesTxEntry ::= SEQUENCE {
       acPMModuleRTPBytesTxInterval                    Unsigned32,
       acPMModuleRTPBytesTxAverage                     Integer32,
       acPMModuleRTPBytesTxMax                         Integer32,
       acPMModuleRTPBytesTxMin                         Integer32,
       acPMModuleRTPBytesTxTimeBelowLowThreshold       Integer32,
       acPMModuleRTPBytesTxTimeBetweenThresholds       Integer32,
       acPMModuleRTPBytesTxTimeAboveHighThreshold      Integer32,
       acPMModuleRTPBytesTxFullDayAverage              Integer32,
       acPMModuleRTPBytesTxVolume                      Counter32
     }



     acPMModuleRTPBytesTxInterval OBJECT-TYPE
       SYNTAX Unsigned32 (0..2)
       MAX-ACCESS not-accessible
       STATUS current
       DESCRIPTION
           "Interval index.
0 - current period (incomplete monitoring - mid period).
1 - Last full period.
2 - One before last."
       ::= {acPMModuleRTPBytesTxEntry 1}



     acPMModuleRTPBytesTxAverage OBJECT-TYPE
       SYNTAX Integer32 (-1..2147483647)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Average value with in the period time."
       ::= {acPMModuleRTPBytesTxEntry 2}



     acPMModuleRTPBytesTxMax OBJECT-TYPE
       SYNTAX Integer32 (-1..2147483647)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Maximum value with in the period time."
       ::= {acPMModuleRTPBytesTxEntry 3}



     acPMModuleRTPBytesTxMin OBJECT-TYPE
       SYNTAX Integer32 (-1..2147483647)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Minimum value with in the period time."
       ::= {acPMModuleRTPBytesTxEntry 4}



     acPMModuleRTPBytesTxTimeBelowLowThreshold OBJECT-TYPE
       SYNTAX Integer32 (-1..100)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Percent of interval time for which gauge is below what was determined
as the low threshold."
       ::= {acPMModuleRTPBytesTxEntry 5}



     acPMModuleRTPBytesTxTimeBetweenThresholds OBJECT-TYPE
       SYNTAX Integer32 (-1..100)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Percent of interval time for which gauge is above what was determined
as the high threshold."
       ::= {acPMModuleRTPBytesTxEntry 6}



     acPMModuleRTPBytesTxTimeAboveHighThreshold OBJECT-TYPE
       SYNTAX Integer32 (-1..100)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Percent of interval time for which gauge is between what were
determined as the low and high thresholds."
       ::= {acPMModuleRTPBytesTxEntry 7}



     acPMModuleRTPBytesTxFullDayAverage OBJECT-TYPE
       SYNTAX Integer32 (-1..2147483647)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "The average of full 24 hours."
       ::= {acPMModuleRTPBytesTxEntry 8}



     acPMModuleRTPBytesTxVolume OBJECT-TYPE
       SYNTAX Counter32
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Activity volume."
       ::= {acPMModuleRTPBytesTxEntry 9}



     -- ****************************************
     -- acPMModuleRTPBytesRx table declaration
     -- ****************************************
     acPMModuleRTPBytesRxTable OBJECT-TYPE
       SYNTAX SEQUENCE OF AcPMModuleRTPBytesRxEntry
       MAX-ACCESS not-accessible
       STATUS current
       DESCRIPTION
           "RTP bytes received in RTCP data, per entire module."
       ::= {acPMMediaNetworkingAggregated 4}



     -- ****************************************
     -- acPMModuleRTPBytesRx table entry
     -- ****************************************
     acPMModuleRTPBytesRxEntry OBJECT-TYPE
       SYNTAX AcPMModuleRTPBytesRxEntry
       MAX-ACCESS not-accessible
       STATUS current
       DESCRIPTION
           ""
       INDEX {acPMModuleRTPBytesRxInterval}
       ::= {acPMModuleRTPBytesRxTable 1}



     -- ****************************************
     -- acPMModuleRTPBytesRx TABLE
     -- ****************************************
     AcPMModuleRTPBytesRxEntry ::= SEQUENCE {
       acPMModuleRTPBytesRxInterval                    Unsigned32,
       acPMModuleRTPBytesRxAverage                     Integer32,
       acPMModuleRTPBytesRxMax                         Integer32,
       acPMModuleRTPBytesRxMin                         Integer32,
       acPMModuleRTPBytesRxTimeBelowLowThreshold       Integer32,
       acPMModuleRTPBytesRxTimeBetweenThresholds       Integer32,
       acPMModuleRTPBytesRxTimeAboveHighThreshold      Integer32,
       acPMModuleRTPBytesRxFullDayAverage              Integer32,
       acPMModuleRTPBytesRxVolume                      Counter32
     }



     acPMModuleRTPBytesRxInterval OBJECT-TYPE
       SYNTAX Unsigned32 (0..2)
       MAX-ACCESS not-accessible
       STATUS current
       DESCRIPTION
           "Interval index.
0 - current period (incomplete monitoring - mid period).
1 - Last full period.
2 - One before last."
       ::= {acPMModuleRTPBytesRxEntry 1}



     acPMModuleRTPBytesRxAverage OBJECT-TYPE
       SYNTAX Integer32 (-1..2147483647)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Average value with in the period time."
       ::= {acPMModuleRTPBytesRxEntry 2}



     acPMModuleRTPBytesRxMax OBJECT-TYPE
       SYNTAX Integer32 (-1..2147483647)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Maximum value with in the period time."
       ::= {acPMModuleRTPBytesRxEntry 3}



     acPMModuleRTPBytesRxMin OBJECT-TYPE
       SYNTAX Integer32 (-1..2147483647)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Minimum value with in the period time."
       ::= {acPMModuleRTPBytesRxEntry 4}



     acPMModuleRTPBytesRxTimeBelowLowThreshold OBJECT-TYPE
       SYNTAX Integer32 (-1..100)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Percent of interval time for which gauge is below what was determined
as the low threshold."
       ::= {acPMModuleRTPBytesRxEntry 5}



     acPMModuleRTPBytesRxTimeBetweenThresholds OBJECT-TYPE
       SYNTAX Integer32 (-1..100)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Percent of interval time for which gauge is above what was determined
as the high threshold."
       ::= {acPMModuleRTPBytesRxEntry 6}



     acPMModuleRTPBytesRxTimeAboveHighThreshold OBJECT-TYPE
       SYNTAX Integer32 (-1..100)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Percent of interval time for which gauge is between what were
determined as the low and high thresholds."
       ::= {acPMModuleRTPBytesRxEntry 7}



     acPMModuleRTPBytesRxFullDayAverage OBJECT-TYPE
       SYNTAX Integer32 (-1..2147483647)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "The average of full 24 hours."
       ::= {acPMModuleRTPBytesRxEntry 8}



     acPMModuleRTPBytesRxVolume OBJECT-TYPE
       SYNTAX Counter32
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Activity volume."
       ::= {acPMModuleRTPBytesRxEntry 9}



     -- ****************************************
     -- acPMModuleRTPPacketsTx table declaration
     -- ****************************************
     acPMModuleRTPPacketsTxTable OBJECT-TYPE
       SYNTAX SEQUENCE OF AcPMModuleRTPPacketsTxEntry
       MAX-ACCESS not-accessible
       STATUS current
       DESCRIPTION
           "RTP packets sent in RTCP data, per entire module."
       ::= {acPMMediaNetworkingAggregated 5}



     -- ****************************************
     -- acPMModuleRTPPacketsTx table entry
     -- ****************************************
     acPMModuleRTPPacketsTxEntry OBJECT-TYPE
       SYNTAX AcPMModuleRTPPacketsTxEntry
       MAX-ACCESS not-accessible
       STATUS current
       DESCRIPTION
           ""
       INDEX {acPMModuleRTPPacketsTxInterval}
       ::= {acPMModuleRTPPacketsTxTable 1}



