--MibName=raisecomOpticalMonitorMIB
-- *****************************************************************
-- RAISECOM-OPTICAL-TRANSCEIVER-MIB.my
--
-- Copyright(c) 2003-2005 by RAISECOM TECH, Ltd. 
-- All rights reserved.
-- *****************************************************************       

-- *****************************************************************
-- Modi ReportFormat: <number>, <time>, <author>, <desc> 
-- 01, 20110623, yangzhognhong, change the value of the node raisecomOpticalTransceiverMediaType 
--                              for SFP+ development
--
-- *****************************************************************


RAISECOM-OPTICAL-TRANSCEIVER-MIB DEFINITIONS ::= BEGIN

IMPORTS
    Integer32, Unsigned32,
    MODULE-IDENTITY,
    NOTIFICATION-TYPE,
    OBJECT-TYPE,
    TimeTicks                       	FROM SNMPv2-SMI
		raisecomAgent    
					FROM RAISECOM-BASE-MIB
    TEXTUAL-CONVENTION                  FROM SNMPv2-TC
    MODULE-COMPLIANCE,
    NOTIFICATION-GROUP,
    OBJECT-GROUP                        FROM SNMPv2-CONF
    ifIndex                             FROM IF-MIB   
    raisecomNotificationLocation        FROM RAISECOM-COMMON-MANAGEMENT-MIB
    ClearVar                            FROM SWITCH-TC;

raisecomOpticalTransceiver MODULE-IDENTITY
    LAST-UPDATED   "201005190000Z"
    ORGANIZATION   "Raisecom, Inc."
    CONTACT-INFO  
                "       Raise Systems
                        
                Postal: Beijing,
                        China

                   Tel: 86-010-82884499

                E-mail: chenyu@raisecom.com"
    DESCRIPTION
        "This MIB module defines objects to monitor optical
        characteristics on the optical interfaces in a network element. "
        REVISION   "201005190000Z"
        DESCRIPTION
            "The initial revision of this MIB."
        ::={ raisecomAgent 18 }


-- Textual Conventions
EnableVar ::= TEXTUAL-CONVENTION                                
    STATUS      current
    DESCRIPTION
        "enable or disable a function."
    SYNTAX    INTEGER {
                       enable(1),
                       disable(2)
                      } 
     	
OpticalParameterType ::= TEXTUAL-CONVENTION
    STATUS    current
    DESCRIPTION
        "This value indicates the optical parameter that is
        being monitored. Valid values are -OpticalParameterType 

        transceiverTemperature(1)   		:transceiver temperature
        txbiasCurrent(2)         		:TX bias current
        txPower(3)       			:TX output power
        rxPower(4)       			:RX received optical power
        laserTemperature(5)     		:laser temperature
        p5V0supplyVoltage(6)     		:+5V supply voltage
        p3V3supplyVoltage(7)    		:+3.3V supply voltage
        p1V8supplyVoltage(8)     		:+1.8V supply voltage
        n5V2supplyVoltage(9)    		:-5.2V supply voltage
        apdBiasVoltage(10)    		:APD bias voltage
        p5V0supplyCurrent(11)     		:+5V supply currnet
        p3V3supplyCurrent(12)    		:+3.3V supply currnet
        p1V8supplyCurrent(13)     		:+1.8V supply currnet
        n5V2supplyCurrent(14)     		:-5.2V supply currnet
        tecCurrent(15)          		:TEC currnet
        laserWavelength(16)      		:laser wavelength

       " 
        
    SYNTAX    INTEGER {
			        transceiverTemperature (1),   
        			txbiasCurrent (2),          
        			txPower (3),       
       			    rxPower (4),       
        			laserTemperature(5),     
        			p5V0supplyVoltage(6),     
        			p3V3supplyVoltage(7),    
        			p1V8supplyVoltage(8),     
        			n5V2supplyVoltage(9),     
        			apdBiasVoltage(10),     
        			p5V0supplyCurrent(11),     
        			p3V3supplyCurrent(12),    
        			p1V8supplyCurrent(13),     
        			n5V2supplyCurrent(14),    
        			tecCurrent(15),          
       			    laserWavelength(16)
   
              }


OpticalParameterValue ::= TEXTUAL-CONVENTION
    STATUS    current
    DESCRIPTION
        "The value of the optical parameter that is being monitored.
              The range of values varies depending on the type of optical  parameter being monitored,
        as identified by a corresponding object with syntax OpticalParameterType.
              When the optical parameter being monitored is 'XXTemperature',the supported range 
        is from -40000 to 125000, in units of  1/1000 degrees centigrade.
        Example: A value of 23500 represents a temperature reading of 23.5 degrees C.
        The temperature is shown in unit of degrees centigrade, and the precision is 0.1.        
              When the optical parameter being monitored is 'txbiasCurrent',the supported range
        is from 0 to 131000, in units of 1/1000 mA.
        Example: A value of 1000 represents a TX bias current reading of 1.0mA. 
        The 'txbiasCurrent'is shown in unit of mA, and the precision is 0.1.
              When the optical parameter being monitored is 'txPower',the supported range
       is from -40000 to 8200, in units of 1/1000 dbm.
        Example: A value of 77800 represents a TX output power reading of 7.78 dBm.
        The 'txPower' is shown in unit of dBm, and the precision is 0.1.
              When the optical parameter being monitored is 'rxPower',the supported range
        is from -40000 to 8200, in units of 1/1000 dbm.
        Example: A value of 7780 represents a RX received optical power reading of 7.78 dBm. 
        The 'rxPower' is shown in unit of dBm, and the precision is 0.1.
              When the optical parameter being monitored is 'XXsupplyVoltage',the supported range
        is from 0 to 6550, in units of 1/1000 V. 
		Example: A value of 6000 represents a XX supply Voltage eading of 6.00V.
		The 'XXsupplyVoltage'is shown in unit of V, and the precision is 0.01.
              When the optical parameter being monitored is 'apdBiasVoltage,the supported range
        is from 0 to 655300 , in units of 1/1000 V . 
		Example: A value of 600000 represents a APD BiasVoltage reading of 600.0V.
		The 'apdBiasVoltage' is shown in unit of V, and the precision is 0.1.
              When the optical parameter being monitored is 'XXsupplyCurrent',the supported range
        is from 0 to 6553600, in units of 1/1000 mA . 
        Example: A value of 6000000 represents a XX supply current reading of 6000.0mA. 
        The 'XXsupplyCurrent' is shown in unit of mA, and the precision is 0.1.
              When the optical parameter being monitored is 'tecCurrent',the supported range
        is from 0 to 6553600, in units of 1/1000 mA . 
        Example: A value of 6000000 represents a TEC Current reading of 6000.0mA.
        The 'tecCurrent' is shown in unit of mA, and the precision is 0.1.
              When the optical parameter being monitored is 'laserWavelength,the supported range
        is from 0 to 3276750, in units of 1/1000 nm . 
        Example: A value of 3000000 represents a laser wavelength reading of 3000.0nm.
        The 'laserWavelength'is shown in unit of nm, and the precision is 0.01.
      "
    SYNTAX    Integer32 (-1000000 | -40000..6553600)

OpticalPMPeriod ::= TEXTUAL-CONVENTION
    STATUS      current
    DESCRIPTION
        "This value indicates the time period over which performance
        monitoring data has been collected."
    SYNTAX      INTEGER {
                    fifteenMin(1),
                    twentyFourHour(2)
                } 
                
-- MIB Global Enable Definitions

raisecomOpticalTransceiverGlobalEnable       OBJECT IDENTIFIER ::=
                                        {raisecomOpticalTransceiver 1 }   
                                        
raisecomOpticalTransceiverNotifyEnable OBJECT-TYPE
    SYNTAX      EnableVar
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "This object specifies the generation of device notifications,
         enable or disable.  
         
         this object belongs to xfp and sfp.
        "
    DEFVAL { disable }
    ::={ raisecomOpticalTransceiverGlobalEnable 1 }

raisecomOpticalTransceiverDDMEnable OBJECT-TYPE
    SYNTAX      EnableVar
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "Enable or disable digitaldiagnotic on the device.
        
        this object belongs to xfp and sfp.
        "
    DEFVAL { disable}
    ::={ raisecomOpticalTransceiverGlobalEnable 2 }

raisecomOpticalTransceiverCheckPwdEnable OBJECT-TYPE
    SYNTAX      EnableVar
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "This object specifies the status of password checking on the device,
         enable or disable. 
         
         this object belongs to xfp.
        "
    DEFVAL { disable}
    ::={ raisecomOpticalTransceiverGlobalEnable 3 }

raisecomOpticalTransceiverPollInterval OBJECT-TYPE
    SYNTAX  INTEGER
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "This object specifies the value of poll-interval on the device.
        
        this object belongs to xfp and sfp.
        "
    ::={ raisecomOpticalTransceiverGlobalEnable 4 }
    
-- MIB Object Definitions

raisecomOpticalTransceiverObjects        OBJECT IDENTIFIER ::=
                                        {raisecomOpticalTransceiver 2 }

-- groups in this MIB module   
raisecomOpticalTransceiverInfoGroup               OBJECT IDENTIFIER ::=
                                        {raisecomOpticalTransceiverObjects 1 }

raisecomOpticalTransceiverDDMGroup                OBJECT IDENTIFIER ::=
                                        {raisecomOpticalTransceiverObjects 2 }

raisecomOpticalTransceiverPMGroup                 OBJECT IDENTIFIER ::=
                                        {raisecomOpticalTransceiverObjects 3 }  
                                        
raisecomOpticalTransceiverStatusGroup             OBJECT IDENTIFIER ::=
                                        {raisecomOpticalTransceiverObjects 4 }

-- raisecomOpticalTransceiverInfoTable

raisecomOpticalTransceiverInfoTable OBJECT-TYPE
        SYNTAX SEQUENCE OF RaisecomOpticalTransceiverInfoEntry
        MAX-ACCESS not-accessible
        STATUS current
        DESCRIPTION
            "Trancetver information Table."
        ::= { raisecomOpticalTransceiverInfoGroup 1 }

raisecomOpticalTransceiverInfoEntry OBJECT-TYPE
    SYNTAX      RaisecomOpticalTransceiverInfoEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "An entry in the raisecomOpticalTransceiverInfoTable."
    INDEX        { ifIndex }
    ::={ raisecomOpticalTransceiverInfoTable 1 }


RaisecomOpticalTransceiverInfoEntry ::= SEQUENCE {
	raisecomOpticalTransceiverType        INTEGER,
	raisecomOpticalTransceiverConnectorType       INTEGER,
	raisecomOpticalTransceiverVendorName  OCTET STRING,
	raisecomOpticalTransceiverVendorPN    OCTET STRING,
	raisecomOpticalTransceiverVendorSN    OCTET STRING,
	raisecomOpticalTransceiverMediaType INTEGER,
	raisecomOpticalTransceiverTransmissionDistance  Integer32,  
	raisecomOpticalTransceiverAbility        Unsigned32,
	raisecomOpticalTransceiverDDM     INTEGER,
	raisecomOpticalTransceiverCalibrationType   INTEGER,
	raisecomOpticalTransceiverRSSI       INTEGER,
	raisecomOpticalTransceiverVendorRev   OCTET STRING,
	raisecomOpticalTransceiverBRMax       INTEGER,
	raisecomOpticalTransceiverBRMin       INTEGER,
	raisecomOpticalTransceiverWavelengthContrl   INTEGER,	 
	raisecomOpticalTransceiverWavelength  Integer32,
	raisecomOpticalTransceiverWaveTolerance   OCTET STRING,
	raisecomOpticalTransceiverCompatibility   OCTET STRING,
	raisecomOpticalTransceiverPowerDissipation   INTEGER,
	raisecomOpticalTransceiverCDR                INTEGER,
	raisecomOpticalTransceiverRefClock           INTEGER,
	raisecomOpticalTransceiverTransmitterType    INTEGER,
	raisecomOpticalTransceiverCooled	         INTEGER,
	raisecomOpticalTransceiverTunalbe            INTEGER,
	raisecomOpticalTransceiverDetectorType       INTEGER,
	raisecomOpticalTransceiverLineLoopBack       INTEGER,
	raisecomOpticalTransceiverXFILoopBack        INTEGER,
	raisecomOpticalTransceiverVps                INTEGER,
	raisecomOpticalTransceiverTxDis              INTEGER,
	raisecomOpticalTransceiverStandby              INTEGER,
	raisecomOpticalTransceiverInVpsLowPower      INTEGER,
	raisecomOpticalTransceiverOutVpsLowPower     INTEGER,
	raisecomOpticalTransceiverFEC                INTEGER,
	raisecomOpticalTransceiverCMU                INTEGER,
	raisecomOpticalTransceiverBR                 INTEGER

