-- Emerson Energy Systems (EES)
-- Power MIB
------------------------------------------------------------

EES-POWER-MIB DEFINITIONS ::= BEGIN


IMPORTS
	MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE,
	Integer32, Counter32, enterprises
		FROM SNMPv2-SMI
	TEXTUAL-CONVENTION, DisplayString, DateAndTime
		FROM SNMPv2-TC;
		
		
powerMIB MODULE-IDENTITY
	LAST-UPDATED "201504100857Z"
	ORGANIZATION "
		Emerson Energy Systems (EES)"
	CONTACT-INFO "
		Emerson Energy Systems
		141 82 Stockholm
		Sweden"
	DESCRIPTION "
		Emerson Energy Systems (EES) Power MIB, revision D."
	::= { enterprises 6302 2 1 }

------------------------------------------------------------
-- Node definitions
------------------------------------------------------------

ees OBJECT IDENTIFIER ::= { enterprises 6302 }

global OBJECT IDENTIFIER ::= { ees 2 }

------------------------------------------------------------
-- Textual conventions
------------------------------------------------------------

Status ::= TEXTUAL-CONVENTION
	STATUS current
	DESCRIPTION "
		This integer value represents the operational or administrative
		status of the system. Also used as alarm severity.
		Depending on situation there may be limits on allowed values.
		Operational values:
		(1) unknown - status has not yet been defined
		(2) normal - there are no activated alarms
		(3) warning - OA, lowest level of 'abnormal' status
		(4) minor - A3
		(5) major - MA
		(6) critical - CA, highest level of 'abnormal' status
		Administrative values:
		(7) unmanaged
		(8) restricted
		(9) testing
		(10) disabled"
	SYNTAX INTEGER {
		unknown(1),
		normal(2),
		warning(3),
		minor(4),
		major(5),
		critical(6),
		unmanaged(7),
		restricted(8),
		testing(9),
		disabled(10) }

StatusChange ::= TEXTUAL-CONVENTION
	STATUS current
	DESCRIPTION "
		Indicates 'activated' (1) or 'deactivated' (2) alarm events."
	SYNTAX INTEGER {
		activated(1),
		deactivated(2) }


------------------------------------------------------------
-- 1.1 Identification of the plant { powerMIB 1 }
------------------------------------------------------------

ident OBJECT IDENTIFIER ::= { powerMIB 1 }

identManufacturer OBJECT-TYPE
	SYNTAX DisplayString
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION "
		The name of the equipment manufacturer."
	::= { ident 1 }

identModel OBJECT-TYPE
	SYNTAX DisplayString
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION "
		The manufacturers model designation of the power system."
	::= { ident 2 }

identControllerFirmwareVersion OBJECT-TYPE
	SYNTAX DisplayString
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION "
		The firmware (software) version of the controller."
	::= { ident 3 }

identName OBJECT-TYPE
	SYNTAX DisplayString
	MAX-ACCESS read-write
	STATUS current
	DESCRIPTION "
		The name of the power plant. This object should be set by
		the administrator."
	::= { ident 4 }

identSNMPCfgVer OBJECT-TYPE
	SYNTAX DisplayString
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION "
		The snmp cfg version"
	::= { ident 5 }
	
identControllerSerialNumber OBJECT-TYPE
	SYNTAX DisplayString
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION "
		The serial number of this controller"
	::= { ident 6 }	
	
------------------------------------------------------------
-- 1.2 System values { powerMIB 2 }
------------------------------------------------------------

system OBJECT IDENTIFIER ::= { powerMIB 2 }

systemStatus OBJECT-TYPE
	SYNTAX Status
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION "
		Status of the complete plant (highest alarm). One of
		(1) unknown - status has not yet been defined
		(2) normal - there are no activated alarms
		(3) warning - OA, lowest level of 'abnormal' status
		(4) minor - A3
		(5) major - MA
		(6) critical - CA, highest level of 'abnormal' status
		(7) unmanaged
		(8) restricted
		(9) testing
		(10) disabled"
	::= { system 1 }

systemVoltage OBJECT-TYPE
	SYNTAX Integer32
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION "
		System voltage, stored as mV, including positive or negative
		sign. The integer 2147483647 represents invalid value."
	::= { system 2 }

systemCurrent OBJECT-TYPE
	SYNTAX Integer32
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION "
		System current, stored as mA, including positive or negative
		sign. The integer 2147483647 represents invalid value."
	::= { system 3 }

systemUsedCapacity OBJECT-TYPE
	SYNTAX Integer32
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION "
		Used capacity, stored as % of the total capacity.
		The integer 2147483647 represents invalid value."
	::= { system 4 }