     -- ****************************************
     -- acPMModuleRTPPacketsTx TABLE
     -- ****************************************
     AcPMModuleRTPPacketsTxEntry ::= SEQUENCE {
       acPMModuleRTPPacketsTxInterval                  Unsigned32,
       acPMModuleRTPPacketsTxAverage                   Integer32,
       acPMModuleRTPPacketsTxMax                       Integer32,
       acPMModuleRTPPacketsTxMin                       Integer32,
       acPMModuleRTPPacketsTxTimeBelowLowThreshold     Integer32,
       acPMModuleRTPPacketsTxTimeBetweenThresholds     Integer32,
       acPMModuleRTPPacketsTxTimeAboveHighThreshold    Integer32,
       acPMModuleRTPPacketsTxFullDayAverage            Integer32,
       acPMModuleRTPPacketsTxTotal                     Integer32,
       acPMModuleRTPPacketsTxVolume                    Counter32
     }



     acPMModuleRTPPacketsTxInterval OBJECT-TYPE
       SYNTAX Unsigned32 (0..2)
       MAX-ACCESS not-accessible
       STATUS current
       DESCRIPTION
           "Interval index.
0 - current period (incomplete monitoring - mid period).
1 - Last full period.
2 - One before last."
       ::= {acPMModuleRTPPacketsTxEntry 1}



     acPMModuleRTPPacketsTxAverage OBJECT-TYPE
       SYNTAX Integer32 (-1..2147483647)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Average value with in the period time."
       ::= {acPMModuleRTPPacketsTxEntry 2}



     acPMModuleRTPPacketsTxMax OBJECT-TYPE
       SYNTAX Integer32 (-1..2147483647)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Maximum value with in the period time."
       ::= {acPMModuleRTPPacketsTxEntry 3}



     acPMModuleRTPPacketsTxMin OBJECT-TYPE
       SYNTAX Integer32 (-1..2147483647)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Minimum value with in the period time."
       ::= {acPMModuleRTPPacketsTxEntry 4}



     acPMModuleRTPPacketsTxTimeBelowLowThreshold OBJECT-TYPE
       SYNTAX Integer32 (-1..100)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Percent of interval time for which gauge is below what was determined
as the low threshold."
       ::= {acPMModuleRTPPacketsTxEntry 5}



     acPMModuleRTPPacketsTxTimeBetweenThresholds OBJECT-TYPE
       SYNTAX Integer32 (-1..100)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Percent of interval time for which gauge is above what was determined
as the high threshold."
       ::= {acPMModuleRTPPacketsTxEntry 6}



     acPMModuleRTPPacketsTxTimeAboveHighThreshold OBJECT-TYPE
       SYNTAX Integer32 (-1..100)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Percent of interval time for which gauge is between what were
determined as the low and high thresholds."
       ::= {acPMModuleRTPPacketsTxEntry 7}



     acPMModuleRTPPacketsTxFullDayAverage OBJECT-TYPE
       SYNTAX Integer32 (-1..2147483647)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "The average of full 24 hours."
       ::= {acPMModuleRTPPacketsTxEntry 8}



     acPMModuleRTPPacketsTxTotal OBJECT-TYPE
       SYNTAX Integer32 (-1..2147483647)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Total since last reset."
       ::= {acPMModuleRTPPacketsTxEntry 9}



     acPMModuleRTPPacketsTxVolume OBJECT-TYPE
       SYNTAX Counter32
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Activity volume."
       ::= {acPMModuleRTPPacketsTxEntry 10}



     -- ****************************************
     -- acPMModuleRTPPacketsRx table declaration
     -- ****************************************
     acPMModuleRTPPacketsRxTable OBJECT-TYPE
       SYNTAX SEQUENCE OF AcPMModuleRTPPacketsRxEntry
       MAX-ACCESS not-accessible
       STATUS current
       DESCRIPTION
           "RTP packets received in RTCP data, per entire module."
       ::= {acPMMediaNetworkingAggregated 6}



     -- ****************************************
     -- acPMModuleRTPPacketsRx table entry
     -- ****************************************
     acPMModuleRTPPacketsRxEntry OBJECT-TYPE
       SYNTAX AcPMModuleRTPPacketsRxEntry
       MAX-ACCESS not-accessible
       STATUS current
       DESCRIPTION
           ""
       INDEX {acPMModuleRTPPacketsRxInterval}
       ::= {acPMModuleRTPPacketsRxTable 1}



     -- ****************************************
     -- acPMModuleRTPPacketsRx TABLE
     -- ****************************************
     AcPMModuleRTPPacketsRxEntry ::= SEQUENCE {
       acPMModuleRTPPacketsRxInterval                  Unsigned32,
       acPMModuleRTPPacketsRxAverage                   Integer32,
       acPMModuleRTPPacketsRxMax                       Integer32,
       acPMModuleRTPPacketsRxMin                       Integer32,
       acPMModuleRTPPacketsRxTimeBelowLowThreshold     Integer32,
       acPMModuleRTPPacketsRxTimeBetweenThresholds     Integer32,
       acPMModuleRTPPacketsRxTimeAboveHighThreshold    Integer32,
       acPMModuleRTPPacketsRxFullDayAverage            Integer32,
       acPMModuleRTPPacketsRxTotal                     Integer32,
       acPMModuleRTPPacketsRxVolume                    Counter32
     }



     acPMModuleRTPPacketsRxInterval OBJECT-TYPE
       SYNTAX Unsigned32 (0..2)
       MAX-ACCESS not-accessible
       STATUS current
       DESCRIPTION
           "Interval index.
0 - current period (incomplete monitoring - mid period).
1 - Last full period.
2 - One before last."
       ::= {acPMModuleRTPPacketsRxEntry 1}



     acPMModuleRTPPacketsRxAverage OBJECT-TYPE
       SYNTAX Integer32 (-1..2147483647)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Average value with in the period time."
       ::= {acPMModuleRTPPacketsRxEntry 2}



     acPMModuleRTPPacketsRxMax OBJECT-TYPE
       SYNTAX Integer32 (-1..2147483647)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Maximum value with in the period time."
       ::= {acPMModuleRTPPacketsRxEntry 3}



     acPMModuleRTPPacketsRxMin OBJECT-TYPE
       SYNTAX Integer32 (-1..2147483647)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Minimum value with in the period time."
       ::= {acPMModuleRTPPacketsRxEntry 4}



     acPMModuleRTPPacketsRxTimeBelowLowThreshold OBJECT-TYPE
       SYNTAX Integer32 (-1..100)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Percent of interval time for which gauge is below what was determined
as the low threshold."
       ::= {acPMModuleRTPPacketsRxEntry 5}



     acPMModuleRTPPacketsRxTimeBetweenThresholds OBJECT-TYPE
       SYNTAX Integer32 (-1..100)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Percent of interval time for which gauge is above what was determined
as the high threshold."
       ::= {acPMModuleRTPPacketsRxEntry 6}



     acPMModuleRTPPacketsRxTimeAboveHighThreshold OBJECT-TYPE
       SYNTAX Integer32 (-1..100)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Percent of interval time for which gauge is between what were
determined as the low and high thresholds."
       ::= {acPMModuleRTPPacketsRxEntry 7}



     acPMModuleRTPPacketsRxFullDayAverage OBJECT-TYPE
       SYNTAX Integer32 (-1..2147483647)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "The average of full 24 hours."
       ::= {acPMModuleRTPPacketsRxEntry 8}



     acPMModuleRTPPacketsRxTotal OBJECT-TYPE
       SYNTAX Integer32 (-1..2147483647)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Total since last reset."
       ::= {acPMModuleRTPPacketsRxEntry 9}



     acPMModuleRTPPacketsRxVolume OBJECT-TYPE
       SYNTAX Counter32
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Activity volume."
       ::= {acPMModuleRTPPacketsRxEntry 10}



     acPMChannelUtilization OBJECT IDENTIFIER ::= {acPMMediaData 41}


     -- ****************************************
     -- acPMFaxChannels table declaration
     -- ****************************************
     acPMFaxChannelsTable OBJECT-TYPE
       SYNTAX SEQUENCE OF AcPMFaxChannelsEntry
       MAX-ACCESS not-accessible
       STATUS current
       DESCRIPTION
           "Total number of active fax channels."
       ::= {acPMChannelUtilization 1}