}

raisecomOpticalTransceiverType OBJECT-TYPE
		SYNTAX  INTEGER{ 
						unknown(1),
	 			        gbic(2),
	       			    soldered(3),
						sfp(4),
						xbi(5),
						xenpak(6),
						xfp(7),
						xff(8),
						xfp_e(9),
						xpak(10),
						x2(11),
						sfpj(12)						
	       			   }
		ACCESS	read-only
		STATUS	current
		DESCRIPTION
			"This object specifies the physical type of the transceiver, 
			such as xfp or sfp , and so on.
			
			this object belongs to xfp and sfp.
			"
		::= { raisecomOpticalTransceiverInfoEntry 1 }
		
raisecomOpticalTransceiverConnectorType OBJECT-TYPE
		SYNTAX  INTEGER
		{
 			unknown(0),
       		sc (1),
			db9(2),
			hssdc(3),
			bnc_tnc(4),
			fiber_coaxial_head(5),
			fiber_jack(6),
			lc(7),
			mt_rj(8),
			mu(9),
			sg(10),
			fiber_pigtail(11),
			mpo_parallel_optic(12),
			hssdcII (20),
			copper (21),
			rj45 (22)
       	}
		ACCESS	read-only
		STATUS	current
		DESCRIPTION
			"This object specifies the connector type of the transceiver
             unknown, sc, db9, hssdc, bnc_tnc, fiber_coaxial_head, fiber_outlet, 
             lc, mt_rj, mu, sg, fiber_pigtail, mpo_parallel_optic , hssdcII, 
             copper, rj45. 
             
             this object belongs to xfp and sfp.
			"
		::= { raisecomOpticalTransceiverInfoEntry 2 }
				
raisecomOpticalTransceiverVendorName OBJECT-TYPE
		SYNTAX	OCTET STRING
		ACCESS	read-only
		STATUS	current
		DESCRIPTION
			"Vendor name of the interface.
			
			 this object belongs to xfp and sfp.
			"
		::= { raisecomOpticalTransceiverInfoEntry 3 }
		
raisecomOpticalTransceiverVendorPN OBJECT-TYPE
		SYNTAX	OCTET STRING
		ACCESS	read-only
		STATUS	current
		DESCRIPTION
			"Vendor part number of the interface.
			
			this object belongs to xfp and sfp.
			"
		::= { raisecomOpticalTransceiverInfoEntry 4 }
		
raisecomOpticalTransceiverVendorSN OBJECT-TYPE
		SYNTAX	OCTET STRING
		ACCESS	read-only
		STATUS	current
		DESCRIPTION
			"Vendor serial number of the interface.
			
			this object belongs to xfp and sfp.
			"
		::= { raisecomOpticalTransceiverInfoEntry 5 }
		
raisecomOpticalTransceiverMediaType OBJECT-TYPE
		SYNTAX INTEGER
       {
            single_mode(1),
            multi_modeE50(2),
            multi_mode50(3),
            multi_mode625(4),
            copper(5),
            single_modeKm(6), 
            multi_modeOM3(7)                 
        }
		ACCESS	read-only
		STATUS	current
		DESCRIPTION
			"Types of the fiber, 
            single_mode, multi_modeE50, multi_mode50,multi_mode625,copper.
            single_modeKm,multi_modeOM3
            
            this object belongs to xfp and sfp.
			"
		::= { raisecomOpticalTransceiverInfoEntry 6 }
		
raisecomOpticalTransceiverTransmissionDistance OBJECT-TYPE
		SYNTAX	Integer32
		ACCESS	read-only
		STATUS	current
		DESCRIPTION
			"The max distance which the interface could transmit,
             measured in meter.
             The object will be shown in unit of Km, and the precision is 0.001.
             
             this object belongs to xfp and sfp.
            "
		::= { raisecomOpticalTransceiverInfoEntry 7 }		

raisecomOpticalTransceiverAbility  OBJECT-TYPE
		SYNTAX	Unsigned32
		ACCESS	read-only
		STATUS	current
		DESCRIPTION
			"This object specifies the ability of optical module digitaldiagnotic
			 funtion. Currently, the digitaldiagnotic objects of our optical module 
			 inculde 16 parameters.   
			 
			 this object has 32 bits, each bit represents a digital diagnotic parameter.
			 if the bit value is 0, it means that the optical module does not provide 
			 digital diagnotic funtion for relative parameter.if the bit value is 1,it 
			 means that the optical module provides digital diagnotic funtion for
			 relative parameter.
			 
			 this object belongs to xfp and sfp.
			 
			 The relation between parameters and bits is following: 
			3216 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1:
			The relation between parameters and bits is following: 
			3216 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1:
			| 1bit           | 2bit           | 3bit             | 4bit           
			| APDƫõѹ    | 0      | TEC        | ¶

			| 5bit           | 6bit          |7bit             | 8bit
			|      | +5Vѹ   | +3.3Vѹ  | +1.8Vѹ

			| 9bit           | 10bit         |11bit             | 12bit
			| -5.2Vѹ  | +5V   | 0ޣ          | 0ޣ

			| 13bit           | 14bit         | 15bit            | 16bit 
			| +3.3V   | +1.8V | -5.2V   | ģ¶

			| 17bit           | 18bit         | 19bit            | 20bit ~ 32bit 
			| ƫõ  | ͹⹦    |չ⹦       |  0

            But when the optical module is sfp, the 6 bit will represents 
            the supplyVoltage of sfp.
            "
		::= { raisecomOpticalTransceiverInfoEntry 8 }		      
		
raisecomOpticalTransceiverDDM     OBJECT-TYPE
		SYNTAX  INTEGER{
	 			        support(1),
	       			    notsupport(2)
	       			   }
		ACCESS	read-only
		STATUS	current
		DESCRIPTION
			"This object specifies if the transceiver supports on digital diagnostic function, 
			support or not support.To the xfp, the default value of this object is support.
			
			this object belongs to xfp and sfp.
			"
		::= { raisecomOpticalTransceiverInfoEntry 9 }
		
raisecomOpticalTransceiverCalibrationType   OBJECT-TYPE
		SYNTAX  INTEGER{ 
						unknown(1),
	 			        internal(2),
	       			    external(3)
	      			   }
		ACCESS	read-only
		STATUS	current
		DESCRIPTION
			"This object specifies the calibration type of the transceiver, 
			internal, external, unknown.
			
			this object belongs to xfp and sfp.
			"
		::= { raisecomOpticalTransceiverInfoEntry 10 }
		
raisecomOpticalTransceiverRSSI   OBJECT-TYPE
		SYNTAX  INTEGER{
	 			        support(1),
	       			    notsupport(2)
	       			   }
		ACCESS	read-only
		STATUS	current
		DESCRIPTION
			"This object specifies the calibration type of the transceiver, 
			support or not support.
			
			this object belongs to xfp and sfp.
			"
		::= { raisecomOpticalTransceiverInfoEntry 11 }
 
raisecomOpticalTransceiverVendorRev    OBJECT-TYPE
		SYNTAX	OCTET STRING
		ACCESS	read-only
		STATUS	current
		DESCRIPTION
			" the version number of the transceiver.
			 this object belongs to xfp and sfp.
			"
		::= { raisecomOpticalTransceiverInfoEntry 12 }   

raisecomOpticalTransceiverBRMax      OBJECT-TYPE
		SYNTAX	INTEGER
		ACCESS	read-only
		STATUS	current
		DESCRIPTION
			" the min data rate of the transceiver,mesured in Mbps .
			  this object belongs to xfp and sfp.

			The object will be shown in unit of Gbps, and the precision is 0.1.
			"
		::= { raisecomOpticalTransceiverInfoEntry 13 } 
		
raisecomOpticalTransceiverBRMin       OBJECT-TYPE
		SYNTAX	INTEGER
		ACCESS	read-only
		STATUS	current
		DESCRIPTION
			" the min data rate of the transceiver,mesured in Mbps.
			
			  this object belongs to xfp and sfp.To the sfp, 
			  the min data rate value is equal to the max data rate value. 
			  
			  The object will be shown in unit of Gbps, and the precision is 0.1.
			 "
		::= { raisecomOpticalTransceiverInfoEntry 14 }  

raisecomOpticalTransceiverWavelengthContrl   OBJECT-TYPE
		SYNTAX	INTEGER
		{
	       support(1),
     	   notsupport (2)
        }
		ACCESS	read-only
		STATUS	current
		DESCRIPTION
			"if the transceiver supports on wavelength control
			support,notsupport.
			this object belongs to xfp.
			"
		::= { raisecomOpticalTransceiverInfoEntry 15 }

raisecomOpticalTransceiverWavelength OBJECT-TYPE
		SYNTAX	Integer32
		ACCESS	read-only
		STATUS	current
		DESCRIPTION
			"Wavelength of the interface, measured in pm(0.001nm).
			 this object belongs to xfp.
			 The object will be shown in unit of nm, and the precision is 0.01.
			"
		::= { raisecomOpticalTransceiverInfoEntry 16 }

raisecomOpticalTransceiverWaveTolerance   OBJECT-TYPE
		SYNTAX	OCTET STRING
		ACCESS	read-only
		STATUS	current
		DESCRIPTION
			"the range of laser wavelength from nominal wavelength,mesured in pm(0.001*nm).
			 this object belongs to xfp.
			 The object will be shown in unit of nm, and the precision is 0.01.
			"
		::= { raisecomOpticalTransceiverInfoEntry 17 }    

raisecomOpticalTransceiverCompatibility   OBJECT-TYPE
		SYNTAX	OCTET STRING
		ACCESS	read-only
		STATUS	current
		DESCRIPTION
			"the compatibility type that the transceiver supports,such as 10GBASE-SR.
			this object belongs to xfp.
			"
		::= { raisecomOpticalTransceiverInfoEntry 18 } 

raisecomOpticalTransceiverPowerDissipation   OBJECT-TYPE
		SYNTAX	INTEGER
		{
 			p1W5(1),
       		p2W5(2),
			p3W5(3),
			exceed(4)
       	}
		ACCESS	read-only
		STATUS	current
		DESCRIPTION
			"the max power dissipation of the transceiver, 
			p1W5,p2W5,p3W5,exceed3W5.
			this object belongs to xfp.
			"
		::= { raisecomOpticalTransceiverInfoEntry 19 } 

raisecomOpticalTransceiverCDR             OBJECT-TYPE
		SYNTAX	INTEGER
		{
 		   support(1),
           notsupport(2)
        }
		ACCESS	read-only
		STATUS	current
		DESCRIPTION
			"the optical module supports on CDR fundtion.
			support,notsupport.
			this object belongs to xfp.
			"
		::= { raisecomOpticalTransceiverInfoEntry 20 } 

raisecomOpticalTransceiverRefClock           OBJECT-TYPE
		SYNTAX	INTEGER
		{
 	       required(1),
     	   notrequired (2)
        }
		ACCESS	read-only
		STATUS	current
		DESCRIPTION
			" if the transceiver requires outside reference clock
			required,notrequired.
			this object belongs to xfp.
			"
		::= { raisecomOpticalTransceiverInfoEntry 21 }
		
raisecomOpticalTransceiverTransmitterType     OBJECT-TYPE
		SYNTAX  INTEGER
		{
			vcsel850nm(1),
			vcsel1310nm(2),
			vcsel1550nm(3),
			fp1310nm(4),
			dfb1310nm(5),
			dfb1550nm(6),
			eml1310nm(7),
			eml1550nm(8),
			copper_others(9)
       }