-- ------------------------------------------------------------------------ 
-- 1.2.5. Battery group
-- ------------------------------------------------------------------------ 

psBattery OBJECT IDENTIFIER ::= { system 5 }

    psBatteryVoltage OBJECT-TYPE
        SYNTAX Integer32
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
            "Battery voltage, stored as mV, including positive or negative
		sign. The integer 2147483647 represents invalid value."
        ::= { psBattery 1 }
    
    psTotalBatteryCurrent OBJECT-TYPE
        SYNTAX Integer32
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
            "Battery current, stored as mA, including positive or negative
		sign. The integer 2147483647 represents invalid value."
        ::= { psBattery 2 }

	psBatteryCapacity OBJECT-TYPE
		SYNTAX Integer32
		MAX-ACCESS read-only
		STATUS current
		DESCRIPTION "
			Calculated capacity, stored as % of the total capacity.
			The integer 2147483647 represents invalid value."
		::= { psBattery 3 }

	psBatteryNominalCapacity OBJECT-TYPE
		SYNTAX Integer32
		MAX-ACCESS read-only
		STATUS current
		DESCRIPTION "
			nominal installed capacity, stored as mAh.
			The integer 2147483647 represents invalid value."
		::= { psBattery 4 }

    psBatteryTable OBJECT-TYPE
        SYNTAX SEQUENCE OF PSBatteryEntry
        MAX-ACCESS not-accessible
        STATUS current
        DESCRIPTION     
                "Battery Table."
    ::= { psBattery 5 }
    
    psBatteryEntry OBJECT-TYPE
        SYNTAX PSBatteryEntry
        MAX-ACCESS not-accessible
        STATUS current
        DESCRIPTION
            "Battery Measurement Table Entry."
        INDEX { psBatteryIndex }
    ::= { psBatteryTable 1 }

    PSBatteryEntry ::= SEQUENCE {
        psBatteryIndex              Integer32,
        psBatteryCurrent         	Integer32,
        psBatteryName		  		DisplayString
    }

    psBatteryIndex OBJECT-TYPE
        SYNTAX		  Integer32(1..16777215)
        MAX-ACCESS              read-only
        STATUS                  current
        DESCRIPTION
                "Automatically generated index object."
    ::= { psBatteryEntry 1 }

    psBatteryCurrent OBJECT-TYPE
        SYNTAX 		  Integer32
        MAX-ACCESS              read-only
        STATUS                  current
        DESCRIPTION
                "Battery current in Amps."
    ::= { psBatteryEntry 2 }

    psBatteryName OBJECT-TYPE
        SYNTAX 		  DisplayString
        MAX-ACCESS              read-only
        STATUS                  current
        DESCRIPTION
                "Battery shunt name."
    ::= { psBatteryEntry 3 }


-- ------------------------------------------------------------------------ 
-- 1.2.6. the psInput group
-- ------------------------------------------------------------------------ 

psInput OBJECT IDENTIFIER ::= { system 6 }

    psInputLineAVoltage OBJECT-TYPE
        SYNTAX Integer32
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
            "The AC line A voltage, stored as mV. The integer 2147483647 
		represents invalid value."
        ::= { psInput 1 }

    psInputLineBVoltage OBJECT-TYPE
        SYNTAX Integer32
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
            "The AC line B voltage, stored as mV. The integer 2147483647 
		represents invalid value."
        ::= { psInput 2 }

    psInputLineCVoltage OBJECT-TYPE
        SYNTAX Integer32
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
            "The AC line C voltage, stored as mV. The integer 2147483647 
		represents invalid value."
        ::= { psInput 3 }