     -- ****************************************
     -- acPMFaxChannels table entry
     -- ****************************************
     acPMFaxChannelsEntry OBJECT-TYPE
       SYNTAX AcPMFaxChannelsEntry
       MAX-ACCESS not-accessible
       STATUS current
       DESCRIPTION
           ""
       INDEX {acPMFaxChannelsInterval}
       ::= {acPMFaxChannelsTable 1}



     -- ****************************************
     -- acPMFaxChannels TABLE
     -- ****************************************
     AcPMFaxChannelsEntry ::= SEQUENCE {
       acPMFaxChannelsInterval                         Unsigned32,
       acPMFaxChannelsVal                              Gauge32,
       acPMFaxChannelsAverage                          Integer32,
       acPMFaxChannelsMax                              Integer32,
       acPMFaxChannelsMin                              Integer32,
       acPMFaxChannelsTimeBelowLowThreshold            Integer32,
       acPMFaxChannelsTimeBetweenThresholds            Integer32,
       acPMFaxChannelsTimeAboveHighThreshold           Integer32,
       acPMFaxChannelsFullDayAverage                   Integer32,
       acPMFaxChannelsVolume                           Counter32
     }



     acPMFaxChannelsInterval OBJECT-TYPE
       SYNTAX Unsigned32 (0..2)
       MAX-ACCESS not-accessible
       STATUS current
       DESCRIPTION
           "Interval index.
0 - current period (incomplete monitoring - mid period).
1 - Last full period.
2 - One before last."
       ::= {acPMFaxChannelsEntry 1}



     acPMFaxChannelsVal OBJECT-TYPE
       SYNTAX Gauge32
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Value of gauge or counter."
       ::= {acPMFaxChannelsEntry 2}



     acPMFaxChannelsAverage OBJECT-TYPE
       SYNTAX Integer32 (-1..2147483647)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Average value with in the period time."
       ::= {acPMFaxChannelsEntry 3}



     acPMFaxChannelsMax OBJECT-TYPE
       SYNTAX Integer32 (-1..2147483647)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Maximum value with in the period time."
       ::= {acPMFaxChannelsEntry 4}



     acPMFaxChannelsMin OBJECT-TYPE
       SYNTAX Integer32 (-1..2147483647)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Minimum value with in the period time."
       ::= {acPMFaxChannelsEntry 5}



     acPMFaxChannelsTimeBelowLowThreshold OBJECT-TYPE
       SYNTAX Integer32 (-1..100)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Percent of interval time for which gauge is below what was determined
as the low threshold."
       ::= {acPMFaxChannelsEntry 6}



     acPMFaxChannelsTimeBetweenThresholds OBJECT-TYPE
       SYNTAX Integer32 (-1..100)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Percent of interval time for which gauge is above what was determined
as the high threshold."
       ::= {acPMFaxChannelsEntry 7}



     acPMFaxChannelsTimeAboveHighThreshold OBJECT-TYPE
       SYNTAX Integer32 (-1..100)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Percent of interval time for which gauge is between what were
determined as the low and high thresholds."
       ::= {acPMFaxChannelsEntry 8}



     acPMFaxChannelsFullDayAverage OBJECT-TYPE
       SYNTAX Integer32 (-1..2147483647)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "The average of full 24 hours."
       ::= {acPMFaxChannelsEntry 9}



     acPMFaxChannelsVolume OBJECT-TYPE
       SYNTAX Counter32
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Activity volume."
       ::= {acPMFaxChannelsEntry 10}



     -- ****************************************
     -- acPMModemChannels table declaration
     -- ****************************************
     acPMModemChannelsTable OBJECT-TYPE
       SYNTAX SEQUENCE OF AcPMModemChannelsEntry
       MAX-ACCESS not-accessible
       STATUS current
       DESCRIPTION
           "Total number of active modem channels."
       ::= {acPMChannelUtilization 2}



     -- ****************************************
     -- acPMModemChannels table entry
     -- ****************************************
     acPMModemChannelsEntry OBJECT-TYPE
       SYNTAX AcPMModemChannelsEntry
       MAX-ACCESS not-accessible
       STATUS current
       DESCRIPTION
           ""
       INDEX {acPMModemChannelsInterval}
       ::= {acPMModemChannelsTable 1}



     -- ****************************************
     -- acPMModemChannels TABLE
     -- ****************************************
     AcPMModemChannelsEntry ::= SEQUENCE {
       acPMModemChannelsInterval                       Unsigned32,
       acPMModemChannelsVal                            Gauge32,
       acPMModemChannelsAverage                        Integer32,
       acPMModemChannelsMax                            Integer32,
       acPMModemChannelsMin                            Integer32,
       acPMModemChannelsTimeBelowLowThreshold          Integer32,
       acPMModemChannelsTimeBetweenThresholds          Integer32,
       acPMModemChannelsTimeAboveHighThreshold         Integer32,
       acPMModemChannelsFullDayAverage                 Integer32
     }



     acPMModemChannelsInterval OBJECT-TYPE
       SYNTAX Unsigned32 (0..2)
       MAX-ACCESS not-accessible
       STATUS current
       DESCRIPTION
           "Interval index.
0 - current period (incomplete monitoring - mid period).
1 - Last full period.
2 - One before last."
       ::= {acPMModemChannelsEntry 1}



     acPMModemChannelsVal OBJECT-TYPE
       SYNTAX Gauge32
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Value of gauge or counter."
       ::= {acPMModemChannelsEntry 2}



     acPMModemChannelsAverage OBJECT-TYPE
       SYNTAX Integer32 (-1..2147483647)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Average value within the period time."
       ::= {acPMModemChannelsEntry 3}



     acPMModemChannelsMax OBJECT-TYPE
       SYNTAX Integer32 (-1..2147483647)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Maximum value within the period time."
       ::= {acPMModemChannelsEntry 4}



     acPMModemChannelsMin OBJECT-TYPE
       SYNTAX Integer32 (-1..2147483647)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Minimum value within the period time."
       ::= {acPMModemChannelsEntry 5}



     acPMModemChannelsTimeBelowLowThreshold OBJECT-TYPE
       SYNTAX Integer32 (-1..100)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Percent of interval time for which gauge is below what was determined
as the low threshold."
       ::= {acPMModemChannelsEntry 6}



     acPMModemChannelsTimeBetweenThresholds OBJECT-TYPE
       SYNTAX Integer32 (-1..100)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Percent of interval time for which gauge is above what was determined
as the high threshold."
       ::= {acPMModemChannelsEntry 7}



     acPMModemChannelsTimeAboveHighThreshold OBJECT-TYPE
       SYNTAX Integer32 (-1..100)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Percent of interval time for which gauge is between what were
determined as the low and high thresholds."
       ::= {acPMModemChannelsEntry 8}



     acPMModemChannelsFullDayAverage OBJECT-TYPE
       SYNTAX Integer32 (-1..2147483647)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "The average of full 24 hours."
       ::= {acPMModemChannelsEntry 9}



     -- ****************************************
     -- acPMTdm2IpChannels table declaration
     -- ****************************************
     acPMTdm2IpChannelsTable OBJECT-TYPE
       SYNTAX SEQUENCE OF AcPMTdm2IpChannelsEntry
       MAX-ACCESS not-accessible
       STATUS current
       DESCRIPTION
           "Total number of active TDM-to-IP channels."
       ::= {acPMChannelUtilization 3}