		ACCESS	read-only
		STATUS	current
		DESCRIPTION
			"The transmitter type of the transceiver,such as 850 nm VCSEL.
			this object belongs to xfp.
			"
		::= { raisecomOpticalTransceiverInfoEntry 22 }
		
raisecomOpticalTransceiverCooled	         OBJECT-TYPE
		SYNTAX	INTEGER
		{
 	       cooled(1),
     	   uncooled (2)
        }
		ACCESS	read-only
		STATUS	current
		DESCRIPTION
			"The transmitter cooled type of the transceiver
			 cooled,uncooled.
			 this object belongs to xfp.
			 "
		::= { raisecomOpticalTransceiverInfoEntry 24 }
		
raisecomOpticalTransceiverTunalbe            OBJECT-TYPE
		SYNTAX	INTEGER
		{
 	       tunable (1),
    	   untunable (2)
        }
		ACCESS	read-only
		STATUS	current
		DESCRIPTION
			"The transmitter tunable type of the transceiver
			tunable,untunable.
			this object belongs to xfp.
			"
		::= { raisecomOpticalTransceiverInfoEntry 25 }
		
raisecomOpticalTransceiverDetectorType       OBJECT-TYPE
		SYNTAX	INTEGER
		{
	       pin(1),
		   apd(2)
	    }
		ACCESS	read-only
		STATUS	current
		DESCRIPTION
			"The detector type of the transceiver
			 pin, apd.
			 this object belongs to xfp.
			 "
		::= { raisecomOpticalTransceiverInfoEntry 26 }
		
raisecomOpticalTransceiverLineLoopBack       OBJECT-TYPE
		SYNTAX	INTEGER
		{
 			support(1),
       		notsupport(2)
       	}
		ACCESS	read-only
		STATUS	current
		DESCRIPTION
			"The transceiver support status of sideline loop-back control
			support,notsupport.
			this object belongs to xfp.
			"
		::= { raisecomOpticalTransceiverInfoEntry 27 }
		
raisecomOpticalTransceiverXFILoopBack        OBJECT-TYPE
		SYNTAX	INTEGER
		{
 			support(1),
       		notsupport(2)
       	}
		ACCESS	read-only
		STATUS	current
		DESCRIPTION
			"The transceiver support status of XFI loop-back control
			support,notsupport.
			this object belongs to xfp.
			"
		::= { raisecomOpticalTransceiverInfoEntry 28 }
		
raisecomOpticalTransceiverVps                OBJECT-TYPE
		SYNTAX	INTEGER
		{
 			support(1),
       		notsupport(2)
       	}
		ACCESS	read-only
		STATUS	current
		DESCRIPTION
			"This object specifies if the optical module supports on VPS
			support,notsupport.
			this object belongs to xfp.
			"
		::= { raisecomOpticalTransceiverInfoEntry 29 }
		
raisecomOpticalTransceiverTxDis              OBJECT-TYPE
		SYNTAX	INTEGER
		{
 			support(1),
       		notsupport(2)
       	}
		ACCESS	read-only
		STATUS	current
		DESCRIPTION
			"The transceiver support status of software control the transmitter status
			support,notsupport.
			this object belongs to xfp.
			"
		::= { raisecomOpticalTransceiverInfoEntry 30 }
		
raisecomOpticalTransceiverStandby              OBJECT-TYPE
		SYNTAX	INTEGER
		{
 			support(1),
       		notsupport(2)
       	}
		ACCESS	read-only
		STATUS	current
		DESCRIPTION
			"The transceiver support status of software control the standby mode.
			support,notsupport.
			this object belongs to xfp.
			"
		::= { raisecomOpticalTransceiverInfoEntry 31 }
		
raisecomOpticalTransceiverInVpsLowPower      OBJECT-TYPE
		SYNTAX	INTEGER
		{
 			support(1),
       		notsupport(2)
       	}
		ACCESS	read-only
		STATUS	current
		DESCRIPTION
			"The VPS in low power support status of the transceiver
			support,notsupport.
			this object belongs to xfp.
			"
		::= { raisecomOpticalTransceiverInfoEntry 32 }
		
raisecomOpticalTransceiverOutVpsLowPower     OBJECT-TYPE
		SYNTAX	INTEGER
		{
 			support(1),
       		notsupport(2)
       	}
		ACCESS	read-only
		STATUS	current
		DESCRIPTION
			"The VPS out low power support status of the transceiver
			support,notsupport.
			this object belongs to xfp.
			"
		::= { raisecomOpticalTransceiverInfoEntry 33 }
		
raisecomOpticalTransceiverFEC                OBJECT-TYPE
		SYNTAX	INTEGER
		{
 			support(1),
       		notsupport(2)
       	}
		ACCESS	read-only
		STATUS	current
		DESCRIPTION
			"The FEC support status of transceiver
			support,notsupport.
			this object belongs to xfp.
			"
		::= { raisecomOpticalTransceiverInfoEntry 34 }
		
raisecomOpticalTransceiverCMU                OBJECT-TYPE
		SYNTAX	INTEGER
		{
 			support(1),
       		notsupport(2)
       	}
		ACCESS	read-only
		STATUS	current
		DESCRIPTION
			"The CMU support status of transceiver
			support,notsupport.
			this object belongs to xfp.
			"
		::= { raisecomOpticalTransceiverInfoEntry 35 }
		
raisecomOpticalTransceiverBR OBJECT-TYPE
		SYNTAX  INTEGER
		{
 			unknown(0),
 			bitrate-125Mbps(1),
       		bitrate-155Mbps (2),
			bitrate-622Mbps(6),
			bitrate-1DOT25Gbps(13),
			bitrate-2DOT5Gbps(19)
       	}
		ACCESS	read-only
		STATUS	current
		DESCRIPTION
			"This object specifies the Nominal bitrate of the transceiver
             125Mbps, 155Mbps, 622Mbps, 1.25Gbps, 2.5Gbps. 
             
             this object belongs to xfp and sfp.
			"
		::= { raisecomOpticalTransceiverInfoEntry 36 }
		
-- raisecomOpticalDDMTable

raisecomOpticalTransceiverDDMTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF RaisecomOpticalTransceiverDDMEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "This table provides objects to monitor optical
        parameters in a network element. "
    ::={ raisecomOpticalTransceiverDDMGroup 1 }

raisecomOpticalTransceiverDDMEntry OBJECT-TYPE
    SYNTAX      RaisecomOpticalTransceiverDDMEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "An entry in the raisecomOpticalTransceiverMonTable provides objects to
        monitor an optical parameter at an optical interface.
        "
    INDEX        { 	ifIndex, 
		raisecomOpticalTransceiverParameterType
	}
    ::={ raisecomOpticalTransceiverDDMTable 1 }
                         
RaisecomOpticalTransceiverDDMEntry ::= SEQUENCE {
    raisecomOpticalTransceiverParameterType            OpticalParameterType,
    raisecomOpticalTransceiverParameterValue              OpticalParameterValue,
    raisecomOpticalTransceiverParamHighAlarmThresh        OpticalParameterValue,
    raisecomOpticalTransceiverParamHighWarningThresh      OpticalParameterValue,
    raisecomOpticalTransceiverParamLowAlarmThresh         OpticalParameterValue,
    raisecomOpticalTransceiverParamLowWarningThresh       OpticalParameterValue,
    raisecomOpticalTransceiverParamAlarmStatus            INTEGER,
    raisecomOpticalTransceiverParamAlarmLastValue         OpticalParameterValue,
    raisecomOpticalTransceiverParamAlarmLastChange        TimeTicks,
    raisecomOpticalTransceiverDDM15MinValidIntervals      Unsigned32,
    raisecomOpticalTransceiverDDM24HrValidIntervals       Unsigned32,
    raisecomOpticalTransceiverDDMValidStatus        INTEGER 
}

raisecomOpticalTransceiverParameterType OBJECT-TYPE
    SYNTAX      OpticalParameterType
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "This object specifies the optical parameter that is being
        monitored in this entry.
        This object belongs to xfp/sfp.
		"
    ::={ raisecomOpticalTransceiverDDMEntry 1 }

raisecomOpticalTransceiverParameterValue OBJECT-TYPE
    SYNTAX      OpticalParameterValue
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This object gives the value measured for the particular
        optical parameter specified by the raisecomOpticalMonParameterType
        object.
        This object belongs to xfp/sfp.
		"
    ::={ raisecomOpticalTransceiverDDMEntry 2 }

raisecomOpticalTransceiverParamHighAlarmThresh OBJECT-TYPE
    SYNTAX      OpticalParameterValue
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This object gives the high alarm threshold on the
        optical parameter being monitored.

        An alarm condition will be raised if the value given by
        raisecomOpticalParameterValue goes from below the value of 
        this object to above the value of this object, or if
        the initial value of raisecomOpticalParameterValue exceeds the value
        of this object. This alarm will be indicated in the 
        raisecomOpticalParamAlarmStatus object.
        This object belongs to xfp/sfp.
		"
    ::={ raisecomOpticalTransceiverDDMEntry 3 }

raisecomOpticalTransceiverParamHighWarningThresh OBJECT-TYPE
    SYNTAX      OpticalParameterValue
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This object is used to set a high warning threshold on
        the optical parameter being monitored.

        A threshold crossing condition will be indicated if the value
        given by raisecomOpticalParameterValue goes from below the value
        of this object to above the value of this
        object, or if the initial value of raisecomOpticalParameterValue
        exceeds the value of this object. This alarm will be indicated in the 
        raisecomOpticalParamAlarmStatus object.
        This object belongs to xfp/sfp.
        "
    ::={ raisecomOpticalTransceiverDDMEntry 4 }

raisecomOpticalTransceiverParamLowAlarmThresh OBJECT-TYPE
    SYNTAX      OpticalParameterValue
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This object is used to set a low alarm threshold on the
        optical parameter being monitored.

        An alarm condition will be raised if the value given by
        raisecomOpticalParameterValue goes from above the value of
        this object to below the value of this object, or if
        the initial value of raisecomOpticalParameterValue is lower than the
        value of this object. This alarm
        will be indicated in the raisecomOpticalParamAlarmStatus object ..
        This object belongs to xfp/sfp.
		"
    ::={ raisecomOpticalTransceiverDDMEntry 5 }

raisecomOpticalTransceiverParamLowWarningThresh OBJECT-TYPE
    SYNTAX      OpticalParameterValue
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This object is used to set a low warning threshold on
        the optical parameter being monitored.

        A threshold crossing condition will be indicated if the value
        given by raisecomOpticalParameterValue goes from above the value
        of this object to below the value of this
        object, or if the initial value of raisecomOpticalParameterValue
        object is lower than the value of this object. For
        network elements in the status
        indications, this threshold violation will be indicated in the
        raisecomOpticalParamAlarmStatus object .
        This object belongs to xfp/sfp.
		"
    ::={ raisecomOpticalTransceiverDDMEntry 6 }

raisecomOpticalTransceiverParamAlarmStatus OBJECT-TYPE
    SYNTAX      INTEGER {
    		              unknown(0),
    		              normal(1),
    		              high-alarm(2),
                          high-warning(3),
                          low-alarm(4),
                          low-warning(5)           
                      }
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This object is used to indicate the current status of
        the thresholds for the monitored optical parameter
        on the interface.

           If a threshold is currently being exceeded on the   
           interface, the object  will be set. Otherwise, 
           the object will be set to 1.
           This object belongs to xfp/sfp.
		"
    ::={ raisecomOpticalTransceiverDDMEntry 7 }

raisecomOpticalTransceiverParamAlarmLastValue OBJECT-TYPE
    SYNTAX      OpticalParameterValue
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This object indicates the optical parameter value at the last time
        a threshold related to a particular optical parameter was
        exceeded on the interface.
        If no threshold value is currently being
        exceeded, then the value '-1000000' is returned.
        
        This object belongs to xfp/sfp.
		"
    ::={ raisecomOpticalTransceiverDDMEntry 8 }

raisecomOpticalTransceiverParamAlarmLastChange OBJECT-TYPE
    SYNTAX      TimeTicks
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This object specifies the value of sysUpTime at the last time
        a threshold related to a particular optical parameter was
        exceeded on the interface.
        
        This object belongs to xfp/sfp.
		"
    ::={ raisecomOpticalTransceiverDDMEntry 9 }

raisecomOpticalTransceiverDDM15MinValidIntervals OBJECT-TYPE
    SYNTAX      Unsigned32 (0..96)
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This object gives the number of previous 15 minute
        intervals for which valid performance monitoring data
        has been stored on the interface.

        The value of this object will be n (where n is the maximum
        number of 15 minute intervals supported at this interface),
        unless the measurement was (re-)started within the last
        (nx15) minutes, in which case the value will be the
        number of previous 15 minute intervals for which the agent
        has some data.
        