-- ------------------------------------------------------------------------ 
-- 1.2.7. the temperatures
-- ------------------------------------------------------------------------ 

psTemperature OBJECT IDENTIFIER ::= { system 7 }

    psTemperature1 OBJECT-TYPE
        SYNTAX Integer32
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
            "The first route temperature, stored as 0.001 Celsius degree. 
		The integer 2147483647 represents invalid value."
        ::= { psTemperature 1 }

    psTemperature2 OBJECT-TYPE
        SYNTAX Integer32
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
            "The second route temperature, stored as 0.001 Celsius degree. 
		The integer 2147483647 represents invalid value.."
        ::= { psTemperature 2 }


    psTemperatureTable OBJECT-TYPE
        SYNTAX SEQUENCE OF PSTemperatureEntry
        MAX-ACCESS not-accessible
        STATUS current
        DESCRIPTION     
                "Temperature Measurement Table."
    ::= { psTemperature 3 }
    
    psTemperatureEntry OBJECT-TYPE
        SYNTAX PSTemperatureEntry
        MAX-ACCESS not-accessible
        STATUS current
        DESCRIPTION
            "Temperature Measurement Table Entry."
        INDEX { psTemperatureIndex }
    ::= { psTemperatureTable 1 }

    PSTemperatureEntry ::= SEQUENCE {
        psTemperatureIndex               Integer32,
        psTemperatureMeasurement         Integer32,
        psTemperatureName                DisplayString,
        psTemperatureType                INTEGER,	
        psTemperatureAlarmStatus         INTEGER
    }

    psTemperatureIndex OBJECT-TYPE
        SYNTAX Integer32(1..71)
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
                "Temperature Probe Number "
    ::= { psTemperatureEntry 1 }

    psTemperatureMeasurement OBJECT-TYPE
        SYNTAX Integer32
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
                "Temperature Value In Centigrade."
    ::= { psTemperatureEntry 2 }

    psTemperatureName OBJECT-TYPE
        SYNTAX DisplayString
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
                "Configured Temperature Probe Name."
    ::= { psTemperatureEntry 3 }

    psTemperatureType OBJECT-TYPE
        SYNTAX INTEGER { 
        none(0), 
        ambient(1), 
        battery(2) 
        }
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
                "Temperature Probe Type "
    ::= { psTemperatureEntry 4 }

    psTemperatureAlarmStatus OBJECT-TYPE
        SYNTAX INTEGER { 
        high(0), 
        low(1), 
        fail(2), 
        none(3) 
        }
        MAX-ACCESS                  read-only
        STATUS                  current
        DESCRIPTION
                "Temperature Probe Alarm Status "
    ::= { psTemperatureEntry 5 }

psStatusCommunication OBJECT-TYPE
        SYNTAX INTEGER {
            unknown(1),
            normal(2),
            interrupt(3)
        }
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
            "The status of communication with the Power System. interrupt(3) indicates
             some errors occurred between Power System and agent."
        ::= { system 8 }

psStatusBatteryMode OBJECT-TYPE
        SYNTAX INTEGER  {
	    unknown(1),
	    floatCharging(2),
	    shortTest(3),
	    bcForTest(4),
	    manualTesting(5),
	    planTesting(6),
	    acFailTesting(7),
	    acFail(8),
	    manualBC(9),
	    autoBC(10),
	    cyclicBC(11),
	    masterBC(12),
	    masterBT(13)
	}
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
            "The status of battery modes, 
		FloatCharging(2),
		ShortTest(3),
		BoostChargingForTest(4),
		ManualTesting(5),
		PlanTesting(6),
		ACFailTesting(7),
		ACFail(8),
		ManualBoostCharging(9),
		AutoBoostCharging(10),
		CyclicBoostCharging(11),
		MasterBoostCharging(12),
		MasterBateryTesting(13)."
        ::= { system 9 }

-- ------------------------------------------------------------------------ 
-- 1.2.10. the SM series group(only get number of SM series)
-- ------------------------------------------------------------------------ 

psSMNumber OBJECT IDENTIFIER ::= { system 10 }

    psSMACNumber OBJECT-TYPE
        SYNTAX Integer32
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
            "The number of SM AC module."
        ::= { psSMNumber 1 }

    psSMBATNumber OBJECT-TYPE
        SYNTAX Integer32
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
            "The number of SM BAT module."
        ::= { psSMNumber 2 }

    psSMIONumber OBJECT-TYPE
        SYNTAX Integer32
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
            "The number of SM IO module."
        ::= { psSMNumber 3 }