     -- ****************************************
     -- acPMTdm2IpChannels table entry
     -- ****************************************
     acPMTdm2IpChannelsEntry OBJECT-TYPE
       SYNTAX AcPMTdm2IpChannelsEntry
       MAX-ACCESS not-accessible
       STATUS current
       DESCRIPTION
           ""
       INDEX {acPMTdm2IpChannelsInterval}
       ::= {acPMTdm2IpChannelsTable 1}



     -- ****************************************
     -- acPMTdm2IpChannels TABLE
     -- ****************************************
     AcPMTdm2IpChannelsEntry ::= SEQUENCE {
       acPMTdm2IpChannelsInterval                      Unsigned32,
       acPMTdm2IpChannelsVal                           Gauge32,
       acPMTdm2IpChannelsAverage                       Integer32,
       acPMTdm2IpChannelsMax                           Integer32,
       acPMTdm2IpChannelsMin                           Integer32,
       acPMTdm2IpChannelsVolume                        Counter32,
       acPMTdm2IpChannelsTimeBelowLowThreshold         Integer32,
       acPMTdm2IpChannelsTimeBetweenThresholds         Integer32,
       acPMTdm2IpChannelsTimeAboveHighThreshold        Integer32,
       acPMTdm2IpChannelsFullDayAverage                Integer32
     }



     acPMTdm2IpChannelsInterval OBJECT-TYPE
       SYNTAX Unsigned32 (0..2)
       MAX-ACCESS not-accessible
       STATUS current
       DESCRIPTION
           "Interval index.
0 - current period (incomplete monitoring - mid period).
1 - Last full period.
2 - One before last."
       ::= {acPMTdm2IpChannelsEntry 1}



     acPMTdm2IpChannelsVal OBJECT-TYPE
       SYNTAX Gauge32
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Value of gauge or counter."
       ::= {acPMTdm2IpChannelsEntry 2}



     acPMTdm2IpChannelsAverage OBJECT-TYPE
       SYNTAX Integer32 (-1..2147483647)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Average value within the period time."
       ::= {acPMTdm2IpChannelsEntry 3}



     acPMTdm2IpChannelsMax OBJECT-TYPE
       SYNTAX Integer32 (-1..2147483647)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Maximum value within the period time."
       ::= {acPMTdm2IpChannelsEntry 4}



     acPMTdm2IpChannelsMin OBJECT-TYPE
       SYNTAX Integer32 (-1..2147483647)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Minimum value within the period time."
       ::= {acPMTdm2IpChannelsEntry 5}



     acPMTdm2IpChannelsVolume OBJECT-TYPE
       SYNTAX Counter32
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Activity volume."
       ::= {acPMTdm2IpChannelsEntry 6}



     acPMTdm2IpChannelsTimeBelowLowThreshold OBJECT-TYPE
       SYNTAX Integer32 (-1..100)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Percent of interval time for which gauge is below what was determined
as the low threshold."
       ::= {acPMTdm2IpChannelsEntry 7}



     acPMTdm2IpChannelsTimeBetweenThresholds OBJECT-TYPE
       SYNTAX Integer32 (-1..100)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Percent of interval time for which gauge is above what was determined
as the high threshold."
       ::= {acPMTdm2IpChannelsEntry 8}



     acPMTdm2IpChannelsTimeAboveHighThreshold OBJECT-TYPE
       SYNTAX Integer32 (-1..100)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Percent of interval time for which gauge is between what were
determined as the low and high thresholds."
       ::= {acPMTdm2IpChannelsEntry 9}



     acPMTdm2IpChannelsFullDayAverage OBJECT-TYPE
       SYNTAX Integer32 (-1..2147483647)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "The average of full 24 hours."
       ::= {acPMTdm2IpChannelsEntry 10}



     -- ****************************************
     -- acPMRTPStreams table declaration
     -- ****************************************
     acPMRTPStreamsTable OBJECT-TYPE
       SYNTAX SEQUENCE OF AcPMRTPStreamsEntry
       MAX-ACCESS not-accessible
       STATUS current
       DESCRIPTION
           "Total number of active RTP streams."
       ::= {acPMChannelUtilization 4}



     -- ****************************************
     -- acPMRTPStreams table entry
     -- ****************************************
     acPMRTPStreamsEntry OBJECT-TYPE
       SYNTAX AcPMRTPStreamsEntry
       MAX-ACCESS not-accessible
       STATUS current
       DESCRIPTION
           ""
       INDEX {acPMRTPStreamsInterval}
       ::= {acPMRTPStreamsTable 1}



     -- ****************************************
     -- acPMRTPStreams TABLE
     -- ****************************************
     AcPMRTPStreamsEntry ::= SEQUENCE {
       acPMRTPStreamsInterval                          Unsigned32,
       acPMRTPStreamsVal                               Gauge32,
       acPMRTPStreamsAverage                           Integer32,
       acPMRTPStreamsMax                               Integer32,
       acPMRTPStreamsMin                               Integer32,
       acPMRTPStreamsVolume                            Counter32,
       acPMRTPStreamsTimeBelowLowThreshold             Integer32,
       acPMRTPStreamsTimeBetweenThresholds             Integer32,
       acPMRTPStreamsTimeAboveHighThreshold            Integer32,
       acPMRTPStreamsFullDayAverage                    Integer32
     }



     acPMRTPStreamsInterval OBJECT-TYPE
       SYNTAX Unsigned32 (0..2)
       MAX-ACCESS not-accessible
       STATUS current
       DESCRIPTION
           "Interval index.
0 - current period (incomplete monitoring - mid period).
1 - Last full period.
2 - One before last."
       ::= {acPMRTPStreamsEntry 1}



     acPMRTPStreamsVal OBJECT-TYPE
       SYNTAX Gauge32
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Value of gauge or counter."
       ::= {acPMRTPStreamsEntry 2}



     acPMRTPStreamsAverage OBJECT-TYPE
       SYNTAX Integer32 (-1..2147483647)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Average value within the period time."
       ::= {acPMRTPStreamsEntry 3}



     acPMRTPStreamsMax OBJECT-TYPE
       SYNTAX Integer32 (-1..2147483647)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Maximum value within the period time."
       ::= {acPMRTPStreamsEntry 4}



     acPMRTPStreamsMin OBJECT-TYPE
       SYNTAX Integer32 (-1..2147483647)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Minimum value within the period time."
       ::= {acPMRTPStreamsEntry 5}



     acPMRTPStreamsVolume OBJECT-TYPE
       SYNTAX Counter32
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Activity volume."
       ::= {acPMRTPStreamsEntry 6}



     acPMRTPStreamsTimeBelowLowThreshold OBJECT-TYPE
       SYNTAX Integer32 (-1..100)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Percent of interval time for which gauge is below what was determined
as the low threshold."
       ::= {acPMRTPStreamsEntry 7}



     acPMRTPStreamsTimeBetweenThresholds OBJECT-TYPE
       SYNTAX Integer32 (-1..100)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Percent of interval time for which gauge is above what was determined
as the high threshold."
       ::= {acPMRTPStreamsEntry 8}



     acPMRTPStreamsTimeAboveHighThreshold OBJECT-TYPE
       SYNTAX Integer32 (-1..100)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Percent of interval time for which gauge is between what were
determined as the low and high thresholds."
       ::= {acPMRTPStreamsEntry 9}



     acPMRTPStreamsFullDayAverage OBJECT-TYPE
       SYNTAX Integer32 (-1..2147483647)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "The average of full 24 hours."
       ::= {acPMRTPStreamsEntry 10}



     -- ****************************************
     -- acPMSRTPStreams table declaration
     -- ****************************************
     acPMSRTPStreamsTable OBJECT-TYPE
       SYNTAX SEQUENCE OF AcPMSRTPStreamsEntry
       MAX-ACCESS not-accessible
       STATUS current
       DESCRIPTION
           "Total number of active SRTP streams."
       ::= {acPMChannelUtilization 5}