        This object belongs to xfp/sfp.
		"
    ::={ raisecomOpticalTransceiverDDMEntry 10 }

raisecomOpticalTransceiverDDM24HrValidIntervals OBJECT-TYPE
    SYNTAX      Unsigned32 (0..7)
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This object gives the number of previous 24 hour intervals
         for which valid performance monitoring data has been stored
          on the interface. The max value of this object is 7, it 
          means that the user can look up 7days history information.  
          This object belongs to xfp/sfp.
        "
    ::={ raisecomOpticalTransceiverDDMEntry 11 }
       
raisecomOpticalTransceiverDDMValidStatus OBJECT-TYPE
    SYNTAX      INTEGER {
                    unknown(0),
                    valid(1),
                    invalid(2)
                }
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This object indicates the parameter row is valid or invalid.
        The object value is 'valide' when the module is present and 
        supporting digitaldiagnotic. The object value is 'invalid' 
        when the module is absent, or when the module is present and
        not supporting digitaldiagnotic. 
        This object belongs to xfp/sfp.
       "
    ::={ raisecomOpticalTransceiverDDMEntry 12 }

-- raisecomOpticalTransceiverPMCurrent Table
raisecomOpticalTransceiverPMCurrentTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF RaisecomOpticalTransceiverPMCurrentEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "This table contains performance monitoring data for the
        various optical parameters, collected over the current 15
        minute or the current 24 hour interval."
    ::={ raisecomOpticalTransceiverPMGroup 1 }

raisecomOpticalTransceiverPMCurrentEntry OBJECT-TYPE
    SYNTAX      RaisecomOpticalTransceiverPMCurrentEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "An entry in the raisecomOpticalTransceiverPMCurrentTable. It contains
        performance monitoring data for a monitored optical
        parameter at an interface, collected over the current 15
        minute or the current 24 hour interval.
        "
    INDEX       { ifIndex,                  
                  raisecomOpticalTransceiverPMCurrentPeriod,
				  raisecomOpticalTransceiverPMCurrentParamType }
    ::={ raisecomOpticalTransceiverPMCurrentTable 1 }

RaisecomOpticalTransceiverPMCurrentEntry ::= SEQUENCE {
    raisecomOpticalTransceiverPMCurrentPeriod             OpticalPMPeriod,
    raisecomOpticalTransceiverPMCurrentParamType          OpticalParameterType,
    raisecomOpticalTransceiverPMCurrentMaxParam           OpticalParameterValue,
    raisecomOpticalTransceiverPMCurrentMinParam           OpticalParameterValue,
    raisecomOpticalTransceiverPMCurrentMeanParam          OpticalParameterValue
}

raisecomOpticalTransceiverPMCurrentPeriod OBJECT-TYPE
    SYNTAX      OpticalPMPeriod
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "This object indicates whether the optical parameter values
        given in this entry are collected over the current 15 minute or
        the current 24 hour interval.
        This object belongs to xfp/sfp.
		"
    ::={ raisecomOpticalTransceiverPMCurrentEntry 1 }

raisecomOpticalTransceiverPMCurrentParamType OBJECT-TYPE
    SYNTAX      OpticalParameterType
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "This object specifies the optical parameter that is being
        monitored, in this entry.
        This object belongs to xfp/sfp.
		"
    ::={ raisecomOpticalTransceiverPMCurrentEntry 2 }

raisecomOpticalTransceiverPMCurrentMaxParam OBJECT-TYPE
    SYNTAX      OpticalParameterValue
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This object gives the maximum value measured for the monitored
        optical parameter, in the current 15 minute or the current
        24 hour interval.
        This object belongs to xfp/sfp.
		"
    ::={ raisecomOpticalTransceiverPMCurrentEntry 3 }

raisecomOpticalTransceiverPMCurrentMinParam OBJECT-TYPE
    SYNTAX      OpticalParameterValue
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This object gives the minimum value measured for the monitored
        optical parameter, in the current 15 minute or the current
        24 hour interval.
        This object belongs to xfp/sfp.
		"
    ::={ raisecomOpticalTransceiverPMCurrentEntry 4 }

raisecomOpticalTransceiverPMCurrentMeanParam OBJECT-TYPE
    SYNTAX      OpticalParameterValue
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This object gives the average value of the monitored
        optical parameter, in the current 15 minute or the current
        24 hour interval.
        This object belongs to xfp/sfp.
		"
    ::={ raisecomOpticalTransceiverPMCurrentEntry 5 }

-- raisecomOpticalTransceiverPMInterval Table

raisecomOpticalTransceiverPMIntervalTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF RaisecomOpticalTransceiverPMIntervalEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "This table stores performance monitoring data for the
        various optical parameters, collected over previous
        intervals.

        This table can have entries for one complete 24 hour
        interval and up to 96 complete 15 minute
        intervals. A system is required to store at least
        4 completed 15 minute intervals. The number of valid
        15 minute intervals in this table is indicated by the
        raisecomOpticalTransceiverDDM15MinValidIntervals object 
        and the number of valid 24 hour intervals is indicated by the
        raisecomOpticalTransceiverDDM24HrValidIntervals object.
        
        when the optical module is removed from the device, the relative 
        history records will be cleaned.
        "
    ::={ raisecomOpticalTransceiverPMGroup 2 }

raisecomOpticalTransceiverPMIntervalEntry OBJECT-TYPE
    SYNTAX      RaisecomOpticalTransceiverPMIntervalEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "An entry in the raisecomOpticalTransceiverPMIntervalTable. It contains
        performance monitoring data for an optical parameter,
        collected over a previous interval.
        "
    INDEX      { ifIndex,
    			 raisecomOpticalTransceiverPMIntervalPeriod,
                 raisecomOpticalTransceiverPMIntervalNumber,                 
                 raisecomOpticalTransceiverPMIntervalParamType }
    ::={ raisecomOpticalTransceiverPMIntervalTable 1 }

RaisecomOpticalTransceiverPMIntervalEntry ::= SEQUENCE {
    raisecomOpticalTransceiverPMIntervalPeriod            OpticalPMPeriod,
    raisecomOpticalTransceiverPMIntervalNumber            Integer32,
    raisecomOpticalTransceiverPMIntervalParamType         OpticalParameterType,
    raisecomOpticalTransceiverPMIntervalMaxParam          OpticalParameterValue,
    raisecomOpticalTransceiverPMIntervalMinParam          OpticalParameterValue,
    raisecomOpticalTransceiverPMIntervalMeanParam         OpticalParameterValue
    }

raisecomOpticalTransceiverPMIntervalPeriod OBJECT-TYPE
    SYNTAX      OpticalPMPeriod
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "This object indicates whether the optical parameter values,
        given in this entry, are collected over a period of 15 minutes
        or 24 hours.
        This object belongs to xfp/sfp.
		"
    ::={ raisecomOpticalTransceiverPMIntervalEntry 1 }

raisecomOpticalTransceiverPMIntervalNumber OBJECT-TYPE
    SYNTAX      Integer32 (1..96)
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "A number between 1 and 96, which identifies the
         interval for which the set of optical parameter values is
         available. The interval identified by 1 is the most recently
         completed 15 minute or 24 hour interval, and the interval
         identified by N is the interval immediately preceding the one
         identified by N-1.
         This object belongs to xfp/sfp.
		"
    ::={ raisecomOpticalTransceiverPMIntervalEntry 2 }

raisecomOpticalTransceiverPMIntervalParamType OBJECT-TYPE
    SYNTAX      OpticalParameterType
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "This object specifies the optical parameter that is being
        monitored, in this entry.
        This object belongs to xfp/sfp.
 		"
    ::={ raisecomOpticalTransceiverPMIntervalEntry 3 }

raisecomOpticalTransceiverPMIntervalMaxParam OBJECT-TYPE
    SYNTAX      OpticalParameterValue
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This object gives the maximum value measured for the optical
        parameter, in a particular 15 minute or 24 hour interval.
        This object belongs to xfp/sfp.
		"
    ::={ raisecomOpticalTransceiverPMIntervalEntry 4 }

raisecomOpticalTransceiverPMIntervalMinParam OBJECT-TYPE
    SYNTAX      OpticalParameterValue
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This object gives the minimum value measured for the optical
        parameter, in a particular 15 minute or 24 hour interval.
        This object belongs to xfp/sfp.
		"
    ::={ raisecomOpticalTransceiverPMIntervalEntry 5 }

raisecomOpticalTransceiverPMIntervalMeanParam OBJECT-TYPE
    SYNTAX      OpticalParameterValue
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This object gives the average value of the measured optical
        parameter, in a particular 15 minute or 24 hour interval.
        This object belongs to xfp/sfp.
		"
    ::={ raisecomOpticalTransceiverPMIntervalEntry 6 }

-- raisecomOpticalTransceiverCurrentStatus Table
raisecomOpticalTransceiverCurrentStatusTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF RaisecomOpticalTransceiverCurrentStatusEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "This table stores the hard ware information and the information
        set by user of the transceiver. 
        This object belongs to xfp/sfp.
        "
    ::={ raisecomOpticalTransceiverStatusGroup 1 }

raisecomOpticalTransceiverCurrentStatusEntry OBJECT-TYPE
    SYNTAX      RaisecomOpticalTransceiverCurrentStatusEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "An entry in the raisecomOpticalTransceiverCurrentStatusTable. It contains
        performance monitoring data for an optical parameter,
        collected over a previous interval.
        This object belongs to xfp/sfp.
        "
    INDEX      { ifIndex   }
    ::={ raisecomOpticalTransceiverCurrentStatusTable 1 }

RaisecomOpticalTransceiverCurrentStatusEntry ::= SEQUENCE {
    raisecomOpticalTransceiverHwInfoAbsStatus            INTEGER,
    raisecomOpticalTransceiverHwInfoNRStatus            INTEGER,
    raisecomOpticalTransceiverHwInfoRxLosStatus         INTEGER,
    raisecomOpticalTransceiverHwInfoStandby          INTEGER,
    raisecomOpticalTransceiverHwInfoLaser            INTEGER,
    raisecomOpticalTransceiverWaveLengthError         Integer32,    
    raisecomOpticalTransceiverUserWaveLength          Integer32, 
    raisecomOpticalTransceiverUserDataRate                INTEGER,
    raisecomOpticalTransceiverUserLineLoopBack            INTEGER,
    raisecomOpticalTransceiverUserXFILoopBack             INTEGER,
    raisecomOpticalTransceiverPortNotifyEnable            EnableVar,
    raisecomOpticalTransceiverPortDDMEnable               EnableVar,
    raisecomOpticalTransceiverPortCheckPwdEnable          EnableVar,
    raisecomOpticalTransceiverTxFaultCount                Integer32, 
    raisecomOpticalTransceiverTxFaultCountClear           ClearVar,
    raisecomOpticalTransceiverSpecificationCheckStatus    INTEGER,
    raisecomOpticalTransceiverTxFaultStatus               INTEGER
    }

raisecomOpticalTransceiverHwInfoAbsStatus         OBJECT-TYPE
    SYNTAX      INTEGER
    {
 		absent(1),
    	present(2)
    }
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This object specifies if the optical module is absent
        present,absent.
        This object belongs to xfp and sfp."
    ::={ raisecomOpticalTransceiverCurrentStatusEntry 1 }

raisecomOpticalTransceiverHwInfoNRStatus          OBJECT-TYPE
    SYNTAX      INTEGER
    {
    	ready(1),
       	notready(2)
    }
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This object specifies if the optical module is ready for operation.
        ready,notready.
        This object belongs to xfp.
        "
    ::={ raisecomOpticalTransceiverCurrentStatusEntry 2 }

raisecomOpticalTransceiverHwInfoRxLosStatus      OBJECT-TYPE
    SYNTAX      INTEGER
    {
    	 normal(1),
       	 loss(2)
    }
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This object specifies if the optical module operation losses the receiving signal
        normal,loss.
        This object belongs to xfp.
        "
    ::={ raisecomOpticalTransceiverCurrentStatusEntry 3 }

raisecomOpticalTransceiverHwInfoStandby       OBJECT-TYPE
    SYNTAX      INTEGER
    {
 		normal(1),
       	standby(2)
    }
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "This object specifies if the optical module works under standby mode.
        normal,standby.
        This object belongs to xfp.
        "
    ::={ raisecomOpticalTransceiverCurrentStatusEntry 4 }

raisecomOpticalTransceiverHwInfoLaser       OBJECT-TYPE
    SYNTAX      INTEGER
    {
 		on(1),
       	off(2)
    }
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "This object specifies if the optical module laser is turned on
        on,off.
        This object belongs to xfp.
        "
    ::={ raisecomOpticalTransceiverCurrentStatusEntry 5 }

raisecomOpticalTransceiverWaveLengthError         OBJECT-TYPE
    SYNTAX      Integer32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This object specifies error between the actual wavelength 
        and the wavelength set by the user,measured in pm.
        This object belongs to xfp.
        The object will be shown in unit of nm, and the precision is 0.001.
       "
    ::={ raisecomOpticalTransceiverCurrentStatusEntry 6 }   

raisecomOpticalTransceiverUserWaveLength          OBJECT-TYPE
    SYNTAX      Integer32(0..3276800)
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "This object specifies the wavelength value of the optical module set by user,measured in pm.
         This object belongs to xfp.
         The object will be shown in unit of nm, and the precision is 0.01.
        "
    ::={ raisecomOpticalTransceiverCurrentStatusEntry 7 }
                                