-- ------------------------------------------------------------------------ 
-- 1.2.11. Rectifier group
-- ------------------------------------------------------------------------ 

psRectifier OBJECT IDENTIFIER ::= { system 11 }

numberOfInstalledRectifiers OBJECT-TYPE
	SYNTAX Integer32
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION "
		number of rectifiers, stored as integer.
		The integer 2147483647 represents invalid value."
	::= { psRectifier 1 }

numberOfRectifiersCommunicating OBJECT-TYPE
	SYNTAX Integer32
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION "
		number of rectifiers communicating, stored as integer.
		The integer 2147483647 represents invalid value."
	::= { psRectifier 2 }

rectifiersUsedCapacity OBJECT-TYPE
	SYNTAX Integer32
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION "
		Used capacity, stored as % of the total capacity.
		The integer 2147483647 represents invalid value."
	::= { psRectifier 3 }

psRectifierTable OBJECT-TYPE
	SYNTAX SEQUENCE OF PSRectifierEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION "
		Table holding information about indivual rectifiers."
	::= { psRectifier 4 }

psRectifierEntry OBJECT-TYPE
	SYNTAX PSRectifierEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION "
		An entry (conceptual row) in the rectifierInfoTable."
	INDEX { psRectifierIndex }
	::= { psRectifierTable 1 }

PSRectifierEntry ::= SEQUENCE {
	psRectifierIndex Integer32,
	psRectifierProductNumber DisplayString,
	psRectifierHWVersion DisplayString,
	psRectifierSWVersion DisplayString,
	psRectifierSerialNumber DisplayString,
	psRectifierCurrent Integer32,
	psRectifierIdent DisplayString,
	psRectifierFail StatusChange
	}

psRectifierIndex OBJECT-TYPE
  SYNTAX Integer32(1..16777215)
  MAX-ACCESS read-only
  STATUS current
  DESCRIPTION "Automatically generated index object."
::= { psRectifierEntry 1 }

psRectifierProductNumber OBJECT-TYPE
        SYNTAX DisplayString
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
            "Rectifier Product Number."
::= { psRectifierEntry 2}

psRectifierHWVersion OBJECT-TYPE
        SYNTAX DisplayString
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
            "Rectifier Hardware Revision."
::= { psRectifierEntry 3}

psRectifierSWVersion OBJECT-TYPE
        SYNTAX DisplayString
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
            "Rectifier Software Revision."
::= { psRectifierEntry 4}

psRectifierSerialNumber OBJECT-TYPE
        SYNTAX DisplayString
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
            "Rectifier Serial Number."
::= { psRectifierEntry 5}

psRectifierCurrent OBJECT-TYPE
        SYNTAX Integer32
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
            "Rectifier Current."
::= { psRectifierEntry 6}

psRectifierIdent OBJECT-TYPE
        SYNTAX DisplayString
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
            "Rectifier physical location identifier."
::= { psRectifierEntry 7}

psRectifierFail OBJECT-TYPE
        SYNTAX StatusChange
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION "
	The type of alarm change. One of
	(1) activated
	(2) deactivated"
::= { psRectifierEntry 8}

-- ------------------------------------------------------------------------ 
-- 1.2.12. the Distribution
-- ------------------------------------------------------------------------ 

psDistribution OBJECT IDENTIFIER ::= { system 12 }

psTotalLoadCurrent OBJECT-TYPE
	SYNTAX Integer32
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION "
		Total Load current, stored as integer.
		The integer 2147483647 represents invalid value."
	::= { psDistribution 1 }
    psDistributionLoadTable OBJECT-TYPE
        SYNTAX SEQUENCE OF PSDistributionLoadEntry
        MAX-ACCESS not-accessible
        STATUS current
        DESCRIPTION     
                "Distribution Table."
    ::= { psDistribution 2 }
    
    psDistributionLoadEntry OBJECT-TYPE
        SYNTAX PSDistributionLoadEntry
        MAX-ACCESS not-accessible
        STATUS current
        DESCRIPTION
            "Distribution Measurement Table Entry."
        INDEX { psDistributionLoadIndex }
    ::= { psDistributionLoadTable 1 }