     -- ****************************************
     -- acPMSRTPStreams table entry
     -- ****************************************
     acPMSRTPStreamsEntry OBJECT-TYPE
       SYNTAX AcPMSRTPStreamsEntry
       MAX-ACCESS not-accessible
       STATUS current
       DESCRIPTION
           ""
       INDEX {acPMSRTPStreamsInterval}
       ::= {acPMSRTPStreamsTable 1}



     -- ****************************************
     -- acPMSRTPStreams TABLE
     -- ****************************************
     AcPMSRTPStreamsEntry ::= SEQUENCE {
       acPMSRTPStreamsInterval                         Unsigned32,
       acPMSRTPStreamsVal                              Gauge32,
       acPMSRTPStreamsAverage                          Integer32,
       acPMSRTPStreamsMax                              Integer32,
       acPMSRTPStreamsMin                              Integer32,
       acPMSRTPStreamsVolume                           Counter32,
       acPMSRTPStreamsTimeBelowLowThreshold            Integer32,
       acPMSRTPStreamsTimeBetweenThresholds            Integer32,
       acPMSRTPStreamsTimeAboveHighThreshold           Integer32,
       acPMSRTPStreamsFullDayAverage                   Integer32
     }



     acPMSRTPStreamsInterval OBJECT-TYPE
       SYNTAX Unsigned32 (0..2)
       MAX-ACCESS not-accessible
       STATUS current
       DESCRIPTION
           "Interval index.
0 - current period (incomplete monitoring - mid period).
1 - Last full period.
2 - One before last."
       ::= {acPMSRTPStreamsEntry 1}



     acPMSRTPStreamsVal OBJECT-TYPE
       SYNTAX Gauge32
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Value of gauge or counter."
       ::= {acPMSRTPStreamsEntry 2}



     acPMSRTPStreamsAverage OBJECT-TYPE
       SYNTAX Integer32 (-1..2147483647)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Average value within the period time."
       ::= {acPMSRTPStreamsEntry 3}



     acPMSRTPStreamsMax OBJECT-TYPE
       SYNTAX Integer32 (-1..2147483647)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Maximum value within the period time."
       ::= {acPMSRTPStreamsEntry 4}



     acPMSRTPStreamsMin OBJECT-TYPE
       SYNTAX Integer32 (-1..2147483647)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Minimum value within the period time."
       ::= {acPMSRTPStreamsEntry 5}



     acPMSRTPStreamsVolume OBJECT-TYPE
       SYNTAX Counter32
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Activity volume."
       ::= {acPMSRTPStreamsEntry 6}



     acPMSRTPStreamsTimeBelowLowThreshold OBJECT-TYPE
       SYNTAX Integer32 (-1..100)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Percent of interval time for which gauge is below what was determined
as the low threshold."
       ::= {acPMSRTPStreamsEntry 7}



     acPMSRTPStreamsTimeBetweenThresholds OBJECT-TYPE
       SYNTAX Integer32 (-1..100)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Percent of interval time for which gauge is above what was determined
as the high threshold."
       ::= {acPMSRTPStreamsEntry 8}



     acPMSRTPStreamsTimeAboveHighThreshold OBJECT-TYPE
       SYNTAX Integer32 (-1..100)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Percent of interval time for which gauge is between what were
determined as the low and high thresholds."
       ::= {acPMSRTPStreamsEntry 9}



     acPMSRTPStreamsFullDayAverage OBJECT-TYPE
       SYNTAX Integer32 (-1..2147483647)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "The average of full 24 hours."
       ::= {acPMSRTPStreamsEntry 10}



     -- ****************************************
     -- acPMMulticastRegisteredChannels table declaration
     -- ****************************************
     acPMMulticastRegisteredChannelsTable OBJECT-TYPE
       SYNTAX SEQUENCE OF AcPMMulticastRegisteredChannelsEntry
       MAX-ACCESS not-accessible
       STATUS current
       DESCRIPTION
           "Total number of active channels connected to a multicast source."
       ::= {acPMChannelUtilization 6}



     -- ****************************************
     -- acPMMulticastRegisteredChannels table entry
     -- ****************************************
     acPMMulticastRegisteredChannelsEntry OBJECT-TYPE
       SYNTAX AcPMMulticastRegisteredChannelsEntry
       MAX-ACCESS not-accessible
       STATUS current
       DESCRIPTION
           ""
       INDEX {acPMMulticastRegisteredChannelsInterval}
       ::= {acPMMulticastRegisteredChannelsTable 1}



     -- ****************************************
     -- acPMMulticastRegisteredChannels TABLE
     -- ****************************************
     AcPMMulticastRegisteredChannelsEntry ::= SEQUENCE {
       acPMMulticastRegisteredChannelsInterval         Unsigned32,
       acPMMulticastRegisteredChannelsVal              Gauge32,
       acPMMulticastRegisteredChannelsAverage          Integer32,
       acPMMulticastRegisteredChannelsMax              Integer32,
       acPMMulticastRegisteredChannelsMin              Integer32,
       acPMMulticastRegisteredChannelsVolume           Counter32,
       acPMMulticastRegisteredChannelsTimeBelowLowThreshold 
                                                       Integer32,
       acPMMulticastRegisteredChannelsTimeBetweenThresholds 
                                                       Integer32,
       acPMMulticastRegisteredChannelsTimeAboveHighThreshold 
                                                       Integer32,
       acPMMulticastRegisteredChannelsFullDayAverage   Integer32
     }



     acPMMulticastRegisteredChannelsInterval OBJECT-TYPE
       SYNTAX Unsigned32 (0..2)
       MAX-ACCESS not-accessible
       STATUS current
       DESCRIPTION
           "Interval index.
0 - current period (incomplete monitoring - mid period).
1 - Last full period.
2 - One before last."
       ::= {acPMMulticastRegisteredChannelsEntry 1}



     acPMMulticastRegisteredChannelsVal OBJECT-TYPE
       SYNTAX Gauge32
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Value of gauge or counter."
       ::= {acPMMulticastRegisteredChannelsEntry 2}



     acPMMulticastRegisteredChannelsAverage OBJECT-TYPE
       SYNTAX Integer32 (-1..2147483647)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Average value within the period time."
       ::= {acPMMulticastRegisteredChannelsEntry 3}



     acPMMulticastRegisteredChannelsMax OBJECT-TYPE
       SYNTAX Integer32 (-1..2147483647)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Maximum value within the period time."
       ::= {acPMMulticastRegisteredChannelsEntry 4}



     acPMMulticastRegisteredChannelsMin OBJECT-TYPE
       SYNTAX Integer32 (-1..2147483647)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Minimum value within the period time."
       ::= {acPMMulticastRegisteredChannelsEntry 5}



     acPMMulticastRegisteredChannelsVolume OBJECT-TYPE
       SYNTAX Counter32
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Activity volume."
       ::= {acPMMulticastRegisteredChannelsEntry 6}



     acPMMulticastRegisteredChannelsTimeBelowLowThreshold OBJECT-TYPE
       SYNTAX Integer32 (-1..100)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Percent of interval time for which gauge is below what was determined
as the low threshold."
       ::= {acPMMulticastRegisteredChannelsEntry 7}



     acPMMulticastRegisteredChannelsTimeBetweenThresholds OBJECT-TYPE
       SYNTAX Integer32 (-1..100)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Percent of interval time for which gauge is above what was determined
as the high threshold."
       ::= {acPMMulticastRegisteredChannelsEntry 8}



     acPMMulticastRegisteredChannelsTimeAboveHighThreshold OBJECT-TYPE
       SYNTAX Integer32 (-1..100)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Percent of interval time for which gauge is between what were
determined as the low and high thresholds."
       ::= {acPMMulticastRegisteredChannelsEntry 9}



     acPMMulticastRegisteredChannelsFullDayAverage OBJECT-TYPE
       SYNTAX Integer32 (-1..2147483647)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "The average of full 24 hours."
       ::= {acPMMulticastRegisteredChannelsEntry 10}