                                 
raisecomOpticalTransceiverUserDataRate                OBJECT-TYPE
    SYNTAX      INTEGER(9500..12500) 
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "This object specifies the data rate of the optical module set by user,measured in Mbps.
         This object belongs to xfp.
         The object will be shown in unit of Gbps, and the precision is 0.1.
        "
    ::={ raisecomOpticalTransceiverCurrentStatusEntry 8 }    
     
raisecomOpticalTransceiverUserLineLoopBack            OBJECT-TYPE
    SYNTAX      INTEGER
	{
 		normal(1),
       	lineLoopback(2)
	}
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "This object specifies if the sideline loop-back is tuned on , 
        user can change the loop back mode through the object.
        normal,lineLoopback.
        This object belongs to xfp.
        "
    ::={ raisecomOpticalTransceiverCurrentStatusEntry 9 }
    
raisecomOpticalTransceiverUserXFILoopBack             OBJECT-TYPE
    SYNTAX      INTEGER
	{
 		normal(1),
       	xfiLoopback(2)
	}
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "This object specifies if the XFI loop-back is tuned on 
        user can change the loop back mode through the object.
        normal,xfiLoopback.
        This object belongs to xfp.
        "
    ::={ raisecomOpticalTransceiverCurrentStatusEntry 10 }    

raisecomOpticalTransceiverPortNotifyEnable OBJECT-TYPE
    SYNTAX      EnableVar
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "This object specifies the generation of a port notifications,
         enable or disable.  
         This object belongs to xfp and sfp.
        "
    DEFVAL { enable}
    ::={ raisecomOpticalTransceiverCurrentStatusEntry 11 }

raisecomOpticalTransceiverPortDDMEnable OBJECT-TYPE
    SYNTAX      EnableVar
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "This object specifies the status of digitaldiagnotic on a port, 
         enable or disable.  
         This object belongs to xfp and sfp.
        "
    DEFVAL { enable}
    ::={ raisecomOpticalTransceiverCurrentStatusEntry 12 }

raisecomOpticalTransceiverPortCheckPwdEnable OBJECT-TYPE
    SYNTAX      EnableVar
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "This object specifies the status of password checking on a port, 
        enable or disable.  
        This object belongs to xfp.
        "
    DEFVAL { enable}
    ::={ raisecomOpticalTransceiverCurrentStatusEntry 13 }  
    
    raisecomOpticalTransceiverTxFaultCount OBJECT-TYPE
    SYNTAX      Integer32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This object specifies the number of tx-fault signals."
    ::={ raisecomOpticalTransceiverCurrentStatusEntry 14 }  
    
    raisecomOpticalTransceiverTxFaultCountClear OBJECT-TYPE
    SYNTAX      ClearVar
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "This object specifies clear the statistcs of tx-fault signals."
    ::={ raisecomOpticalTransceiverCurrentStatusEntry 15 } 
    
    raisecomOpticalTransceiverSpecificationCheckStatus OBJECT-TYPE
    SYNTAX      INTEGER{none(0),accord(1),not-accord(2)}
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This object specifies the check status, accord(0)specifies 
        the optical module accord with industrial. not-accord(2)
        specifies the optical module not accord with industrial."
    ::={ raisecomOpticalTransceiverCurrentStatusEntry 16 } 
    
    raisecomOpticalTransceiverTxFaultStatus OBJECT-TYPE
    SYNTAX      INTEGER{normal(1),tx-fault(2)}
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This object specifies the tx-fault status."
    ::={ raisecomOpticalTransceiverCurrentStatusEntry 17 }
    
 
-- Notifications

raisecomOpticalTransceiverNotifications OBJECT IDENTIFIER ::=
                                 { raisecomOpticalTransceiver 3 }

raisecomOpticalTransceiverAbsentTrap NOTIFICATION-TYPE
    OBJECTS     { raisecomOpticalTransceiverHwInfoAbsStatus }
    STATUS      current
    DESCRIPTION
        "This notification is sent when the optical module is removed from the device.

        This notification may be suppressed under the following
        conditions:
        - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
        "
    ::={ raisecomOpticalTransceiverNotifications 1 }

raisecomOpticalTransceiverPresentTrap  NOTIFICATION-TYPE
    OBJECTS     { raisecomOpticalTransceiverHwInfoAbsStatus,
                  raisecomOpticalTransceiverSpecificationCheckStatus }
    STATUS      current
    DESCRIPTION
        "This notification is sent when the optical module is plugged into the device.

        This notification may be suppressed under the following
        conditions:
        - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
        "
    ::={ raisecomOpticalTransceiverNotifications 2 }

raisecomOpticalTransceiverNRAlarmTrap  NOTIFICATION-TYPE
    OBJECTS     { raisecomOpticalTransceiverHwInfoNRStatus }
    STATUS      current
    DESCRIPTION
        "This notification is sent when the transmitted or received data of optical module is invalid.

        This notification may be suppressed under the following
        conditions:
        - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
        "
    ::={ raisecomOpticalTransceiverNotifications 3 }

raisecomOpticalTransceiverNRNormalTrap  NOTIFICATION-TYPE
    OBJECTS     { raisecomOpticalTransceiverHwInfoNRStatus  }
    STATUS      current
    DESCRIPTION
        "This notification is sent when the transmitted or received data of optical module is valid.

        This notification may be suppressed under the following
        conditions:
        - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
        "
    ::={ raisecomOpticalTransceiverNotifications 4 }

raisecomOpticalTransceiverRxLosAlarmTrap  NOTIFICATION-TYPE
    OBJECTS     { raisecomOpticalTransceiverHwInfoRxLosStatus }
    STATUS      current
    DESCRIPTION
        "This notification is sent when the optical module receiving signal is lost.

        This notification may be suppressed under the following
        conditions:
        - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
        "
    ::={ raisecomOpticalTransceiverNotifications 5 }

raisecomOpticalTransceiverRxLosNormaTrap   NOTIFICATION-TYPE
    OBJECTS     {raisecomOpticalTransceiverHwInfoRxLosStatus  }
    STATUS      current
    DESCRIPTION
        "This notification is sent when the optical module receiving signal is back to normal.

        This notification may be suppressed under the following
        conditions:
        - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
        "
    ::={ raisecomOpticalTransceiverNotifications 6 }

raisecomOpticalTransceiverCheckPwdFailureTrap  NOTIFICATION-TYPE
    STATUS      current
    DESCRIPTION
        "This notification is sent when the optical module password checking is failed.

        This notification may be suppressed under the following
        conditions:
        - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
        "
    ::={ raisecomOpticalTransceiverNotifications 7 }

raisecomOpticalTransceiverCheckPwdSucceedTrap  NOTIFICATION-TYPE
    STATUS      current
    DESCRIPTION
        "This notification is sent when the optical module password cheching is successful.

        This notification may be suppressed under the following
        conditions:
        - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
        "
    ::={ raisecomOpticalTransceiverNotifications 8 }

raisecomOpticalTransceiverParamAlarmTrap    NOTIFICATION-TYPE
    OBJECTS     {  raisecomOpticalTransceiverParameterValue,
                   raisecomOpticalTransceiverParamAlarmStatus  }
    STATUS      current
    DESCRIPTION
        "This notification is sent when the optical module parameter value increase to above 
         the high alarm threshold or dicrease to under the low alarm threshold.


        This notification may be suppressed under the following
        conditions:
        - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
        "
    ::={ raisecomOpticalTransceiverNotifications 9 }

raisecomOpticalTransceiverParamAlarmNormalTrap   NOTIFICATION-TYPE
    OBJECTS     {  raisecomOpticalTransceiverParameterValue,
                   raisecomOpticalTransceiverParamAlarmStatus  }
    STATUS      current
    DESCRIPTION
        "This notification is sent when the optical module parameter value dicrease to
 	     under the high alarm threshold or increase to above the low alarm threshold.

        This notification may be suppressed under the following
        conditions:
        - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
        "
    ::={ raisecomOpticalTransceiverNotifications 10 }

raisecomOpticalTransceiverParamWarningTrap   NOTIFICATION-TYPE
    OBJECTS     {  raisecomOpticalTransceiverParameterValue,
                   raisecomOpticalTransceiverParamAlarmStatus  }
    STATUS      current
    DESCRIPTION
        "This notification is sent when the optical module parameter value increase to above 
     	the high warning threshold or dicrease to under the low warning threshold.

        This notification may be suppressed under the following
        conditions:
        - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
        "
    ::={ raisecomOpticalTransceiverNotifications 11 }

raisecomOpticalTransceiverParamWarningNormalTrap   NOTIFICATION-TYPE
    OBJECTS     {  raisecomOpticalTransceiverParameterValue,
                   raisecomOpticalTransceiverParamAlarmStatus  }
    STATUS      current
    DESCRIPTION
        "This notification is sent when the optical module parameter value dicrease to
    	under the high warning threshold or increase to above the low warning threshold.   
    	
        This notification may be suppressed under the following
        conditions:
        - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
        "
    ::={ raisecomOpticalTransceiverNotifications 12 }

raisecomOpticalTransceiverLaserBackLightAlarmTrap   NOTIFICATION-TYPE
    OBJECTS     {  raisecomOpticalTransceiverParameterValue,
                   raisecomOpticalTransceiverParamAlarmStatus  }
    STATUS      current
    DESCRIPTION
        "This notification is sent when the optical module password cheching is successful.

        This notification may be suppressed under the following
        conditions:
        - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
        "
    ::={ raisecomOpticalTransceiverNotifications 13 }

raisecomOpticalTransceiverLaserBackLightAlarmNormalTrap   NOTIFICATION-TYPE
    OBJECTS     {  raisecomOpticalTransceiverParameterValue,
                   raisecomOpticalTransceiverParamAlarmStatus  }

    STATUS      current
    DESCRIPTION
        "This notification is sent when the optical module password cheching is successful.

        This notification may be suppressed under the following
        conditions:
        - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
        "
    ::={ raisecomOpticalTransceiverNotifications 14 }
   
raisecomOpticalTransceiverLaserLifeAlarmTrap   NOTIFICATION-TYPE
    OBJECTS     {  raisecomOpticalTransceiverParameterValue,
                   raisecomOpticalTransceiverParamAlarmStatus  }

    STATUS      current
    DESCRIPTION
        "This notification is sent when the optical module password cheching is successful.

        This notification may be suppressed under the following
        conditions:
        - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
        "
    ::={ raisecomOpticalTransceiverNotifications 15 }
   
raisecomOpticalTransceiverLaserLifeAlarmNormalTrap   NOTIFICATION-TYPE
    OBJECTS     {  raisecomOpticalTransceiverParameterValue,
                   raisecomOpticalTransceiverParamAlarmStatus  }

    STATUS      current
    DESCRIPTION
        "This notification is sent when the optical module password cheching is successful.

        This notification may be suppressed under the following
        conditions:
        - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
        "
    ::={ raisecomOpticalTransceiverNotifications 16 }

raisecomOpticalTransceiverParamLowAlarmTrap    NOTIFICATION-TYPE
    OBJECTS     {  raisecomOpticalTransceiverParameterValue,
                   raisecomOpticalTransceiverParamAlarmStatus  }
    STATUS      current
    DESCRIPTION
        "This notification is sent when the optical module parameter value increase to above 
         the high alarm threshold or dicrease to under the low alarm threshold.


        This notification may be suppressed under the following
        conditions:
        - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
        "
    ::={ raisecomOpticalTransceiverNotifications 17 }


raisecomOpticalTransceiverParamLowAlarmNormalTrap    NOTIFICATION-TYPE
    OBJECTS     {  raisecomOpticalTransceiverParameterValue,
                   raisecomOpticalTransceiverParamAlarmStatus  }
    STATUS      current
    DESCRIPTION
        "This notification is sent when the optical module parameter value increase to above 
         the high alarm threshold or dicrease to under the low alarm threshold.


        This notification may be suppressed under the following
        conditions:
        - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
        "
    ::={ raisecomOpticalTransceiverNotifications 18 } 
    
raisecomOpticalTransceiverParamLowWarningTrap    NOTIFICATION-TYPE
    OBJECTS     {  raisecomOpticalTransceiverParameterValue,
                   raisecomOpticalTransceiverParamAlarmStatus  }
    STATUS      current
    DESCRIPTION
        "This notification is sent when the optical module parameter value increase to above 
         the high alarm threshold or dicrease to under the low alarm threshold.


        This notification may be suppressed under the following
        conditions:
        - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
        "
    ::={ raisecomOpticalTransceiverNotifications 19 }

raisecomOpticalTransceiverParamLowWarningNormalTrap    NOTIFICATION-TYPE
    OBJECTS     {  raisecomOpticalTransceiverParameterValue,
                   raisecomOpticalTransceiverParamAlarmStatus  }
    STATUS      current
    DESCRIPTION
        "This notification is sent when the optical module parameter value increase to above 
         the high alarm threshold or dicrease to under the low alarm threshold.


        This notification may be suppressed under the following
        conditions:
        - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
        "
    ::={ raisecomOpticalTransceiverNotifications 20 }

      
-- Parameters and Notifications

raisecomOpticalTransceiverParamNotifications OBJECT IDENTIFIER ::=
                                 { raisecomOpticalTransceiver 4 }
                                 
raisecomOpticalTransceiverTemperatureAlarmTrap    NOTIFICATION-TYPE
    OBJECTS     {  raisecomNotificationLocation,
                   raisecomOpticalTransceiverParameterValue,
                   raisecomOpticalTransceiverParamAlarmStatus  }
    STATUS      current
    DESCRIPTION
        "This notification is sent when the optical module Temperature value increase to above 
         the high alarm threshold or dicrease to under the low alarm threshold.

        This notification may be suppressed under the following
        conditions:
        - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
        "
    ::={ raisecomOpticalTransceiverParamNotifications 1 }

raisecomOpticalTransceiverTemperatureAlarmNormalTrap   NOTIFICATION-TYPE
    OBJECTS     {  raisecomNotificationLocation,
                   raisecomOpticalTransceiverParameterValue,
                   raisecomOpticalTransceiverParamAlarmStatus  }

    STATUS      current
    DESCRIPTION
        "This notification is sent when the optical module Temperature value dicrease to
         under the high alarm threshold or increase to above the low alarm threshold.