    PSDistributionLoadEntry ::= SEQUENCE {
        psDistributionLoadIndex               Integer32,
        psDistributionLoadCurrent         	  Integer32,
        psDistributionLoadName		  DisplayString	
    }

    psDistributionLoadIndex OBJECT-TYPE
        SYNTAX		  Integer32(1..268386303)
        MAX-ACCESS              not-accessible
        STATUS                  current
        DESCRIPTION
                "Automatically generated index object."
    ::= { psDistributionLoadEntry 1 }

    psDistributionLoadCurrent OBJECT-TYPE
        SYNTAX 		  Integer32
        MAX-ACCESS              read-only
        STATUS                  current
        DESCRIPTION
                "Distribution current in Amps."
    ::= { psDistributionLoadEntry 2 }

    psDistributionLoadName OBJECT-TYPE
        SYNTAX 		  DisplayString
        MAX-ACCESS              read-only
        STATUS                  current
        DESCRIPTION
                "Distribution name."
    ::= { psDistributionLoadEntry 3 }

    psDistributionGeneralTable OBJECT-TYPE
        SYNTAX SEQUENCE OF PSDistributionGeneralEntry
        MAX-ACCESS not-accessible
        STATUS current
        DESCRIPTION     
                "Distribution Table."
    ::= { psDistribution 3 }
    
    psDistributionGeneralEntry OBJECT-TYPE
        SYNTAX PSDistributionGeneralEntry
        MAX-ACCESS not-accessible
        STATUS current
        DESCRIPTION
            "Distribution Measurement Table Entry."
        INDEX { psDistributionGeneralIndex }
    ::= { psDistributionGeneralTable 1 }

    PSDistributionGeneralEntry ::= SEQUENCE {
        psDistributionGeneralIndex               Integer32,
        psDistributionGeneralCurrent         	  Integer32,
        psDistributionGeneralName		  DisplayString	
    }

    psDistributionGeneralIndex OBJECT-TYPE
        SYNTAX		  Integer32(1..268386303)
        MAX-ACCESS              not-accessible
        STATUS                  current
        DESCRIPTION
                "Automatically generated index object."
    ::= { psDistributionGeneralEntry 1 }

    psDistributionGeneralCurrent OBJECT-TYPE
        SYNTAX 		  Integer32
        MAX-ACCESS              read-only
        STATUS                  current
        DESCRIPTION
                "Distribution current in Amps."
    ::= { psDistributionGeneralEntry 2 }

    psDistributionGeneralName OBJECT-TYPE
        SYNTAX 		  DisplayString
        MAX-ACCESS              read-only
        STATUS                  current
        DESCRIPTION
                "Distribution name."
    ::= { psDistributionGeneralEntry 3 }

-- ------------------------------------------------------------------------ 
-- 1.2.13. Converter group
-- ------------------------------------------------------------------------ 

psConverter OBJECT IDENTIFIER ::= { system 13 }

numberOfInstalledConverters OBJECT-TYPE
	SYNTAX Integer32
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION "
		number of converters, stored as integer.
		The integer 2147483647 represents invalid value."
	::= { psConverter 1 }

numberOfConvertersCommunicating OBJECT-TYPE
	SYNTAX Integer32
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION "
		number of converters communicating, stored as integer.
		The integer 2147483647 represents invalid value."
	::= { psConverter 2 }

convertersUsedCapacity OBJECT-TYPE
	SYNTAX Integer32
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION "
		Used capacity, stored as % of the total capacity.
		The integer 2147483647 represents invalid value."
	::= { psConverter 3 }

psConverterVoltage OBJECT-TYPE
	SYNTAX Integer32
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION "
		Converter voltage in mV.
		The integer 2147483647 represents invalid value."
	::= { psConverter 4 }

psTotalConverterCurrent OBJECT-TYPE
	SYNTAX Integer32
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION "
		Total Converter current in Amps.
		The integer 2147483647 represents invalid value."
	::= { psConverter 5 }

psConverterTable OBJECT-TYPE
	SYNTAX SEQUENCE OF PSConverterEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION "
		Table holding information about indivual converters."
	::= { psConverter 6 }

psConverterEntry OBJECT-TYPE
	SYNTAX PSConverterEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION "
		An entry (conceptual row) in the ConverterInfoTable."
	INDEX { psConverterIndex }
	::= { psConverterTable 1 }