     -- ****************************************
     -- acPMModemRelayActiveChannels table declaration
     -- ****************************************
     acPMModemRelayActiveChannelsTable OBJECT-TYPE
       SYNTAX SEQUENCE OF AcPMModemRelayActiveChannelsEntry
       MAX-ACCESS not-accessible
       STATUS current
       DESCRIPTION
           "Number of active modem relay (V150.1) channels."
       ::= {acPMChannelUtilization 7}



     -- ****************************************
     -- acPMModemRelayActiveChannels table entry
     -- ****************************************
     acPMModemRelayActiveChannelsEntry OBJECT-TYPE
       SYNTAX AcPMModemRelayActiveChannelsEntry
       MAX-ACCESS not-accessible
       STATUS current
       DESCRIPTION
           ""
       INDEX {acPMModemRelayActiveChannelsInterval}
       ::= {acPMModemRelayActiveChannelsTable 1}



     -- ****************************************
     -- acPMModemRelayActiveChannels TABLE
     -- ****************************************
     AcPMModemRelayActiveChannelsEntry ::= SEQUENCE {
       acPMModemRelayActiveChannelsInterval            Unsigned32,
       acPMModemRelayActiveChannelsVal                 Gauge32,
       acPMModemRelayActiveChannelsAverage             Integer32,
       acPMModemRelayActiveChannelsMax                 Integer32,
       acPMModemRelayActiveChannelsMin                 Integer32,
       acPMModemRelayActiveChannelsVolume              Counter32,
       acPMModemRelayActiveChannelsTimeBelowLowThreshold 
                                                       Integer32,
       acPMModemRelayActiveChannelsTimeBetweenThresholds 
                                                       Integer32,
       acPMModemRelayActiveChannelsTimeAboveHighThreshold 
                                                       Integer32,
       acPMModemRelayActiveChannelsFullDayAverage      Integer32
     }



     acPMModemRelayActiveChannelsInterval OBJECT-TYPE
       SYNTAX Unsigned32 (0..2)
       MAX-ACCESS not-accessible
       STATUS current
       DESCRIPTION
           "Interval index.
0 - current period (incomplete monitoring - mid period).
1 - Last full period.
2 - One before last."
       ::= {acPMModemRelayActiveChannelsEntry 1}



     acPMModemRelayActiveChannelsVal OBJECT-TYPE
       SYNTAX Gauge32
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Value of gauge or counter."
       ::= {acPMModemRelayActiveChannelsEntry 2}



     acPMModemRelayActiveChannelsAverage OBJECT-TYPE
       SYNTAX Integer32 (-1..2147483647)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Average value within the period time."
       ::= {acPMModemRelayActiveChannelsEntry 3}



     acPMModemRelayActiveChannelsMax OBJECT-TYPE
       SYNTAX Integer32 (-1..2147483647)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Maximum value within the period time."
       ::= {acPMModemRelayActiveChannelsEntry 4}



     acPMModemRelayActiveChannelsMin OBJECT-TYPE
       SYNTAX Integer32 (-1..2147483647)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Minimum value within the period time."
       ::= {acPMModemRelayActiveChannelsEntry 5}



     acPMModemRelayActiveChannelsVolume OBJECT-TYPE
       SYNTAX Counter32
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Activity volume."
       ::= {acPMModemRelayActiveChannelsEntry 6}



     acPMModemRelayActiveChannelsTimeBelowLowThreshold OBJECT-TYPE
       SYNTAX Integer32 (-1..100)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Percent of interval time for which gauge is below what was determined
as the low threshold."
       ::= {acPMModemRelayActiveChannelsEntry 7}



     acPMModemRelayActiveChannelsTimeBetweenThresholds OBJECT-TYPE
       SYNTAX Integer32 (-1..100)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Percent of interval time for which gauge is above what was determined
as the high threshold."
       ::= {acPMModemRelayActiveChannelsEntry 8}



     acPMModemRelayActiveChannelsTimeAboveHighThreshold OBJECT-TYPE
       SYNTAX Integer32 (-1..100)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Percent of interval time for which gauge is between what were
determined as the low and high thresholds."
       ::= {acPMModemRelayActiveChannelsEntry 9}



     acPMModemRelayActiveChannelsFullDayAverage OBJECT-TYPE
       SYNTAX Integer32 (-1..2147483647)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "The average of full 24 hours."
       ::= {acPMModemRelayActiveChannelsEntry 10}



     acPMStreamingCache OBJECT IDENTIFIER ::= {acPMMediaData 42}


     -- ****************************************
     -- acPMStreamingCacheHitRate table declaration
     -- ****************************************
     acPMStreamingCacheHitRateTable OBJECT-TYPE
       SYNTAX SEQUENCE OF AcPMStreamingCacheHitRateEntry
       MAX-ACCESS not-accessible
       STATUS current
       DESCRIPTION
           "Hit count rate of streaming cache"
       ::= {acPMStreamingCache 1}



     -- ****************************************
     -- acPMStreamingCacheHitRate table entry
     -- ****************************************
     acPMStreamingCacheHitRateEntry OBJECT-TYPE
       SYNTAX AcPMStreamingCacheHitRateEntry
       MAX-ACCESS not-accessible
       STATUS current
       DESCRIPTION
           ""
       INDEX {acPMStreamingCacheHitRateInterval}
       ::= {acPMStreamingCacheHitRateTable 1}



     -- ****************************************
     -- acPMStreamingCacheHitRate TABLE
     -- ****************************************
     AcPMStreamingCacheHitRateEntry ::= SEQUENCE {
       acPMStreamingCacheHitRateInterval               Unsigned32,
       acPMStreamingCacheHitRateAverage                Integer32,
       acPMStreamingCacheHitRateMax                    Integer32,
       acPMStreamingCacheHitRateMin                    Integer32,
       acPMStreamingCacheHitRateVolume                 Counter32,
       acPMStreamingCacheHitRateTimeBelowLowThreshold  Integer32,
       acPMStreamingCacheHitRateTimeBetweenThresholds  Integer32,
       acPMStreamingCacheHitRateTimeAboveHighThreshold Integer32,
       acPMStreamingCacheHitRateFullDayAverage         Integer32
     }



     acPMStreamingCacheHitRateInterval OBJECT-TYPE
       SYNTAX Unsigned32 (0..2)
       MAX-ACCESS not-accessible
       STATUS current
       DESCRIPTION
           "Interval index.
0 - current period (incomplete monitoring - mid period).
1 - Last full period.
2 - One before last."
       ::= {acPMStreamingCacheHitRateEntry 1}



     acPMStreamingCacheHitRateAverage OBJECT-TYPE
       SYNTAX Integer32 (-1..2147483647)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Average value within the period time."
       ::= {acPMStreamingCacheHitRateEntry 2}



     acPMStreamingCacheHitRateMax OBJECT-TYPE
       SYNTAX Integer32 (-1..2147483647)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Maximum value within the period time."
       ::= {acPMStreamingCacheHitRateEntry 3}



     acPMStreamingCacheHitRateMin OBJECT-TYPE
       SYNTAX Integer32 (-1..2147483647)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Minimum value within the period time."
       ::= {acPMStreamingCacheHitRateEntry 4}



     acPMStreamingCacheHitRateVolume OBJECT-TYPE
       SYNTAX Counter32
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Activity volume."
       ::= {acPMStreamingCacheHitRateEntry 5}



     acPMStreamingCacheHitRateTimeBelowLowThreshold OBJECT-TYPE
       SYNTAX Integer32 (-1..100)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Percent of interval time for which gauge is below what was determined
as the low threshold."
       ::= {acPMStreamingCacheHitRateEntry 6}



     acPMStreamingCacheHitRateTimeBetweenThresholds OBJECT-TYPE
       SYNTAX Integer32 (-1..100)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Percent of interval time for which gauge is above what was determined
as the high threshold."
       ::= {acPMStreamingCacheHitRateEntry 7}



     acPMStreamingCacheHitRateTimeAboveHighThreshold OBJECT-TYPE
       SYNTAX Integer32 (-1..100)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Percent of interval time for which gauge is between what were
determined as the low and high thresholds."
       ::= {acPMStreamingCacheHitRateEntry 8}



     acPMStreamingCacheHitRateFullDayAverage OBJECT-TYPE
       SYNTAX Integer32 (-1..2147483647)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "The average of full 24 hours."
       ::= {acPMStreamingCacheHitRateEntry 9}