        This notification may be suppressed under the following
        conditions:
        - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
        "
    ::={ raisecomOpticalTransceiverParamNotifications 2 }

raisecomOpticalTransceiverTemperatureWarningTrap   NOTIFICATION-TYPE
    OBJECTS     {  raisecomNotificationLocation,
                   raisecomOpticalTransceiverParameterValue,
                   raisecomOpticalTransceiverParamAlarmStatus  }
    STATUS      current
    DESCRIPTION
        "This notification is sent when the optical module Temperature value increase to above 
         the high warning threshold or dicrease to under the low warning threshold.

        This notification may be suppressed under the following
        conditions:
        - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
        "
    ::={ raisecomOpticalTransceiverParamNotifications 3 }

raisecomOpticalTransceiverTemperatureWarningNormalTrap   NOTIFICATION-TYPE
    OBJECTS     {  raisecomNotificationLocation,
                   raisecomOpticalTransceiverParameterValue,
                   raisecomOpticalTransceiverParamAlarmStatus  }
    STATUS      current
    DESCRIPTION
        "This notification is sent when the optical module Temperature value dicrease to
         under the high warning threshold or increase to above the low warning threshold.

        This notification may be suppressed under the following
        conditions:
        - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
        "
    ::={ raisecomOpticalTransceiverParamNotifications 4 }

raisecomOpticalTransceiverTxbiasCurrentAlarmTrap   NOTIFICATION-TYPE
    OBJECTS     {  raisecomNotificationLocation,
                   raisecomOpticalTransceiverParameterValue,
                   raisecomOpticalTransceiverParamAlarmStatus  }
    STATUS      current
    DESCRIPTION
        "This notification is sent when the optical module Tx bias Current value increase to above 
         the high alarm threshold or dicrease to under the low alarm threshold.

        This notification may be suppressed under the following
        conditions:
        - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
        "
    ::={ raisecomOpticalTransceiverParamNotifications 5 }

raisecomOpticalTransceiverTxbiasCurrentAlarmNormalTrap   NOTIFICATION-TYPE
    OBJECTS     {  raisecomNotificationLocation,
                   raisecomOpticalTransceiverParameterValue,
                   raisecomOpticalTransceiverParamAlarmStatus  }
    STATUS      current
    DESCRIPTION
        "This notification is sent when the optical module Tx bias Current value dicrease to
         under the high alarm threshold or increase to above the low alarm threshold.
         
        This notification may be suppressed under the following
        conditions:
        - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
        "
    ::={ raisecomOpticalTransceiverParamNotifications 6 }
 
raisecomOpticalTransceiverTxbiasCurrentWarningTrap   NOTIFICATION-TYPE
    OBJECTS     {  raisecomNotificationLocation,
                   raisecomOpticalTransceiverParameterValue,
                   raisecomOpticalTransceiverParamAlarmStatus  }
    STATUS      current
    DESCRIPTION
        "This notification is sent when the optical module Tx bias Current value increase to above 
         the high warning threshold or dicrease to under the low warning threshold.

        This notification may be suppressed under the following
        conditions:
        - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
        "
    ::={ raisecomOpticalTransceiverParamNotifications 7 }

raisecomOpticalTransceiverTxbiasCurrentWarningNormalTrap   NOTIFICATION-TYPE
    OBJECTS     {  raisecomNotificationLocation,
                   raisecomOpticalTransceiverParameterValue,
                   raisecomOpticalTransceiverParamAlarmStatus  }
    STATUS      current
    DESCRIPTION
        "This notification is sent when the optical module Tx bias Current value dicrease to
         under the high warning threshold or increase to above the low warning threshold.

        This notification may be suppressed under the following
        conditions:
        - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
        "
    ::={ raisecomOpticalTransceiverParamNotifications 8 }

raisecomOpticalTransceiverTxPowerAlarmTrap   NOTIFICATION-TYPE
    OBJECTS     {  raisecomNotificationLocation,
                   raisecomOpticalTransceiverParameterValue,
                   raisecomOpticalTransceiverParamAlarmStatus  }
    STATUS      current
    DESCRIPTION
        "This notification is sent when the optical module Tx Power value increase to above 
         the high alarm threshold or dicrease to under the low alarm threshold.

        This notification may be suppressed under the following
        conditions:
        - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
        "
    ::={ raisecomOpticalTransceiverParamNotifications 9 }

raisecomOpticalTransceiverTxPowerAlarmNormalTrap   NOTIFICATION-TYPE
    OBJECTS     {  raisecomNotificationLocation,
                   raisecomOpticalTransceiverParameterValue,
                   raisecomOpticalTransceiverParamAlarmStatus  }

    STATUS      current
    DESCRIPTION
        "This notification is sent when the optical module Tx Power value dicrease to
         under the high alarm threshold or increase to above the low alarm threshold.

        This notification may be suppressed under the following
        conditions:
        - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
        "
    ::={ raisecomOpticalTransceiverParamNotifications 10 }

raisecomOpticalTransceiverTxPowerWarningTrap   NOTIFICATION-TYPE
    OBJECTS     {  raisecomNotificationLocation,
                   raisecomOpticalTransceiverParameterValue,
                   raisecomOpticalTransceiverParamAlarmStatus  }
    STATUS      current
    DESCRIPTION
        "This notification is sent when the optical module  Tx Power value increase to above 
         the high warning threshold or dicrease to under the low warning threshold.
                  
        This notification may be suppressed under the following
        conditions:
        - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
        "
    ::={ raisecomOpticalTransceiverParamNotifications 11 }

raisecomOpticalTransceiverTxPowerWarningNormalTrap   NOTIFICATION-TYPE
    OBJECTS     {  raisecomNotificationLocation,
                   raisecomOpticalTransceiverParameterValue,
                   raisecomOpticalTransceiverParamAlarmStatus  }

    STATUS      current
    DESCRIPTION
        "This notification is sent when the optical module Tx Power value dicrease to
         under the high warning threshold or increase to above the low warning threshold.

        This notification may be suppressed under the following
        conditions:
        - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
        "
    ::={ raisecomOpticalTransceiverParamNotifications 12 }

raisecomOpticalTransceiverRxPowerAlarmTrap   NOTIFICATION-TYPE
    OBJECTS     {  raisecomNotificationLocation,
                   raisecomOpticalTransceiverParameterValue,
                   raisecomOpticalTransceiverParamAlarmStatus  }
    STATUS      current
    DESCRIPTION
        "This notification is sent when the optical module Rx Power value increase to above 
         the high alarm threshold or dicrease to under the low alarm threshold.

        This notification may be suppressed under the following
        conditions:
        - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
        "
    ::={ raisecomOpticalTransceiverParamNotifications 13 }

raisecomOpticalTransceiverRxPowerWarningTrap   NOTIFICATION-TYPE
    OBJECTS     {  raisecomNotificationLocation,
                   raisecomOpticalTransceiverParameterValue,
                   raisecomOpticalTransceiverParamAlarmStatus  }
    STATUS      current
    DESCRIPTION
        "This notification is sent when the optical module Rx Power value increase to above 
         the high warning threshold or dicrease to under the low warning threshold.

        This notification may be suppressed under the following
        conditions:
        - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
        "
    ::={ raisecomOpticalTransceiverParamNotifications 14 }
 
raisecomOpticalTransceiverRxPowerWarningNormalTrap   NOTIFICATION-TYPE
    OBJECTS     {  raisecomNotificationLocation,
                   raisecomOpticalTransceiverParameterValue,
                   raisecomOpticalTransceiverParamAlarmStatus  }
    STATUS      current
    DESCRIPTION
        "This notification is sent when the optical module Rx Power value dicrease to
         under the high warning threshold or increase to above the low warning threshold.
         
        This notification may be suppressed under the following
        conditions:
        - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
        "
    ::={ raisecomOpticalTransceiverParamNotifications 15 }

raisecomOpticalTransceiverRxPowerAlarmNormalTrap   NOTIFICATION-TYPE
    OBJECTS     {  raisecomNotificationLocation,
                   raisecomOpticalTransceiverParameterValue,
                   raisecomOpticalTransceiverParamAlarmStatus  }
    STATUS      current
    DESCRIPTION
        "This notification is sent when the optical module Rx Power value dicrease to
         under the high alarm threshold or increase to above the low alarm threshold.

        This notification may be suppressed under the following
        conditions:
        - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
        "
    ::={ raisecomOpticalTransceiverParamNotifications 16 }
   
raisecomOpticalTransceiverLaserTemperatureAlarmTrap   NOTIFICATION-TYPE
    OBJECTS     {  raisecomNotificationLocation,
                   raisecomOpticalTransceiverParameterValue,
                   raisecomOpticalTransceiverParamAlarmStatus  }

    STATUS      current
    DESCRIPTION
        "This notification is sent when the optical module Laser Temperature value increase to above 
         the high alarm threshold or dicrease to under the low alarm threshold.

        This notification may be suppressed under the following
        conditions:
        - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
        "
    ::={ raisecomOpticalTransceiverParamNotifications 17 }
   
raisecomOpticalTransceiverLaserTemperatureWarningTrap   NOTIFICATION-TYPE
    OBJECTS     {  raisecomNotificationLocation,
                   raisecomOpticalTransceiverParameterValue,
                   raisecomOpticalTransceiverParamAlarmStatus  }
    STATUS      current
    DESCRIPTION
        "This notification is sent when the optical module Laser Temperature  value increase to above 
         the high warning threshold or dicrease to under the low warning threshold.

        This notification may be suppressed under the following
        conditions:
        - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
        "
    ::={ raisecomOpticalTransceiverParamNotifications 18 }
   
raisecomOpticalTransceiverLaserTemperatureWarningNormalTrap   NOTIFICATION-TYPE
    OBJECTS     {  raisecomNotificationLocation,
                   raisecomOpticalTransceiverParameterValue,
                   raisecomOpticalTransceiverParamAlarmStatus  }

    STATUS      current
    DESCRIPTION
        "This notification is sent when the optical module Laser Temperature value dicrease to
         under the high warning threshold or increase to above the low warning threshold.
         
        This notification may be suppressed under the following
        conditions:
        - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
        "
    ::={ raisecomOpticalTransceiverParamNotifications 19 }
   
raisecomOpticalTransceiverLaserTemperatureAlarmNormalTrap   NOTIFICATION-TYPE
    OBJECTS     {  raisecomNotificationLocation,
                   raisecomOpticalTransceiverParameterValue,
                   raisecomOpticalTransceiverParamAlarmStatus  }
    STATUS      current
    DESCRIPTION
        "This notification is sent when the optical module Laser Temperature value dicrease to
         under the high alarm threshold or increase to above the low alarm threshold.

        This notification may be suppressed under the following
        conditions:
        - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
        "
    ::={ raisecomOpticalTransceiverParamNotifications 20 }
   
raisecomOpticalTransceiverP5V0supplyVoltageAlarmTrap   NOTIFICATION-TYPE
    OBJECTS     {  raisecomNotificationLocation,
                   raisecomOpticalTransceiverParameterValue,
                   raisecomOpticalTransceiverParamAlarmStatus  }
    STATUS      current
    DESCRIPTION
        "This notification is sent when the optical module +5.0V supply Voltage value increase to above 
         the high alarm threshold or dicrease to under the low alarm threshold.
        This notification may be suppressed under the following
        conditions:
        - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
        "
    ::={ raisecomOpticalTransceiverParamNotifications 21 }
   
raisecomOpticalTransceiverP5V0supplyVoltageWarningTrap   NOTIFICATION-TYPE
    OBJECTS     {  raisecomNotificationLocation,
                   raisecomOpticalTransceiverParameterValue,
                   raisecomOpticalTransceiverParamAlarmStatus  }

    STATUS      current
    DESCRIPTION
        "This notification is sent when the optical module +5.0V supply Voltage value increase to above 
         the high warning threshold or dicrease to under the low warning threshold.

        This notification may be suppressed under the following
        conditions:
        - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
        "
    ::={ raisecomOpticalTransceiverParamNotifications 22 }
   
raisecomOpticalTransceiverP5V0supplyVoltageWarningNormalTrap   NOTIFICATION-TYPE
    OBJECTS     {  raisecomNotificationLocation,
                   raisecomOpticalTransceiverParameterValue,
                   raisecomOpticalTransceiverParamAlarmStatus  }
    STATUS      current
    DESCRIPTION
        "This notification is sent when the optical module +5.0V supply Voltage value dicrease to
         under the high warning threshold or increase to above the low warning threshold.