PSConverterEntry ::= SEQUENCE {
	psConverterIndex Integer32,
	psConverterProductNumber DisplayString,
	psConverterHWVersion DisplayString,
	psConverterSWVersion DisplayString,
	psConverterSerialNumber DisplayString,
	psConverterCurrent Integer32,
          psConverterIdent DisplayString,
          psConverterFail StatusChange	}

psConverterIndex OBJECT-TYPE
  SYNTAX Integer32(1..100)
  MAX-ACCESS read-only
  STATUS current
  DESCRIPTION "Automatically generated index object."
::= { psConverterEntry 1 }

psConverterProductNumber OBJECT-TYPE
        SYNTAX DisplayString
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
            "Converter Product Number."
::= { psConverterEntry 2}

psConverterHWVersion OBJECT-TYPE
        SYNTAX DisplayString
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
            "Converter Hardware Revision."
::= { psConverterEntry 3}

psConverterSWVersion OBJECT-TYPE
        SYNTAX DisplayString
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
            "Converter Software Revision."
::= { psConverterEntry 4}

psConverterSerialNumber OBJECT-TYPE
        SYNTAX DisplayString
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
            "Converter Serial Number."
::= { psConverterEntry 5}

psConverterCurrent OBJECT-TYPE
        SYNTAX Integer32
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
            "Converter Current."
::= { psConverterEntry 6}

psConverterIdent OBJECT-TYPE
        SYNTAX DisplayString
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
            "Converter physical location identifier."
::= { psConverterEntry 7}

psConverterFail OBJECT-TYPE
        SYNTAX StatusChange
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION "
	The type of alarm change. One of
	(1) activated
	(2) deactivated"
::= { psConverterEntry 8}

-- ------------------------------------------------------------------------ 
-- 1.2.14. Control group
-- ------------------------------------------------------------------------ 

psControl OBJECT IDENTIFIER ::= { system 14 }

controlBatteryTest OBJECT-TYPE
	SYNTAX Integer32
	MAX-ACCESS read-write
	STATUS current
	DESCRIPTION "
		Control battery test, start(1), stop (0)."
	::= { psControl 1 }

controlRelay8 OBJECT-TYPE
	SYNTAX Integer32
	MAX-ACCESS read-write
	STATUS current
	DESCRIPTION "
		Control relay8, close(1), open(0)."
	::= { psControl 2 }

controlRelay7 OBJECT-TYPE
	SYNTAX Integer32
	MAX-ACCESS read-write
	STATUS current
	DESCRIPTION "
		Control relay7, close(1), open(0)."
	::= { psControl 3 }

controlRelay6 OBJECT-TYPE
	SYNTAX Integer32
	MAX-ACCESS read-write
	STATUS current
	DESCRIPTION "
		Control relay6, close(1), open(0)."
	::= { psControl 4 }

controlRelayTest OBJECT-TYPE
	SYNTAX Integer32
	MAX-ACCESS read-write
	STATUS current
	DESCRIPTION "
		Control Relay test, start(1), stop (0)."
	::= { psControl 5 }


-- ------------------------------------------------------------------------ 
-- 1.2.15. EquipmentSignalTable
-- ------------------------------------------------------------------------ 

psEquipmentSignalTable OBJECT-TYPE
	SYNTAX SEQUENCE OF EquipmentSignalTableEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION "
		Table of indexed equipment signal values."
	::= { system 15 }

equipmentSignalTableEntry OBJECT-TYPE
	SYNTAX EquipmentSignalTableEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION "
		An entry (conceptual row) in the psEquipment Signal Table."
	INDEX { psEquipmentSignalTableEntryIndex }
	::= { psEquipmentSignalTable 1 }

EquipmentSignalTableEntry ::= SEQUENCE {
	psEquipmentSignalTableEntryIndex Integer32,
	psEquipmentSignalValue Integer32 }

psEquipmentSignalTableEntryIndex OBJECT-TYPE
	SYNTAX Integer32(1..268386303)
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION "
		The unique sequence number of this equipment signal."
	::= { equipmentSignalTableEntry 1 }

psEquipmentSignalValue OBJECT-TYPE
	SYNTAX Integer32
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION "
		Indexed equipment signal value."
	::= { equipmentSignalTableEntry 2 }

------------------------------------------------------------
-- Alarm trap counter { powerMIB 3 }
------------------------------------------------------------

alarmLastTrapNo OBJECT-TYPE
	SYNTAX Counter32
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION "
		The sequence number of last submitted alarm trap,
		also last row in alarmTrapTable."
	::= { powerMIB 3 }