     -- ****************************************
     -- acPMStreamingCacheMissRate table declaration
     -- ****************************************
     acPMStreamingCacheMissRateTable OBJECT-TYPE
       SYNTAX SEQUENCE OF AcPMStreamingCacheMissRateEntry
       MAX-ACCESS not-accessible
       STATUS current
       DESCRIPTION
           "Miss count rate of streaming cache"
       ::= {acPMStreamingCache 2}



     -- ****************************************
     -- acPMStreamingCacheMissRate table entry
     -- ****************************************
     acPMStreamingCacheMissRateEntry OBJECT-TYPE
       SYNTAX AcPMStreamingCacheMissRateEntry
       MAX-ACCESS not-accessible
       STATUS current
       DESCRIPTION
           ""
       INDEX {acPMStreamingCacheMissRateInterval}
       ::= {acPMStreamingCacheMissRateTable 1}



     -- ****************************************
     -- acPMStreamingCacheMissRate TABLE
     -- ****************************************
     AcPMStreamingCacheMissRateEntry ::= SEQUENCE {
       acPMStreamingCacheMissRateInterval              Unsigned32,
       acPMStreamingCacheMissRateAverage               Integer32,
       acPMStreamingCacheMissRateMax                   Integer32,
       acPMStreamingCacheMissRateMin                   Integer32,
       acPMStreamingCacheMissRateVolume                Counter32,
       acPMStreamingCacheMissRateTimeBelowLowThreshold Integer32,
       acPMStreamingCacheMissRateTimeBetweenThresholds Integer32,
       acPMStreamingCacheMissRateTimeAboveHighThreshold 
                                                       Integer32,
       acPMStreamingCacheMissRateFullDayAverage        Integer32
     }



     acPMStreamingCacheMissRateInterval OBJECT-TYPE
       SYNTAX Unsigned32 (0..2)
       MAX-ACCESS not-accessible
       STATUS current
       DESCRIPTION
           "Interval index.
0 - current period (incomplete monitoring - mid period).
1 - Last full period.
2 - One before last."
       ::= {acPMStreamingCacheMissRateEntry 1}



     acPMStreamingCacheMissRateAverage OBJECT-TYPE
       SYNTAX Integer32 (-1..2147483647)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Average value within the period time."
       ::= {acPMStreamingCacheMissRateEntry 2}



     acPMStreamingCacheMissRateMax OBJECT-TYPE
       SYNTAX Integer32 (-1..2147483647)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Maximum value within the period time."
       ::= {acPMStreamingCacheMissRateEntry 3}



     acPMStreamingCacheMissRateMin OBJECT-TYPE
       SYNTAX Integer32 (-1..2147483647)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Minimum value within the period time."
       ::= {acPMStreamingCacheMissRateEntry 4}



     acPMStreamingCacheMissRateVolume OBJECT-TYPE
       SYNTAX Counter32
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Activity volume."
       ::= {acPMStreamingCacheMissRateEntry 5}



     acPMStreamingCacheMissRateTimeBelowLowThreshold OBJECT-TYPE
       SYNTAX Integer32 (-1..100)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Percent of interval time for which gauge is below what was determined
as the low threshold."
       ::= {acPMStreamingCacheMissRateEntry 6}



     acPMStreamingCacheMissRateTimeBetweenThresholds OBJECT-TYPE
       SYNTAX Integer32 (-1..100)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Percent of interval time for which gauge is above what was determined
as the high threshold."
       ::= {acPMStreamingCacheMissRateEntry 7}



     acPMStreamingCacheMissRateTimeAboveHighThreshold OBJECT-TYPE
       SYNTAX Integer32 (-1..100)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Percent of interval time for which gauge is between what were
determined as the low and high thresholds."
       ::= {acPMStreamingCacheMissRateEntry 8}



     acPMStreamingCacheMissRateFullDayAverage OBJECT-TYPE
       SYNTAX Integer32 (-1..2147483647)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "The average of full 24 hours."
       ::= {acPMStreamingCacheMissRateEntry 9}



     -- ****************************************
     -- acPMStreamingCacheServerRequestsRate table declaration
     -- ****************************************
     acPMStreamingCacheServerRequestsRateTable OBJECT-TYPE
       SYNTAX SEQUENCE OF AcPMStreamingCacheServerRequestsRateEntry
       MAX-ACCESS not-accessible
       STATUS current
       DESCRIPTION
           "Server requests count rate of streaming cache"
       ::= {acPMStreamingCache 3}



     -- ****************************************
     -- acPMStreamingCacheServerRequestsRate table entry
     -- ****************************************
     acPMStreamingCacheServerRequestsRateEntry OBJECT-TYPE
       SYNTAX AcPMStreamingCacheServerRequestsRateEntry
       MAX-ACCESS not-accessible
       STATUS current
       DESCRIPTION
           ""
       INDEX {acPMStreamingCacheServerRequestsRateInterval}
       ::= {acPMStreamingCacheServerRequestsRateTable 1}



     -- ****************************************
     -- acPMStreamingCacheServerRequestsRate TABLE
     -- ****************************************
     AcPMStreamingCacheServerRequestsRateEntry ::= SEQUENCE {
       acPMStreamingCacheServerRequestsRateInterval    Unsigned32,
       acPMStreamingCacheServerRequestsRateAverage     Integer32,
       acPMStreamingCacheServerRequestsRateMax         Integer32,
       acPMStreamingCacheServerRequestsRateMin         Integer32,
       acPMStreamingCacheServerRequestsRateVolume      Counter32,
       acPMStreamingCacheServerRequestsRateTimeBelowLowThreshold 
                                                       Integer32,
       acPMStreamingCacheServerRequestsRateTimeBetweenThresholds 
                                                       Integer32,
       acPMStreamingCacheServerRequestsRateTimeAboveHighThreshold 
                                                       Integer32,
       acPMStreamingCacheServerRequestsRateFullDayAverage 
                                                       Integer32
     }



     acPMStreamingCacheServerRequestsRateInterval OBJECT-TYPE
       SYNTAX Unsigned32 (0..2)
       MAX-ACCESS not-accessible
       STATUS current
       DESCRIPTION
           "Interval index.
0 - current period (incomplete monitoring - mid period).
1 - Last full period.
2 - One before last."
       ::= {acPMStreamingCacheServerRequestsRateEntry 1}



     acPMStreamingCacheServerRequestsRateAverage OBJECT-TYPE
       SYNTAX Integer32 (-1..2147483647)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Average value within the period time."
       ::= {acPMStreamingCacheServerRequestsRateEntry 2}



     acPMStreamingCacheServerRequestsRateMax OBJECT-TYPE
       SYNTAX Integer32 (-1..2147483647)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Maximum value within the period time."
       ::= {acPMStreamingCacheServerRequestsRateEntry 3}



     acPMStreamingCacheServerRequestsRateMin OBJECT-TYPE
       SYNTAX Integer32 (-1..2147483647)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Minimum value within the period time."
       ::= {acPMStreamingCacheServerRequestsRateEntry 4}



     acPMStreamingCacheServerRequestsRateVolume OBJECT-TYPE
       SYNTAX Counter32
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Activity volume."
       ::= {acPMStreamingCacheServerRequestsRateEntry 5}