        This notification may be suppressed under the following
        conditions:
        - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
        "
    ::={ raisecomOpticalTransceiverParamNotifications 23 }

raisecomOpticalTransceiverP5V0supplyVoltageAlarmNormalTrap   NOTIFICATION-TYPE
    OBJECTS     {  raisecomNotificationLocation,
                   raisecomOpticalTransceiverParameterValue,
                   raisecomOpticalTransceiverParamAlarmStatus  }
    STATUS      current
    DESCRIPTION
        "This notification is sent when the optical module +5.0V supply Voltage value dicrease to
         under the high alarm threshold or increase to above the low alarm threshold.

        This notification may be suppressed under the following
        conditions:
        - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
        "
    ::={ raisecomOpticalTransceiverParamNotifications 24 }
 
raisecomOpticalTransceiverP3V3supplyVoltageAlarmTrap   NOTIFICATION-TYPE
    OBJECTS     {  raisecomNotificationLocation,
                   raisecomOpticalTransceiverParameterValue,
                   raisecomOpticalTransceiverParamAlarmStatus  }
    STATUS      current
    DESCRIPTION
        "This notification is sent when the optical module  +3.3V supply Voltage  value increase to above 
         the high alarm threshold or dicrease to under the low alarm threshold.

        This notification may be suppressed under the following
        conditions:
        - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
        "
    ::={ raisecomOpticalTransceiverParamNotifications 25 }

raisecomOpticalTransceiverP3V3supplyVoltageWarningTrap   NOTIFICATION-TYPE
    OBJECTS     {  raisecomNotificationLocation,
                   raisecomOpticalTransceiverParameterValue,
                   raisecomOpticalTransceiverParamAlarmStatus  }
    STATUS      current
    DESCRIPTION
        "This notification is sent when the optical module +3.3V supply Voltage value increase to above 
         the high warning threshold or dicrease to under the low warning threshold.
        This notification may be suppressed under the following
        conditions:
        - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
        "
    ::={ raisecomOpticalTransceiverParamNotifications 26 }
   
raisecomOpticalTransceiverP3V3supplyVoltageWarningNormalTrap   NOTIFICATION-TYPE
    OBJECTS     {  raisecomNotificationLocation,
                   raisecomOpticalTransceiverParameterValue,
                   raisecomOpticalTransceiverParamAlarmStatus  }
    STATUS      current
    DESCRIPTION
        "This notification is sent when the optical module +3.3V supply Voltage value dicrease to
         under the high warning threshold or increase to above the low warning threshold.
        This notification may be suppressed under the following
        conditions:
        - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
        "
    ::={ raisecomOpticalTransceiverParamNotifications 27 }
   
raisecomOpticalTransceiverP3V3supplyVoltageAlarmNormalTrap   NOTIFICATION-TYPE
    OBJECTS     {  raisecomNotificationLocation,
                   raisecomOpticalTransceiverParameterValue,
                   raisecomOpticalTransceiverParamAlarmStatus  }
    STATUS      current
    DESCRIPTION
        "This notification is sent when the optical module +3.3V supply Voltage value dicrease to
         under the high alarm threshold or increase to above the low alarm threshold.

        This notification may be suppressed under the following
        conditions:
        - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
        "
    ::={ raisecomOpticalTransceiverParamNotifications 28 }
   
raisecomOpticalTransceiverP1V8supplyVoltageAlarmTrap   NOTIFICATION-TYPE
    OBJECTS     {  raisecomNotificationLocation,
                   raisecomOpticalTransceiverParameterValue,
                   raisecomOpticalTransceiverParamAlarmStatus  }

    STATUS      current
    DESCRIPTION
        "This notification is sent when the optical module +1.8v supply Voltage value increase to above 
         the high alarm threshold or dicrease to under the low alarm threshold.
         
        This notification may be suppressed under the following
        conditions:
        - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
        "
    ::={ raisecomOpticalTransceiverParamNotifications 29 }
   
raisecomOpticalTransceiverP1V8supplyVoltageWarningTrap   NOTIFICATION-TYPE
    OBJECTS     {  raisecomNotificationLocation,
                   raisecomOpticalTransceiverParameterValue,
                   raisecomOpticalTransceiverParamAlarmStatus  }

    STATUS      current
    DESCRIPTION
        "This notification is sent when the optical module  +1.8v supply Voltage value increase to above 
         the high warning threshold or dicrease to under the low warning threshold.

        This notification may be suppressed under the following
        conditions:
        - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
        "
    ::={ raisecomOpticalTransceiverParamNotifications 30 }
   
raisecomOpticalTransceiverP1V8supplyVoltageWarningNormalTrap   NOTIFICATION-TYPE
    OBJECTS     {  raisecomNotificationLocation,
                   raisecomOpticalTransceiverParameterValue,
                   raisecomOpticalTransceiverParamAlarmStatus  }

    STATUS      current
    DESCRIPTION
        "This notification is sent when the optical module  +1.8v supply Voltage value dicrease to
         under the high warning threshold or increase to above the low warning threshold.

        This notification may be suppressed under the following
        conditions:
        - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
        "
    ::={ raisecomOpticalTransceiverParamNotifications 31 }
   
raisecomOpticalTransceiverP1V8supplyVoltageAlarmNormalTrap   NOTIFICATION-TYPE
    OBJECTS     {  raisecomNotificationLocation,
                   raisecomOpticalTransceiverParameterValue,
                   raisecomOpticalTransceiverParamAlarmStatus  }

    STATUS      current
    DESCRIPTION
        "This notification is sent when the optical module +1.8v supply Voltage value dicrease to
         under the high alarm threshold or increase to above the low alarm threshold.

        This notification may be suppressed under the following
        conditions:
        - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
        "
    ::={ raisecomOpticalTransceiverParamNotifications 32 }
   
raisecomOpticalTransceiverN5V2supplyVoltageAlarmTrap   NOTIFICATION-TYPE
    OBJECTS     {  raisecomNotificationLocation,
                   raisecomOpticalTransceiverParameterValue,
                   raisecomOpticalTransceiverParamAlarmStatus  }

    STATUS      current
    DESCRIPTION
        "This notification is sent when the optical module -5.2v supply Voltage  value increase to above 
         the high alarm threshold or dicrease to under the low alarm threshold.

        This notification may be suppressed under the following
        conditions:
        - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
        "
    ::={ raisecomOpticalTransceiverParamNotifications 33 }

raisecomOpticalTransceiverN5V2supplyVoltageWarningTrap   NOTIFICATION-TYPE
    OBJECTS     {  raisecomNotificationLocation,
                   raisecomOpticalTransceiverParameterValue,
                   raisecomOpticalTransceiverParamAlarmStatus  }

    STATUS      current
    DESCRIPTION
        "This notification is sent when the optical module -5.2v supply Voltage value increase to above 
         the high warning threshold or dicrease to under the low warning threshold.

        This notification may be suppressed under the following
        conditions:
        - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
        "
    ::={ raisecomOpticalTransceiverParamNotifications 34 }
 
raisecomOpticalTransceiverN5V2supplyVoltageWarningNormalTrap   NOTIFICATION-TYPE
    OBJECTS     {  raisecomNotificationLocation,
                   raisecomOpticalTransceiverParameterValue,
                   raisecomOpticalTransceiverParamAlarmStatus  }

    STATUS      current
    DESCRIPTION
        "This notification is sent when the optical module -5.2v supply Voltage value dicrease to
         under the high warning threshold or increase to above the low warning threshold.

        This notification may be suppressed under the following
        conditions:
        - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
        "
    ::={ raisecomOpticalTransceiverParamNotifications 35 }

raisecomOpticalTransceiverN5V2supplyVoltageAlarmNormalTrap   NOTIFICATION-TYPE
    OBJECTS     {  raisecomNotificationLocation,
                   raisecomOpticalTransceiverParameterValue,
                   raisecomOpticalTransceiverParamAlarmStatus  }

    STATUS      current
    DESCRIPTION
        "This notification is sent when the optical module -5.2v supply Voltage value dicrease to
         under the high alarm threshold or increase to above the low alarm threshold.

        This notification may be suppressed under the following
        conditions:
        - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
        "
    ::={ raisecomOpticalTransceiverParamNotifications 36 }
   
raisecomOpticalTransceiverApdBiasVoltageAlarmTrap   NOTIFICATION-TYPE
    OBJECTS     {  raisecomNotificationLocation,
                   raisecomOpticalTransceiverParameterValue,
                   raisecomOpticalTransceiverParamAlarmStatus  }

    STATUS      current
    DESCRIPTION
        "This notification is sent when the optical module APD Bias Voltage value increase to above 
         the high alarm threshold or dicrease to under the low alarm threshold.       
         
        This notification may be suppressed under the following
        conditions:
        - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
        "
    ::={ raisecomOpticalTransceiverParamNotifications 37 }
   
raisecomOpticalTransceiverApdBiasVoltageWarningTrap   NOTIFICATION-TYPE
    OBJECTS     {  raisecomNotificationLocation,
                   raisecomOpticalTransceiverParameterValue,
                   raisecomOpticalTransceiverParamAlarmStatus  }

    STATUS      current
    DESCRIPTION
        "This notification is sent when the optical module APD Bias Voltage  value increase to above 
         the high warning threshold or dicrease to under the low warning threshold.
         
        This notification may be suppressed under the following
        conditions:
        - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
        "
    ::={ raisecomOpticalTransceiverParamNotifications 38 }
   
raisecomOpticalTransceiverApdBiasVoltageWarningNormalTrap   NOTIFICATION-TYPE
    OBJECTS     {  raisecomNotificationLocation,
                   raisecomOpticalTransceiverParameterValue,
                   raisecomOpticalTransceiverParamAlarmStatus  }
    STATUS      current
    DESCRIPTION
        "This notification is sent when the optical module APD Bias Voltage value dicrease to
         under the high warning threshold or increase to above the low warning threshold.

        This notification may be suppressed under the following
        conditions:
        - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
        "
    ::={ raisecomOpticalTransceiverParamNotifications 39 }
   
raisecomOpticalTransceiverApdBiasVoltageAlarmNormalTrap   NOTIFICATION-TYPE
    OBJECTS     {  raisecomNotificationLocation,
                   raisecomOpticalTransceiverParameterValue,
                   raisecomOpticalTransceiverParamAlarmStatus  }

    STATUS      current
    DESCRIPTION
        "This notification is sent when the optical module APD Bias Voltage value dicrease to
         under the high alarm threshold or increase to above the low alarm threshold.


        This notification may be suppressed under the following
        conditions:
        - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
        "
    ::={ raisecomOpticalTransceiverParamNotifications 40 }
   
raisecomOpticalTransceiverP5V0supplyCurrentAlarmTrap   NOTIFICATION-TYPE
    OBJECTS     {  raisecomNotificationLocation,
                   raisecomOpticalTransceiverParameterValue,
                   raisecomOpticalTransceiverParamAlarmStatus  }
    STATUS      current
    DESCRIPTION
        "This notification is sent when the optical module +5.0V supply Current  value increase to above 
         the high alarm threshold or dicrease to under the low alarm threshold.

        This notification may be suppressed under the following
        conditions:
        - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
        "
    ::={ raisecomOpticalTransceiverParamNotifications 41 }
   
raisecomOpticalTransceiverP5V0supplyCurrentWarningTrap   NOTIFICATION-TYPE
    OBJECTS     {  raisecomNotificationLocation,
                   raisecomOpticalTransceiverParameterValue,
                   raisecomOpticalTransceiverParamAlarmStatus  }

    STATUS      current
    DESCRIPTION
        "This notification is sent when the optical module +5.0V supply Current  value increase to above 
         the high warning threshold or dicrease to under the low warning threshold.

        This notification may be suppressed under the following
        conditions:
        - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
        "
    ::={ raisecomOpticalTransceiverParamNotifications 42 }
   
raisecomOpticalTransceiverP5V0supplyCurrentWarningNormalTrap   NOTIFICATION-TYPE
    OBJECTS     {  raisecomNotificationLocation,
                   raisecomOpticalTransceiverParameterValue,
                   raisecomOpticalTransceiverParamAlarmStatus  }

    STATUS      current
    DESCRIPTION
        "This notification is sent when the optical module +5.0V supply Current value dicrease to
         under the high warning threshold or increase to above the low warning threshold.

        This notification may be suppressed under the following
        conditions:
        - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
        "
    ::={ raisecomOpticalTransceiverParamNotifications 43 }

raisecomOpticalTransceiverP5V0supplyCurrentAlarmNormalTrap   NOTIFICATION-TYPE
    OBJECTS     {  raisecomNotificationLocation,
                   raisecomOpticalTransceiverParameterValue,
                   raisecomOpticalTransceiverParamAlarmStatus  }

    STATUS      current
    DESCRIPTION
        "This notification is sent when the optical module +5.0V supply Current value dicrease to
         under the high alarm threshold or increase to above the low alarm threshold.