------------------------------------------------------------
-- Active Alarm table { powerMIB 4 }
------------------------------------------------------------

alarmActiveAlarmTable OBJECT-TYPE
	SYNTAX SEQUENCE OF ActiveAlarmEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION "
		Table holding information about the currently active alarms."
	::= { powerMIB 4 }

activeAlarmEntry OBJECT-TYPE
	SYNTAX ActiveAlarmEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION "
		An entry (conceptual row) in the alarmTrapTable."
	INDEX { alarmIndex }
	::= { alarmActiveAlarmTable 1 }

ActiveAlarmEntry ::= SEQUENCE {
	alarmIndex Counter32,
	alarmTime DateAndTime,
	alarmStatusChange StatusChange,
	alarmSeverity Status,
	alarmDescription DisplayString,
	alarmType Integer32 }

alarmIndex OBJECT-TYPE
	SYNTAX Counter32
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION "
		The unique sequence number of this alarm trap."
	::= { activeAlarmEntry 1 }

alarmTime OBJECT-TYPE
	SYNTAX DateAndTime
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION "
		Date and time when event occured (local time), including
		timezone if supported by controller."
	::= { activeAlarmEntry 2 }

alarmStatusChange OBJECT-TYPE
	SYNTAX StatusChange
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION "
		The type of alarm change. One of
		(1) activated
		(2) deactivated"
	::= { activeAlarmEntry 3 }

alarmSeverity OBJECT-TYPE
	SYNTAX Status
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION "
		The severity of the alarm. One of
		(3) warning - OA, lowest level of alarm severity
		(4) minor - A3
		(5) major - MA
		(6) critical - CA, highest level of alarm severity"
	::= { activeAlarmEntry 4 }

alarmDescription OBJECT-TYPE
	SYNTAX DisplayString
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION "
		Free-text description of alarm."
	::= { activeAlarmEntry 5 }

alarmType OBJECT-TYPE
	SYNTAX Integer32
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION "
		Alarm type, i.e. an integer specifying the type of alarm."
	::= { activeAlarmEntry 6 }

------------------------------------------------------------
-- Events/traps { powerMIB 5 }
------------------------------------------------------------

powerEvents OBJECT IDENTIFIER ::= { powerMIB 5 }

alarmTrap NOTIFICATION-TYPE
	OBJECTS {
		alarmIndex,
		alarmTime,
		alarmStatusChange,
		alarmSeverity,
		alarmDescription,
		alarmType }
	STATUS current
	DESCRIPTION "
		An alarm trap is sent when an alarm occurs (activated) or
		returns to normal state (deactivated). Alarm traps are logged
		in alarmTrapTable. Variables in this trap:
		* alarmIndex - The unique sequence number of this alarm trap.
		* alarmTime - Date and time when event occured (local time),
		      including timezone if supported by controller.
		* alarmStatusChange - (1) activated or (2) deactivated.
		* alarmSeverity - Integer describing the severity of the alarm.
		* alarmDescription - Free-text description of alarm.
		* alarmType - Integer indicating type of alarm."
	::= { powerEvents 1 }

alarmActiveTrap NOTIFICATION-TYPE
	OBJECTS {
		alarmTime,
		alarmSeverity,
		alarmDescription,
		alarmType }
	STATUS current
	DESCRIPTION "
		An alarm trap is sent when an alarm occurs (activated)
		Variables in this trap
		* alarmTime - Date and time when event occured (local time),
		      including timezone if supported by controller.
		* alarmSeverity - Integer describing the severity of the alarm.
		* alarmDescription - Free-text description of alarm.
		* alarmType - Integer indicating type of alarm."
	::= { powerEvents 2 }

alarmCeaseTrap NOTIFICATION-TYPE
	OBJECTS {
		alarmTime,
		alarmSeverity,
		alarmDescription,
		alarmType }
	STATUS current
	DESCRIPTION "
		An alarm trap is sent when an alarm returns to normal state (clear, deactivated). 
                Variables in this trap:
		* alarmTime - Date and time when event occured (local time),
		      including timezone if supported by controller.
		* alarmSeverity - Integer describing the severity of the alarm.
		* alarmDescription - Free-text description of alarm.
		* alarmType - Integer indicating type of alarm."
	::= { powerEvents 3 }

------------------------------------------------------------
-- End of MIB definitions
------------------------------------------------------------

END