     acPMStreamingCacheServerRequestsRateTimeBelowLowThreshold OBJECT-TYPE
       SYNTAX Integer32 (-1..100)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Percent of interval time for which gauge is below what was determined
as the low threshold."
       ::= {acPMStreamingCacheServerRequestsRateEntry 6}



     acPMStreamingCacheServerRequestsRateTimeBetweenThresholds OBJECT-TYPE
       SYNTAX Integer32 (-1..100)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Percent of interval time for which gauge is above what was determined
as the high threshold."
       ::= {acPMStreamingCacheServerRequestsRateEntry 7}



     acPMStreamingCacheServerRequestsRateTimeAboveHighThreshold OBJECT-TYPE
       SYNTAX Integer32 (-1..100)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Percent of interval time for which gauge is between what were
determined as the low and high thresholds."
       ::= {acPMStreamingCacheServerRequestsRateEntry 8}



     acPMStreamingCacheServerRequestsRateFullDayAverage OBJECT-TYPE
       SYNTAX Integer32 (-1..2147483647)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "The average of full 24 hours."
       ::= {acPMStreamingCacheServerRequestsRateEntry 9}



     acPMModemRelay OBJECT IDENTIFIER ::= {acPMMediaData 43}


     -- ****************************************
     -- acPMModemRelaySessionRequests table declaration
     -- ****************************************
     acPMModemRelaySessionRequestsTable OBJECT-TYPE
       SYNTAX SEQUENCE OF AcPMModemRelaySessionRequestsEntry
       MAX-ACCESS not-accessible
       STATUS current
       DESCRIPTION
           "Number of modem relay (V150.1) session requests."
       ::= {acPMModemRelay 1}



     -- ****************************************
     -- acPMModemRelaySessionRequests table entry
     -- ****************************************
     acPMModemRelaySessionRequestsEntry OBJECT-TYPE
       SYNTAX AcPMModemRelaySessionRequestsEntry
       MAX-ACCESS not-accessible
       STATUS current
       DESCRIPTION
           ""
       INDEX {acPMModemRelaySessionRequestsInterval}
       ::= {acPMModemRelaySessionRequestsTable 1}



     -- ****************************************
     -- acPMModemRelaySessionRequests TABLE
     -- ****************************************
     AcPMModemRelaySessionRequestsEntry ::= SEQUENCE {
       acPMModemRelaySessionRequestsInterval           Unsigned32,
       acPMModemRelaySessionRequestsAverage            Integer32,
       acPMModemRelaySessionRequestsMax                Integer32,
       acPMModemRelaySessionRequestsMin                Integer32,
       acPMModemRelaySessionRequestsVal                Gauge32,
       acPMModemRelaySessionRequestsFullDayAverage     Integer32
     }



     acPMModemRelaySessionRequestsInterval OBJECT-TYPE
       SYNTAX Unsigned32 (0..2)
       MAX-ACCESS not-accessible
       STATUS current
       DESCRIPTION
           "Interval index.
0 - current period (incomplete monitoring - mid period).
1 - Last full period.
2 - One before last."
       ::= {acPMModemRelaySessionRequestsEntry 1}



     acPMModemRelaySessionRequestsAverage OBJECT-TYPE
       SYNTAX Integer32 (-1..2147483647)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Average value within the period time."
       ::= {acPMModemRelaySessionRequestsEntry 2}



     acPMModemRelaySessionRequestsMax OBJECT-TYPE
       SYNTAX Integer32 (-1..2147483647)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Maximum value within the period time."
       ::= {acPMModemRelaySessionRequestsEntry 3}



     acPMModemRelaySessionRequestsMin OBJECT-TYPE
       SYNTAX Integer32 (-1..2147483647)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Minimum value within the period time."
       ::= {acPMModemRelaySessionRequestsEntry 4}



     acPMModemRelaySessionRequestsVal OBJECT-TYPE
       SYNTAX Gauge32
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Value of gauge or counter."
       ::= {acPMModemRelaySessionRequestsEntry 5}



     acPMModemRelaySessionRequestsFullDayAverage OBJECT-TYPE
       SYNTAX Integer32 (-1..2147483647)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "The average of full 24 hours."
       ::= {acPMModemRelaySessionRequestsEntry 6}



     -- ****************************************
     -- acPMModemRelaySessionRejections table declaration
     -- ****************************************
     acPMModemRelaySessionRejectionsTable OBJECT-TYPE
       SYNTAX SEQUENCE OF AcPMModemRelaySessionRejectionsEntry
       MAX-ACCESS not-accessible
       STATUS current
       DESCRIPTION
           "Number of modem relay (V150.1) session rejections due to lack of resources."
       ::= {acPMModemRelay 2}



     -- ****************************************
     -- acPMModemRelaySessionRejections table entry
     -- ****************************************
     acPMModemRelaySessionRejectionsEntry OBJECT-TYPE
       SYNTAX AcPMModemRelaySessionRejectionsEntry
       MAX-ACCESS not-accessible
       STATUS current
       DESCRIPTION
           ""
       INDEX {acPMModemRelaySessionRejectionsInterval}
       ::= {acPMModemRelaySessionRejectionsTable 1}



     -- ****************************************
     -- acPMModemRelaySessionRejections TABLE
     -- ****************************************
     AcPMModemRelaySessionRejectionsEntry ::= SEQUENCE {
       acPMModemRelaySessionRejectionsInterval         Unsigned32,
       acPMModemRelaySessionRejectionsAverage          Integer32,
       acPMModemRelaySessionRejectionsMax              Integer32,
       acPMModemRelaySessionRejectionsMin              Integer32,
       acPMModemRelaySessionRejectionsVal              Gauge32,
       acPMModemRelaySessionRejectionsTimeBetweenThresholds 
                                                       Integer32,
       acPMModemRelaySessionRejectionsTimeAboveHighThreshold 
                                                       Integer32,
       acPMModemRelaySessionRejectionsFullDayAverage   Integer32
     }



     acPMModemRelaySessionRejectionsInterval OBJECT-TYPE
       SYNTAX Unsigned32 (0..2)
       MAX-ACCESS not-accessible
       STATUS current
       DESCRIPTION
           "Interval index.
0 - current period (incomplete monitoring - mid period).
1 - Last full period.
2 - One before last."
       ::= {acPMModemRelaySessionRejectionsEntry 1}



     acPMModemRelaySessionRejectionsAverage OBJECT-TYPE
       SYNTAX Integer32 (-1..2147483647)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Average value within the period time."
       ::= {acPMModemRelaySessionRejectionsEntry 2}



     acPMModemRelaySessionRejectionsMax OBJECT-TYPE
       SYNTAX Integer32 (-1..2147483647)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Maximum value within the period time."
       ::= {acPMModemRelaySessionRejectionsEntry 3}



     acPMModemRelaySessionRejectionsMin OBJECT-TYPE
       SYNTAX Integer32 (-1..2147483647)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Minimum value within the period time."
       ::= {acPMModemRelaySessionRejectionsEntry 4}



     acPMModemRelaySessionRejectionsVal OBJECT-TYPE
       SYNTAX Gauge32
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Value of gauge or counter."
       ::= {acPMModemRelaySessionRejectionsEntry 5}



     acPMModemRelaySessionRejectionsTimeBetweenThresholds OBJECT-TYPE
       SYNTAX Integer32 (-1..100)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Percent of interval time for which gauge is above what was determined
as the high threshold."
       ::= {acPMModemRelaySessionRejectionsEntry 6}



     acPMModemRelaySessionRejectionsTimeAboveHighThreshold OBJECT-TYPE
       SYNTAX Integer32 (-1..100)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Percent of interval time for which gauge is between what were
determined as the low and high thresholds."
       ::= {acPMModemRelaySessionRejectionsEntry 7}



     acPMModemRelaySessionRejectionsFullDayAverage OBJECT-TYPE
       SYNTAX Integer32 (-1..2147483647)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "The average of full 24 hours."
       ::= {acPMModemRelaySessionRejectionsEntry 8}





END