        This notification may be suppressed under the following
        conditions:
        - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
        "
    ::={ raisecomOpticalTransceiverParamNotifications 44 }
 
raisecomOpticalTransceiverP3V3supplyCurrentAlarmTrap   NOTIFICATION-TYPE
    OBJECTS     {  raisecomNotificationLocation,
                   raisecomOpticalTransceiverParameterValue,
                   raisecomOpticalTransceiverParamAlarmStatus  }

    STATUS      current
    DESCRIPTION
        "This notification is sent when the optical module +3.3V supply Current value increase to above 
         the high alarm threshold or dicrease to under the low alarm threshold.

        This notification may be suppressed under the following
        conditions:
        - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
        "
    ::={ raisecomOpticalTransceiverParamNotifications 45 }

raisecomOpticalTransceiverP3V3supplyCurrentWarningTrap   NOTIFICATION-TYPE
    OBJECTS     {  raisecomNotificationLocation,
                   raisecomOpticalTransceiverParameterValue,
                   raisecomOpticalTransceiverParamAlarmStatus  }

    STATUS      current
    DESCRIPTION
        "This notification is sent when the optical module +3.3V supply Current value increase to above 
         the high warning threshold or dicrease to under the low warning threshold.

        This notification may be suppressed under the following
        conditions:
        - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
        "
    ::={ raisecomOpticalTransceiverParamNotifications 46 }
   
raisecomOpticalTransceiverP3V3supplyCurrentWarningNormalTrap   NOTIFICATION-TYPE
    OBJECTS     {  raisecomNotificationLocation,
                   raisecomOpticalTransceiverParameterValue,
                   raisecomOpticalTransceiverParamAlarmStatus  }

    STATUS      current
    DESCRIPTION
        "This notification is sent when the optical module +3.3V supply Current value dicrease to
         under the high warning threshold or increase to above the low warning threshold.

        This notification may be suppressed under the following
        conditions:
        - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
        "
    ::={ raisecomOpticalTransceiverParamNotifications 47 }
   
raisecomOpticalTransceiverP3V3supplyCurrentAlarmNormalTrap   NOTIFICATION-TYPE
    OBJECTS     {  raisecomNotificationLocation,
                   raisecomOpticalTransceiverParameterValue,
                   raisecomOpticalTransceiverParamAlarmStatus  }

    STATUS      current
    DESCRIPTION
        "This notification is sent when the optical module +3.3V supply Current value dicrease to
         under the high alarm threshold or increase to above the low alarm threshold.

        This notification may be suppressed under the following
        conditions:
        - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
        "
    ::={ raisecomOpticalTransceiverParamNotifications 48 }
   
raisecomOpticalTransceiverP1V8supplyCurrentAlarmTrap   NOTIFICATION-TYPE
    OBJECTS     {  raisecomNotificationLocation,
                   raisecomOpticalTransceiverParameterValue,
                   raisecomOpticalTransceiverParamAlarmStatus  }

    STATUS      current
    DESCRIPTION
        "This notification is sent when the optical module +1.8V supply Current value increase to above 
         the high alarm threshold or dicrease to under the low alarm threshold.

        This notification may be suppressed under the following
        conditions:
        - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
        "
    ::={ raisecomOpticalTransceiverParamNotifications 49 }
   
raisecomOpticalTransceiverP1V8supplyCurrentWarningTrap   NOTIFICATION-TYPE
    OBJECTS     {  raisecomNotificationLocation,
                   raisecomOpticalTransceiverParameterValue,
                   raisecomOpticalTransceiverParamAlarmStatus  }

    STATUS      current
    DESCRIPTION
        "This notification is sent when the optical module +1.8V supply Current value increase to above 
         the high warning threshold or dicrease to under the low warning threshold.

        This notification may be suppressed under the following
        conditions:
        - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
        "
    ::={ raisecomOpticalTransceiverParamNotifications 50 }
   
raisecomOpticalTransceiverP1V8supplyCurrentWarningNormalTrap   NOTIFICATION-TYPE
    OBJECTS     {  raisecomNotificationLocation,
                   raisecomOpticalTransceiverParameterValue,
                   raisecomOpticalTransceiverParamAlarmStatus  }
    STATUS      current
    DESCRIPTION
        "This notification is sent when the optical module +1.8V supply Current  value dicrease to
         under the high warning threshold or increase to above the low warning threshold.

        This notification may be suppressed under the following
        conditions:
        - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
        "
    ::={ raisecomOpticalTransceiverParamNotifications 51 }
   
raisecomOpticalTransceiverP1V8supplyCurrentAlarmNormalTrap   NOTIFICATION-TYPE
    OBJECTS     {  raisecomNotificationLocation,
                   raisecomOpticalTransceiverParameterValue,
                   raisecomOpticalTransceiverParamAlarmStatus  }

    STATUS      current
    DESCRIPTION
        "This notification is sent when the optical module +1.8V supply Current value dicrease to
         under the high alarm threshold or increase to above the low alarm threshold.

        This notification may be suppressed under the following
        conditions:
        - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
        "
    ::={ raisecomOpticalTransceiverParamNotifications 52 }
   
raisecomOpticalTransceiverN5V2supplyCurrentAlarmTrap   NOTIFICATION-TYPE
    OBJECTS     {  raisecomNotificationLocation,
                   raisecomOpticalTransceiverParameterValue,
                   raisecomOpticalTransceiverParamAlarmStatus  }

    STATUS      current
    DESCRIPTION
        "This notification is sent when the optical module -5.2V supply Current value increase to above 
         the high alarm threshold or dicrease to under the low alarm threshold.

        This notification may be suppressed under the following
        conditions:
        - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
        "
    ::={ raisecomOpticalTransceiverParamNotifications 53 }

raisecomOpticalTransceiverN5V2supplyCurrentWarningTrap   NOTIFICATION-TYPE
    OBJECTS     {  raisecomNotificationLocation,
                   raisecomOpticalTransceiverParameterValue,
                   raisecomOpticalTransceiverParamAlarmStatus  }
    STATUS      current
    DESCRIPTION
        "This notification is sent when the optical module  -5.2V supply Current value increase to above 
         the high warning threshold or dicrease to under the low warning threshold.
         
        This notification may be suppressed under the following
        conditions:
        - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
        "
    ::={ raisecomOpticalTransceiverParamNotifications 54 }
 
raisecomOpticalTransceiverN5V2supplyCurrentWarningNormalTrap   NOTIFICATION-TYPE
    OBJECTS     {  raisecomNotificationLocation,
                   raisecomOpticalTransceiverParameterValue,
                   raisecomOpticalTransceiverParamAlarmStatus  }

    STATUS      current
    DESCRIPTION
        "This notification is sent when the optical module  -5.2V supply Current value dicrease to
         under the high warning threshold or increase to above the low warning threshold.

        This notification may be suppressed under the following
        conditions:
        - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
        "
    ::={ raisecomOpticalTransceiverParamNotifications 55 }

raisecomOpticalTransceiverN5V2supplyCurrentAlarmNormalTrap   NOTIFICATION-TYPE
    OBJECTS     {  raisecomNotificationLocation,
                   raisecomOpticalTransceiverParameterValue,
                   raisecomOpticalTransceiverParamAlarmStatus  }

    STATUS      current
    DESCRIPTION
        "This notification is sent when the optical module -5.2V supply Current value dicrease to
         under the high alarm threshold or increase to above the low alarm threshold.

        This notification may be suppressed under the following
        conditions:
        - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
        "
    ::={ raisecomOpticalTransceiverParamNotifications 56 }
   
raisecomOpticalTransceiverTecCurrentAlarmTrap   NOTIFICATION-TYPE
    OBJECTS     {  raisecomNotificationLocation,
                   raisecomOpticalTransceiverParameterValue,
                   raisecomOpticalTransceiverParamAlarmStatus  }

    STATUS      current
    DESCRIPTION
        "This notification is sent when the optical module TecCurrent value increase to above 
         the high alarm threshold or dicrease to under the low alarm threshold.

        This notification may be suppressed under the following
        conditions:
        - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
        "
    ::={ raisecomOpticalTransceiverParamNotifications 57 }
   
raisecomOpticalTransceiverTecCurrentWarningTrap   NOTIFICATION-TYPE
    OBJECTS     {  raisecomNotificationLocation,
                   raisecomOpticalTransceiverParameterValue,
                   raisecomOpticalTransceiverParamAlarmStatus  }

    STATUS      current
    DESCRIPTION
        "This notification is sent when the optical module TecCurrent value increase to above 
         the high warning threshold or dicrease to under the low warning threshold.

        This notification may be suppressed under the following
        conditions:
        - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
        "
    ::={ raisecomOpticalTransceiverParamNotifications 58 }
   
raisecomOpticalTransceiverTecCurrentWarningNormalTrap   NOTIFICATION-TYPE
    OBJECTS     {  raisecomNotificationLocation,
                   raisecomOpticalTransceiverParameterValue,
                   raisecomOpticalTransceiverParamAlarmStatus  }

    STATUS      current
    DESCRIPTION
        "This notification is sent when the optical module TecCurrent value dicrease to
         under the high warning threshold or increase to above the low warning threshold.

        This notification may be suppressed under the following
        conditions:
        - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
        "
    ::={ raisecomOpticalTransceiverParamNotifications 59 }
   
raisecomOpticalTransceiverTecCurrentAlarmNormalTrap   NOTIFICATION-TYPE
    OBJECTS     {  raisecomNotificationLocation,
                   raisecomOpticalTransceiverParameterValue,
                   raisecomOpticalTransceiverParamAlarmStatus  }

    STATUS      current
    DESCRIPTION
        "This notification is sent when the optical module TecCurrent value dicrease to
         under the high alarm threshold or increase to above the low alarm threshold.

        This notification may be suppressed under the following
        conditions:
        - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
        "
    ::={ raisecomOpticalTransceiverParamNotifications 60 }
   
raisecomOpticalTransceiverLaserWavelengthAlarmTrap   NOTIFICATION-TYPE
    OBJECTS     {  raisecomNotificationLocation,
                   raisecomOpticalTransceiverParameterValue,
                   raisecomOpticalTransceiverParamAlarmStatus  }

    STATUS      current
    DESCRIPTION
        "This notification is sent when the optical module laserWavelength value increase to above 
         the high alarm threshold or dicrease to under the low alarm threshold.


        This notification may be suppressed under the following
        conditions:
        - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
        "
    ::={ raisecomOpticalTransceiverParamNotifications 61 }
   
raisecomOpticalTransceiverLaserWavelengthWarningTrap   NOTIFICATION-TYPE
    OBJECTS     {  raisecomNotificationLocation,
                   raisecomOpticalTransceiverParameterValue,
                   raisecomOpticalTransceiverParamAlarmStatus  }
    STATUS      current
    DESCRIPTION
        "This notification is sent when the optical module laserWavelength value increase to above 
         the high warning threshold or dicrease to under the low warning threshold.


        This notification may be suppressed under the following
        conditions:
        - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
        "
    ::={ raisecomOpticalTransceiverParamNotifications 62 }
   
raisecomOpticalTransceiverLaserWavelengthWarningNormalTrap   NOTIFICATION-TYPE
    OBJECTS     {  raisecomNotificationLocation,
                   raisecomOpticalTransceiverParameterValue,
                   raisecomOpticalTransceiverParamAlarmStatus  }
    STATUS      current
    DESCRIPTION
        "This notification is sent when the optical module laserWavelength value dicrease to
         under the high warning threshold or increase to above the low warning threshold.
         
        This notification may be suppressed under the following
        conditions:
        - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
        "
    ::={ raisecomOpticalTransceiverParamNotifications 63 }

raisecomOpticalTransceiverLaserWavelengthAlarmNormalTrap   NOTIFICATION-TYPE
    OBJECTS     {  raisecomNotificationLocation,
                   raisecomOpticalTransceiverParameterValue,
                   raisecomOpticalTransceiverParamAlarmStatus  }
    STATUS      current
    DESCRIPTION
        "This notification is sent when the optical module laserWavelength value dicrease to
         under the high alarm threshold or increase to above the low alarm threshold.

        This notification may be suppressed under the following
        conditions:
        - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
        "
    ::={ raisecomOpticalTransceiverParamNotifications 64 }  
    
    raisecomOpticalTransceiverTxFaultTrap   NOTIFICATION-TYPE
    OBJECTS     {  raisecomOpticalTransceiverTxFaultStatus  }
    STATUS      current
    DESCRIPTION
        "This notification is sent when the SFP optical module occures Tx-fault signal.

        This notification may be suppressed under the following
        conditions:
        - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
        "
    ::={ raisecomOpticalTransceiverParamNotifications 65 }
    
    raisecomOpticalTransceiverTxNormalTrap   NOTIFICATION-TYPE
    OBJECTS     {  raisecomOpticalTransceiverTxFaultStatus }
    STATUS      current
    DESCRIPTION
        "This notification is sent when the SFP optical module cancels the Tx-fault signal.

        This notification may be suppressed under the following
        conditions:
        - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
        "
    ::={ raisecomOpticalTransceiverParamNotifications 66 }
    
END